LC SEPARATION AND INDUCED FLUOROMETRIC DETECTION OF RIVASTATIN IN BLOOD-PLASMA

被引:33
|
作者
KROL, GJ [1 ]
BECK, GW [1 ]
RITTER, W [1 ]
LETTIERI, JT [1 ]
机构
[1] PHARMACEUT RES CTR,W-5600 WUPPERTAL 1,GERMANY
关键词
RIVASTATIN; HPLC; FLUORESCENCE INDUCTION; BLOOD PLASMA ASSAY;
D O I
10.1016/0731-7085(93)80113-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An LC procedure suitable for quantitative analysis of pg ml(-1) concentrations of the HMG-CoA reductase inhibitor rivastatin in blood plasma was developed. The procedure involves an extraction step, chromatography on an ODS column, and fluorometric detection of a post-column photolytic decomposition product that was isolated and identified. The achieved quantitation limit (25 pg ml(-1)) facilitated analysis of relatively low rivastatin concentrations in plasma that were observed after 100-300 mu g oral doses of rivastatin. At 25 pg ml(-1) concentration the RSD ranged from 3.6 to 13.5% and mean deviation from the nominal value was 8.0%; at 8 ng ml(-1) the RSD range was 0.7-3.6% while the mean deviation was -1.8%. The concentrations obtained with the LC procedure were compared to the concentrations obtained with a specific but less sensitive capillary GC method and a radioimmunoassay (RIA) procedure. Concentrations obtained with the HPLC and GC procedures agreed within experimental error; the RIA concentrations were about 30% higher.
引用
收藏
页码:1269 / 1275
页数:7
相关论文
共 50 条