OPTICAL-PERFORMANCE OF BIFOCAL AND MULTIFOCAL INTRAOCULAR LENSES TESTED WITH A NEW DEVICE

被引:14
|
作者
EISENMANN, D
JACOBI, KW
REINER, J
机构
关键词
D O I
10.1055/s-2008-1045916
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
By means of a new optical device developed by Reiner, an optical implantation' of 6 different bi- and multifocal intraocular lenses (MIOLs) was performed in 20 young healthy subjects, and results were compared with those of a monofocal reference IOL. The following parameters were investigated: distance and near visual acuity, depth of focus and contrast sensitivity. The median of distance visual acuity was 1.0 in all IOLs with the exception of a 7-zone refractive MIOL (0.75). Near acuity without near addition was 1.0 in all MIOL models; through focus curves of all MIOLs showed an increase in depth of focus with a typical two peak course. Contrast sensitivity at high contrasts was reduced for the 7-zone-model, but contrast sensitivity at low contrasts was significantly reduced for all MIOLs, except the 2- and 3-zone refractive models.
引用
收藏
页码:381 / 387
页数:7
相关论文
共 50 条
  • [1] OPTICAL-PERFORMANCE OF MULTIFOCAL INTRAOCULAR LENSES
    HOLLADAY, JT
    VANDIJK, H
    LANG, A
    PORTNEY, V
    WILLIS, TR
    SUN, R
    OKSMAN, HC
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (04): : 413 - 422
  • [2] OPTICAL-PERFORMANCE OF DECENTERED BIFOCAL CONTACT-LENSES
    WOODS, RL
    SAUNDERS, JE
    PORT, MJA
    OPTOMETRY AND VISION SCIENCE, 1993, 70 (03) : 171 - 184
  • [3] Vision with bifocal and multifocal intraocular lenses
    Kirschfeld, K.
    Land, M. F.
    OPHTHALMOLOGE, 2011, 108 (12): : 1139 - 1144
  • [4] OPTICAL-PERFORMANCE OF DECENTERED MONOFOCAL INTRAOCULAR LENSES
    FAALAND, RW
    GROSSMAN, LW
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (03): : 286 - 292
  • [5] Quantitative performance of bifocal and multifocal intraocular lenses in a model eye - Point spread function in multifocal intraocular lenses
    Pieh, S
    Marvan, P
    Lackner, B
    Hanselmayer, G
    Schmidinger, G
    Leitgeb, R
    Sticker, M
    Hitzenberger, CK
    Fercher, AF
    Shorpik, C
    ARCHIVES OF OPHTHALMOLOGY, 2002, 120 (01) : 23 - 28
  • [6] OPTICAL-PERFORMANCE OF AN ASPHERIC MULTIFOCAL INTRAOCULAR-LENS
    CHRISTIE, B
    NORDAN, L
    CHIPMAN, R
    GUPTA, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (05): : 583 - 591
  • [7] Optical performance of multifocal intraocular lenses
    Jacobi, F. K.
    Kessler, W.
    Held, S.
    OPHTHALMOLOGE, 2007, 104 (03): : 236 - 242
  • [8] Visual and optical performance with hybrid multifocal intraocular lenses
    Madrid-Costa, David
    Cervino, Alejandro
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Montes-Mico, Robert
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2010, 93 (06) : 426 - 440
  • [9] Optical performance of monofocal versus multifocal intraocular lenses
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1817 - 1818
  • [10] Effect of Decentration on the Optical Performance in Multifocal Intraocular Lenses
    Soda, Mitsutaka
    Yaguchi, Shigeo
    OPHTHALMOLOGICA, 2012, 227 (04) : 197 - 204