Monte Carlo N Particle code - Dose distribution of clinical electron beams in inhomogeneous phantoms

被引:5
|
作者
Nedaie, H. A. [1 ]
Mosleh-Shirazi, M. A. [2 ]
Allahverdi, M. [3 ]
机构
[1] Univ Tehran Med Sci, Canc Inst, Canc Res Ctr, Dept Radiotherapy Phys, Tehran, Iran
[2] Shiraz Univ Med Sci, Namazi Hosp, Dept Radiotherapy, Radiotherapy Phys Unit, Shiraz, Iran
[3] Shahid Beheshti Univ, Dept Nucl Engn, Tehran, Iran
关键词
Dose distribution; dosimetry; electron therapy; heterogeneous phantom; Monte Carlo N Particle;
D O I
10.4103/0971-6203.106607
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Electron dose distributions calculated using the currently available analytical methods can be associated with large uncertainties. The Monte Carlo method is the most accurate method for dose calculation in electron beams. Most of the clinical electron beam simulation studies have been performed using non- MCNP [Monte Carlo N Particle] codes. Given the differences between Monte Carlo codes, this work aims to evaluate the accuracy of MCNP4C-simulated electron dose distributions in a homogenous phantom and around inhomogeneities. Different types of phantoms ranging in complexity were used; namely, a homogeneous water phantom and phantoms made of polymethyl methacrylate slabs containing different-sized, low- and high-density inserts of heterogeneous materials. Electron beams with 8 and 15 MeV nominal energy generated by an Elekta Synergy linear accelerator were investigated. Measurements were performed for a 10 cm x 10 cm applicator at a source-to-surface distance of 100 cm. Individual parts of the beam-defining system were introduced into the simulation one at a time in order to show their effect on depth doses. In contrast to the first scattering foil, the secondary scattering foil, X and Y jaws and applicator provide up to 5% of the dose. A 2%/2 mm agreement between MCNP and measurements was found in the homogenous phantom, and in the presence of heterogeneities in the range of 1-3%, being generally within 2% of the measurements for both energies in a "complex" phantom. A full-component simulation is necessary in order to obtain a realistic model of the beam. The MCNP4C results agree well with the measured electron dose distributions.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 50 条
  • [21] A Monte Carlo Dose Calculation Framework for Electron Beams On Varian TrueBeam
    Rodrigues, A.
    Sawkey, D.
    Yin, F.
    Wu, Q.
    MEDICAL PHYSICS, 2014, 41 (06) : 314 - +
  • [22] Monte Carlo dose calculations for phantoms with hip prostheses
    Bazalova, M.
    Coolens, C.
    Cury, F.
    Childs, P.
    Beaulieu, L.
    Verhaegen, F.
    INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [23] Effects of CT based Voxel Phantoms on Dose Distribution Calculated with Monte Carlo Method
    陈朝斌
    黄群英
    吴宜灿
    Plasma Science & Technology, 2005, (02) : 2777 - 2780
  • [24] Effects of CT based voxel phantoms on dose distribution calculated with Monte Carlo method
    Chen, CB
    Huang, QY
    Wu, YC
    PLASMA SCIENCE & TECHNOLOGY, 2005, 7 (02) : 2777 - 2780
  • [25] Evaluation of Eclipse Electron Monte Carlo Dose Calculation Algorithm in Inhomogeneous Medium
    Pokharel, G.
    Rana, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [26] Validation of a commercial TPS based on the VMC++ Monte Carlo code for electron beams: Commissioning and dosimetric comparison with EGSnrc in homogeneous and heterogeneous phantoms
    Ferretti, A.
    Martignano, A.
    Simonato, F.
    Paiusco, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (01): : 25 - 35
  • [27] Monte Carlo calculated fluence correction factors in PMMA and polystyrene phantoms in clinical proton beams
    Palmans, H
    Vynckier, S
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 872 - 875
  • [28] Experimental validation of the DPM Monte Carlo code for photon beam dose calculations in inhomogeneous media
    Chetty, I
    Charland, P
    Tyagi, N
    McShan, D
    Fraass, B
    Bielajew, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1351 - 1351
  • [29] Monte Carlo study of correction factors for the use of plastic phantoms in clinical electron dosimetry
    Araki, Fujio
    MEDICAL PHYSICS, 2007, 34 (11) : 4368 - 4377
  • [30] Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams
    Vandervoort, Eric J.
    Tchistiakova, Ekaterina
    La Russa, Daniel J.
    Cygler, Joanna E.
    MEDICAL PHYSICS, 2014, 41 (02) : 021711