Development of an Animal Fracture Model for Evaluation of Cement Augmentation Femoroplasty: An In Vitro Biomechanical Study

被引:2
|
作者
Luo, Qiang [1 ]
Lu, William W. [1 ]
Lau, Tak-Wing [1 ]
Leung, Frankie [1 ,2 ]
机构
[1] Univ Hong Kong, Dept Orthopaed & Traumatol, Hong Kong, Hong Kong, Peoples R China
[2] Univ Hong Kong, Shenzhen Hosp, Shenzhen Key Lab Innovat Technol Orthopaed Trauma, Shenzhen, Peoples R China
来源
BIORESEARCH OPEN ACCESS | 2014年 / 3卷 / 02期
关键词
aging; femur fracture; hip fracture; osteoporosis;
D O I
10.1089/biores.2013.0036
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Osteoporotic hip fracture is the most severe kind of fracture with high morbidity and mortality. Patients' ambulation and quality of life are significantly affected by the fracture because only 50% regain their prefracture functional status, even if they undergo surgeries. There are many issues associated with the current preventive methods e.g., cost, side effects, patient compliance, and time for onset of action. Femoroplasty, the injection of bone cement into the proximal femur to augment femoral strength and to prevent fracture, has been an option with great potential. However, until now femoroplasty has remained at the stage of biomechanical testing. No in vivo study has evaluated its safety and effectiveness; there is not even an animal model for such investigations. The objective of this study was to develop a proximal femur fracture goat model that consistently fractures at the proximal femur when subject to vertical load, simulating osteoporotic hip fractures in human. Six pairs of fresh frozen mature Chinese goats' femora were obtained and randomly assigned into two groups. For the experimental group, a cylindrical bone defect was created at the proximal femur, while the control was left untreated. In addition, a configuration to mimic the mechanical axis of the goat femur was developed. When subjected to load along the mechanical axis, all the specimens from the bone defect group experienced femoral neck fractures, while fractures occurred at the femoral neck or other sites of the proximal femur in the control group. The biomechanical property (failure load) of the bone defect specimens was significantly lower than that of the control specimens (p < 0.05). Osteoporotic hip fractures of humans were simulated by a goat fracture model, which may serve as a reference for future femoroplasty studies in vivo. The newly developed configuration simulating a femoral mechanical axis for biomechanical tests was practicable during the study.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 50 条
  • [41] Biomechanical evaluation of fixation strength of conventional and expansive pedicle screws with or without calcium based cement augmentation
    Gao, Mingxuan
    Lei, Wei
    Wu, Zixiang
    Liu, Da
    Shi, Lei
    CLINICAL BIOMECHANICS, 2011, 26 (03) : 238 - 244
  • [42] Finite element evaluation on biomechanical compatibility of osteoporotic vertebral augmentation with cancellous bone granules and bone cement
    Wu, Li-Jun
    Yang, Guo-Jing
    Zhan, Li-Cheng
    Yu, Bin-Feng
    Yiyong Shengwu Lixue/Journal of Medical Biomechanics, 2010, 25 (02): : 79 - 88
  • [43] Biomechanical analysis of cement augmentation techniques on pedicle screw fixation in osteopenic bone: A cadaveric study
    Benson C.D.
    Lansford T.
    Cotton J.
    Burton D.
    Jackson R.S.
    McIff T.
    Spine Deformity, 2014, 2 (1) : 28 - 33
  • [44] The Effect of Screw Length and Bone Cement Augmentation on the Fixation Strength of Iliac Screws A Biomechanical Study
    Zheng, Zhao-Min
    Zhang, Kui-Bo
    Zhang, Jia-Fang
    Yu, Bin-Sheng
    Liu, Hui
    Zhuang, Xin-Ming
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (08): : 545 - 550
  • [45] Augmentation of the screw fixation in the femoral head by cement application through the implant - a biomechanical study.
    Kramer, A
    Angst, M
    Gasser, B
    Ganz, R
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2000, 138 (05): : 464 - 469
  • [46] Biomechanical Evaluation of Spring Ligament Augmentation With the FiberTape Device in a Cadaveric Flatfoot Model
    Aynardi, Michael C.
    Saloky, Kaitlin
    Roush, Evan P.
    Juliano, Paul
    Lewis, Gregory S.
    FOOT & ANKLE INTERNATIONAL, 2019, 40 (05) : 596 - 602
  • [47] THE EFFECT OF RADIATION ON THE FRACTURE REPAIR PROCESS - A BIOMECHANICAL EVALUATION OF A CLOSED FRACTURE IN A RAT MODEL
    MARKBREITER, LA
    PELKER, RR
    FRIEDLAENDER, GE
    PESCHEL, R
    PANJABI, MM
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (02) : 178 - 183
  • [48] Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study
    Wilmes, Benedict
    Panayotidis, Agamemnon
    Drescher, Dieter
    EUROPEAN JOURNAL OF ORTHODONTICS, 2011, 33 (04) : 396 - 401
  • [49] In vitro temperature evaluation during cement augmentation of proximal humerus plate screw tips
    Blazejak, Marek
    Hofmann-Fliri, Ladina
    Buechler, Lorenz
    Gueorguiev, Boyko
    Windolf, Markus
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (10): : 1321 - 1326
  • [50] Distal radius fracture fixation with volar locking plates and additional bone augmentation in osteoporotic bone: a biomechanical study in a cadaveric model
    F. Högel
    S. Mair
    S. Eberle
    P. Weninger
    G. von Oldenburg
    P. Augat
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 51 - 57