OPTICAL-PERFORMANCE OF BIFOCAL AND MULTIFOCAL INTRAOCULAR LENSES TESTED WITH A NEW DEVICE

被引:14
|
作者
EISENMANN, D
JACOBI, KW
REINER, J
机构
关键词
D O I
10.1055/s-2008-1045916
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
By means of a new optical device developed by Reiner, an optical implantation' of 6 different bi- and multifocal intraocular lenses (MIOLs) was performed in 20 young healthy subjects, and results were compared with those of a monofocal reference IOL. The following parameters were investigated: distance and near visual acuity, depth of focus and contrast sensitivity. The median of distance visual acuity was 1.0 in all IOLs with the exception of a 7-zone refractive MIOL (0.75). Near acuity without near addition was 1.0 in all MIOL models; through focus curves of all MIOLs showed an increase in depth of focus with a typical two peak course. Contrast sensitivity at high contrasts was reduced for the 7-zone-model, but contrast sensitivity at low contrasts was significantly reduced for all MIOLs, except the 2- and 3-zone refractive models.
引用
收藏
页码:381 / 387
页数:7
相关论文
共 50 条
  • [41] Patients’ dissatisfaction with multifocal intraocular lenses managed by exchange with other multifocal lenses of different optical profiles
    Olena Al-Shymali
    Colm McAlinden
    Jorge L. Alio del Barrio
    Mario Canto-Cerdan
    Jorge L. Alio
    Eye and Vision, 9
  • [42] Patients' dissatisfaction with multifocal intraocular lenses managed by exchange with other multifocal lenses of different optical profiles
    Al-Shymali, Olena
    McAlinden, Colm
    Alio del Barrio, Jorge L.
    Canto-Cerdan, Mario
    Alio, Jorge L.
    EYE AND VISION, 2022, 9 (01)
  • [43] Optical performance with multifocal contact lenses
    Marcos, Susana
    Vedhakrishnan, Shrilekha
    Benedi-Garcia, Clara
    Sawides, Lucie
    Dorronsoro, Carlos
    De Castro, Alberto
    Vinas, Maria
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [44] Simulated in situ optical performance of bifocal contact lenses
    ESSILOR Optique Je Contact, Créteil, France
    OPTOM. VIS. SCI., 7 (532-539):
  • [45] Simulated in situ optical performance of bifocal contact lenses
    Chateau, N
    Baude, D
    OPTOMETRY AND VISION SCIENCE, 1997, 74 (07) : 532 - 539
  • [46] A new device for intraocular lenses explantation
    Perez-Silguero, David
    Rivero-Santana, Amado
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (08) : 1322 - +
  • [47] Optical eye parameters influence on the choice of refraction of monofocal and bifocal intraocular lenses
    Lenkova, G.A.
    Avtometriya, 2001, (05): : 96 - 102
  • [48] An update on new low add multifocal intraocular lenses
    Rojas, Mario J.
    Yeu, Elizabeth
    CURRENT OPINION IN OPHTHALMOLOGY, 2016, 27 (04) : 292 - 297
  • [49] AN OPTICAL-MODEL TO DESCRIBE IMAGE-CONTRAST WITH BIFOCAL INTRAOCULAR LENSES
    ATEBARA, NH
    MILLER, D
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 110 (02) : 172 - 177
  • [50] Methods for investigating optical characteristics of bifocal diffractive-refractive intraocular lenses
    G. A. Lenkova