LC SEPARATION AND INDUCED FLUOROMETRIC DETECTION OF RIVASTATIN IN BLOOD-PLASMA

被引:33
|
作者
KROL, GJ [1 ]
BECK, GW [1 ]
RITTER, W [1 ]
LETTIERI, JT [1 ]
机构
[1] PHARMACEUT RES CTR,W-5600 WUPPERTAL 1,GERMANY
关键词
RIVASTATIN; HPLC; FLUORESCENCE INDUCTION; BLOOD PLASMA ASSAY;
D O I
10.1016/0731-7085(93)80113-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An LC procedure suitable for quantitative analysis of pg ml(-1) concentrations of the HMG-CoA reductase inhibitor rivastatin in blood plasma was developed. The procedure involves an extraction step, chromatography on an ODS column, and fluorometric detection of a post-column photolytic decomposition product that was isolated and identified. The achieved quantitation limit (25 pg ml(-1)) facilitated analysis of relatively low rivastatin concentrations in plasma that were observed after 100-300 mu g oral doses of rivastatin. At 25 pg ml(-1) concentration the RSD ranged from 3.6 to 13.5% and mean deviation from the nominal value was 8.0%; at 8 ng ml(-1) the RSD range was 0.7-3.6% while the mean deviation was -1.8%. The concentrations obtained with the LC procedure were compared to the concentrations obtained with a specific but less sensitive capillary GC method and a radioimmunoassay (RIA) procedure. Concentrations obtained with the HPLC and GC procedures agreed within experimental error; the RIA concentrations were about 30% higher.
引用
收藏
页码:1269 / 1275
页数:7
相关论文
共 50 条
  • [41] IMMUNOCHEMICAL DETECTION OF DRIED BLOOD-PLASMA IN HEAT PROCESSED MIXTURES WITH MEAT
    OTTO, W
    SINELL, HJ
    BERLINER UND MUNCHENER TIERARZTLICHE WOCHENSCHRIFT, 1989, 102 (01): : 14 - 18
  • [42] DEVELOPMENT OF A RADIOIMMUNOASSAY FOR THE DETECTION OF DIETHYLSTILBESTROL IN BLOOD-PLASMA AND EDIBLE TISSUES OF CATTLE
    HOFFMANN, B
    LASCHUTZA, W
    ARCHIV FUR LEBENSMITTELHYGIENE, 1980, 31 (03): : 105 - 111
  • [43] LHRH-INDUCED ESTRUS AND BLOOD-PLASMA PROGESTERONE PROFILE IN CATTLE
    DABAS, YPS
    SUD, SC
    ATHEYA, UK
    LAKHCHAURA, BD
    INDIAN JOURNAL OF ANIMAL SCIENCES, 1990, 60 (05): : 536 - 538
  • [44] SEMI-MECHANIZED METHOD FOR FLUOROMETRIC-DETERMINATION OF 5-HYDROXYTRYPTAMINE (SEROTONIN) IN BLOOD-PLASMA AND PLATELETS
    HARDEMAN, MR
    DENUYL, A
    PRINS, HK
    CLINICA CHIMICA ACTA, 1972, 37 (NMAR) : 71 - &
  • [45] PROGESTERONE LEVELS IN PERIPHERICAL BLOOD-PLASMA OF EWES, DURING AN INDUCED CYCLE
    FERRERAS, JC
    ZOOTECHNIA, 1981, 30 (1-3): : 8 - 15
  • [46] BLOOD-PLASMA SEROTONIN CONTENT IN PATIENTS WITH DUST-INDUCED BRONCHITIS
    KOZINETS, IM
    VRACHEBNOE DELO, 1985, (10): : 117 - 119
  • [47] RETINALS AND RETINOLS INDUCED BY ESTROGEN IN THE BLOOD-PLASMA OF XENOPUS-LAEVIS
    AZUMA, M
    IRIE, T
    SEKI, T
    JOURNAL OF EXPERIMENTAL BIOLOGY, 1993, 178 : 89 - 96
  • [48] A passive two-way microfluidic device for low volume blood-plasma separation
    Spigarelli, L.
    Bertana, V
    Marchisio, D.
    Scaltrito, L.
    Ferrero, S.
    Cocuzza, M.
    Marasso, S. L.
    Canavese, G.
    Pirri, C. F.
    MICROELECTRONIC ENGINEERING, 2019, 209 : 28 - 34
  • [49] Novel: Time optimization model for centrifugation process: Application in human blood-plasma separation
    Salim, M. S.
    Abd Malek, M. F.
    Sabri, Naseer
    Noaman, N. M.
    Juni, K. M.
    MEASUREMENT, 2013, 46 (09) : 3568 - 3572
  • [50] HYPERALGESIC RESPONSE OF THE RAT TO BLOOD-PLASMA
    VINEGAR, R
    TRUAX, JF
    SELPH, JL
    JOHNSTON, PR
    FEDERATION PROCEEDINGS, 1985, 44 (05) : 1549 - 1549