IMPROVED MANIPULATOR PERFORMANCE THROUGH LOCAL D-H CALIBRATION

被引:7
|
作者
EVERETT, LJ
LEI, J
机构
[1] Department of Mechanical Engineering, Texas A&M University, Texas, 77843, College Station
来源
JOURNAL OF ROBOTIC SYSTEMS | 1995年 / 12卷 / 07期
关键词
D O I
10.1002/rob.4620120705
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
This article deals with the subject of increasing the positioning accuracy of a manipulator beyond what is typically obtained via Denavit-Hartenberg (D-H) calibration. It is commonly accepted that one method for accomplishing this requires including ''extra'' terms (such as static deflection) in the D-H model. Another technique, which is experimentally verified and quantified in this article, is that of local calibration. Rather than continually introducing more and more modeling terms, we restrict the worlvolume of the manipulator. One contribution of this article is an experimental investigation of local calibration. Most data indicates that local calibration offers advantages and it quantifies that the approximate improvement on one particular PUMA 560 robot is as much as four times better than global calibration. Some data indicates that it is not always true that ''localizing'' the calibration is an improvement. The article also discusses the problem of recognizing bad calibration data. We demonstrate a technique for identifying and removing ''bad'' data. Finally, the article shows that the locality of workvolume must include a consideration of the joint motions as well. For example, it presents results when data is taken with the arm in a single configuration, and in multiple configurations. (C) 1995 John Wiley & Sons, Inc.
引用
收藏
页码:505 / 514
页数:10
相关论文
共 50 条
  • [41] Laboratory D-dimer measurement: Improved agreement between methods through calibration
    Jennings, Ian
    Woods, Timothy A. L.
    Kitchen, Dianne P.
    Kitchen, Steve
    Walker, Isobel D.
    THROMBOSIS AND HAEMOSTASIS, 2007, 98 (05) : 1127 - 1135
  • [42] PALEOTEMPERATURES FROM TREE RINGS AND D-H RATIO OF CELLULOSE AS A BIOCHEMICAL THERMOMETER
    WILSON, AT
    GRINSTED, MJ
    NATURE, 1975, 257 (5525) : 387 - 388
  • [43] Kinematics analysis of lower limb rehabilitation robot based on D-H method
    Jie, Kui
    He, Wangyong
    Gui, Renjie
    2022 41ST CHINESE CONTROL CONFERENCE (CCC), 2022, : 3768 - 3773
  • [44] Fast Kinematic Calibration of a Robotic Manipulator Through a Single Continuous Motion
    Jian, Sheng
    Xiong, Hao
    Wang, Anjia
    Lou, Yunjiang
    JOURNAL OF MECHANISMS AND ROBOTICS-TRANSACTIONS OF THE ASME, 2025, 17 (03):
  • [45] Kinematics Modeling and Analysis of TBM Disc Cutter Based on D-H Matrix
    Pu, Y.
    Liu, J. Q.
    Guo, W.
    ADVANCES IN MATERIALS MANUFACTURING SCIENCE AND TECHNOLOGY XIV, 2012, 697-698 : 692 - 696
  • [46] Robust Calibration Procedure of a Manipulator and a 2D Laser Scanner using a 1D Calibration Target
    Alberts, Jan
    Kleinschmidt, Sebastian P.
    Wagner, Bernardo
    ICINCO: PROCEEDINGS OF THE 16TH INTERNATIONAL CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS, VOL 1, 2019, : 112 - 119
  • [47] How directional are D-H•••phenyl interactions in the solid state (D = C, N, O)?
    Mooibroek, Tiddo J.
    Gamez, Patrick
    CRYSTENGCOMM, 2012, 14 (24): : 8462 - 8467
  • [48] Accuracy Improvement Method of a 3D Laser Scanner Based on the D-H Model
    Chen, Kai
    Zhan, Kai
    Yang, Xiaocong
    Zhang, Da
    SHOCK AND VIBRATION, 2021, 2021
  • [49] Kinematic Calibration of Robot Manipulator using RGB-D Camera
    Jang W.B.
    Lee J.
    Park S.H.
    Chung S.Y.
    Jin M.
    Hwang M.J.
    Journal of Institute of Control, Robotics and Systems, 2023, 29 (03) : 264 - 271
  • [50] Daphniglaucins D-H, J, and K, new alkaloids from Daphniphyllum glaucescens
    Takatsu, H
    Morita, H
    Shen, YC
    Kobayashi, J
    TETRAHEDRON, 2004, 60 (30) : 6279 - 6284