OPTICAL-PERFORMANCE OF BIFOCAL AND MULTIFOCAL INTRAOCULAR LENSES TESTED WITH A NEW DEVICE

被引:14
|
作者
EISENMANN, D
JACOBI, KW
REINER, J
机构
关键词
D O I
10.1055/s-2008-1045916
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
By means of a new optical device developed by Reiner, an optical implantation' of 6 different bi- and multifocal intraocular lenses (MIOLs) was performed in 20 young healthy subjects, and results were compared with those of a monofocal reference IOL. The following parameters were investigated: distance and near visual acuity, depth of focus and contrast sensitivity. The median of distance visual acuity was 1.0 in all IOLs with the exception of a 7-zone refractive MIOL (0.75). Near acuity without near addition was 1.0 in all MIOL models; through focus curves of all MIOLs showed an increase in depth of focus with a typical two peak course. Contrast sensitivity at high contrasts was reduced for the 7-zone-model, but contrast sensitivity at low contrasts was significantly reduced for all MIOLs, except the 2- and 3-zone refractive models.
引用
收藏
页码:381 / 387
页数:7
相关论文
共 50 条
  • [21] OPTICAL-PERFORMANCE REQUIREMENTS FOR THERMAL IMAGING LENSES
    JENNINGS, JP
    BUSSELLE, FJ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 549 : 79 - 85
  • [22] OPTICAL-PERFORMANCE OF THE SUPERREVERSED INTRAOCULAR-LENS
    LU, C
    SMITH, G
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (03): : 293 - 300
  • [23] Reading performance with a refractive multifocal and a diffractive bifocal intraocular lens
    Richter-Mueksch, S
    Weghaupt, H
    Skorpik, C
    Velikay-Parel, M
    Radner, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (11): : 1957 - 1963
  • [24] Visual performance with accommodating and multifocal intraocular lenses
    Lan, Jie
    Huang, Yu-Sen
    Dai, Yun-Hai
    Wu, Xiao-Ming
    Sun, Jia-Jun
    Xie, Li-Xin
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (02) : 235 - 240
  • [25] COMPARISON OF THE STORZ BIFOCAL ZONAL AND THE 3M DIFFRACTIVE MULTIFOCAL INTRAOCULAR LENSES
    BOESTEN, IE
    BEEKHUIS, WH
    HASSMANN, E
    PAMEYER, JH
    BAARSMA, GS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (04): : 437 - 441
  • [26] Sehen mit bi- und multifokalen IntraokularlinsenVision with bifocal and multifocal intraocular lenses
    K. Kirschfeld
    M.F. Land
    Der Ophthalmologe, 2011, 108 : 1139 - 1144
  • [27] Visual performance with accommodating and multifocal intraocular lenses
    Jie Lan
    Yu-Sen Huang
    Yun-Hai Dai
    Xiao-Ming Wu
    Jia-Jun Sun
    Li-Xin Xie
    International Journal of Ophthalmology, 2017, 10 (02) : 235 - 240
  • [28] Imaging quality of bifocal piggyback intraocular lens versus ReSTOR and TECNIS multifocal lenses
    Artigas, Jose M.
    Felipe, Adelina
    Diaz-Llopis, Manuel
    Garcia-Delpech, Salvador
    Navea, Amparo
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (01) : 71 - 75
  • [29] Assessing the optical performance of multifocal (diffractive) intraocular lenses Author's Reply
    Eppig, Timo
    Langenbucher, Achim
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (02) : 207 - 208
  • [30] Impact of Primary Calcification in Segmented Refractive Bifocal Intraocular Lenses on Optical Performance Including Straylight
    Yildirim, Timur M.
    Labuz, Grzegorz
    Khoramnia, Ramin
    Son, Hyeck-Soo
    Schickhardt, Sonja K.
    Lieberwirth, Ingo
    Knorz, Michael C.
    Auffarth, Gerd U.
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (01) : 20 - 27