Development of an Animal Fracture Model for Evaluation of Cement Augmentation Femoroplasty: An In Vitro Biomechanical Study

被引:2
|
作者
Luo, Qiang [1 ]
Lu, William W. [1 ]
Lau, Tak-Wing [1 ]
Leung, Frankie [1 ,2 ]
机构
[1] Univ Hong Kong, Dept Orthopaed & Traumatol, Hong Kong, Hong Kong, Peoples R China
[2] Univ Hong Kong, Shenzhen Hosp, Shenzhen Key Lab Innovat Technol Orthopaed Trauma, Shenzhen, Peoples R China
来源
BIORESEARCH OPEN ACCESS | 2014年 / 3卷 / 02期
关键词
aging; femur fracture; hip fracture; osteoporosis;
D O I
10.1089/biores.2013.0036
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Osteoporotic hip fracture is the most severe kind of fracture with high morbidity and mortality. Patients' ambulation and quality of life are significantly affected by the fracture because only 50% regain their prefracture functional status, even if they undergo surgeries. There are many issues associated with the current preventive methods e.g., cost, side effects, patient compliance, and time for onset of action. Femoroplasty, the injection of bone cement into the proximal femur to augment femoral strength and to prevent fracture, has been an option with great potential. However, until now femoroplasty has remained at the stage of biomechanical testing. No in vivo study has evaluated its safety and effectiveness; there is not even an animal model for such investigations. The objective of this study was to develop a proximal femur fracture goat model that consistently fractures at the proximal femur when subject to vertical load, simulating osteoporotic hip fractures in human. Six pairs of fresh frozen mature Chinese goats' femora were obtained and randomly assigned into two groups. For the experimental group, a cylindrical bone defect was created at the proximal femur, while the control was left untreated. In addition, a configuration to mimic the mechanical axis of the goat femur was developed. When subjected to load along the mechanical axis, all the specimens from the bone defect group experienced femoral neck fractures, while fractures occurred at the femoral neck or other sites of the proximal femur in the control group. The biomechanical property (failure load) of the bone defect specimens was significantly lower than that of the control specimens (p < 0.05). Osteoporotic hip fractures of humans were simulated by a goat fracture model, which may serve as a reference for future femoroplasty studies in vivo. The newly developed configuration simulating a femoral mechanical axis for biomechanical tests was practicable during the study.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 50 条
  • [21] AUGMENTATION CYSTOPLASTY IN RATS - DEVELOPMENT OF AN ANIMAL-MODEL
    GUAN, ZC
    RICARD, G
    CHARESTBOULE, L
    NEILSON, K
    KIRULUTA, G
    JOURNAL OF UROLOGY, 1990, 144 (02): : 461 - 465
  • [22] Cement augmentation of implantsno general cure in osteoporotic fracture treatment. A biomechanical study on non-displaced femoral neck fractures
    Hofmann-Fliri, Ladina
    Nicolino, Tomas I.
    Barla, Jorge
    Gueorguiev, Boyko
    Richards, R. Geoff
    Blauth, Michael
    Windolf, Markus
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2016, 34 (02) : 314 - 319
  • [23] Biomechanical analysis of cement materials for vertebroplasty using a finite element fracture model
    Wilcox, RK
    PROCEEDINGS OF THE THIRD IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2005, : 67 - 71
  • [24] Tough and injectable fiber reinforced calcium phosphate cement as an alternative to polymethylmethacrylate cement for vertebral augmentation: a biomechanical study
    Schickert, Sonia de Lacerda
    Pinto, Joao Castro
    Jansen, John
    Leeuwenburgh, Sander C. G.
    van den Beucken, Jeroen J. J. P.
    BIOMATERIALS SCIENCE, 2020, 8 (15) : 4239 - 4250
  • [25] An In vitro animal study of the biomechanical responses of anulus fibrosus with aging
    Park, C
    Kim, YJ
    Lee, CS
    An, K
    Shin, HJ
    Lee, CH
    Kim, CH
    Shin, JW
    SPINE, 2005, 30 (10) : E259 - E265
  • [26] An in vitro biomechanical study of bone plate and interlocking nail in a canine diaphyseal femoral fracture model
    Bernarde, A
    Diop, A
    Maurel, N
    Viguier, E
    VETERINARY SURGERY, 2001, 30 (05) : 397 - 408
  • [27] FINITE ELEMENT ANALYSIS OF A MODEL OF SIMULATED VERTEBRAL CEMENT AUGMENTATION: INFLUENCE OF THE REPRESENTATION OF THE SHAPE OF THE CEMENT DOMAIN ON BIOMECHANICAL PARAMETERS
    Li, Yuan
    Lewis, Gladius
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2010, 10 (02) : 291 - 311
  • [28] Sandwich Vertebral Fracture in the Study of Adjacent-level Fracture After Vertebral Cement Augmentation
    Wang, Lijun
    Yang, Huilin
    Shi, Yuanxin
    Luo, Zongping
    Jiang, Weimin
    Bao, Zhaohua
    Chen, Kangwu
    Wang, Genlin
    ORTHOPEDICS, 2012, 35 (08) : E1225 - E1230
  • [29] Biomechanical evaluation of kyphoplasty with calcium phosphate cement in a 2-functional spinal unit vertebral compression fracture model
    Khanna, A. Jay
    Lee, Samuel
    Villarraga, Marta
    Gimbel, Jonathan
    Steffey, Duane
    Schwardt, Jeffrey
    SPINE JOURNAL, 2008, 8 (05): : 770 - 777
  • [30] Biomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: an Animal in Vitro Study
    Ein-Afshar, Mohammad Javad
    Shahrezaee, Mostafa
    Shahrezaee, Mohammad Hossein
    Sharifzadeh, Seyed Reza
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2020, 8 (05): : 605 - 612