IMPROVED MANIPULATOR PERFORMANCE THROUGH LOCAL D-H CALIBRATION

被引:7
|
作者
EVERETT, LJ
LEI, J
机构
[1] Department of Mechanical Engineering, Texas A&M University, Texas, 77843, College Station
来源
JOURNAL OF ROBOTIC SYSTEMS | 1995年 / 12卷 / 07期
关键词
D O I
10.1002/rob.4620120705
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
This article deals with the subject of increasing the positioning accuracy of a manipulator beyond what is typically obtained via Denavit-Hartenberg (D-H) calibration. It is commonly accepted that one method for accomplishing this requires including ''extra'' terms (such as static deflection) in the D-H model. Another technique, which is experimentally verified and quantified in this article, is that of local calibration. Rather than continually introducing more and more modeling terms, we restrict the worlvolume of the manipulator. One contribution of this article is an experimental investigation of local calibration. Most data indicates that local calibration offers advantages and it quantifies that the approximate improvement on one particular PUMA 560 robot is as much as four times better than global calibration. Some data indicates that it is not always true that ''localizing'' the calibration is an improvement. The article also discusses the problem of recognizing bad calibration data. We demonstrate a technique for identifying and removing ''bad'' data. Finally, the article shows that the locality of workvolume must include a consideration of the joint motions as well. For example, it presents results when data is taken with the arm in a single configuration, and in multiple configurations. (C) 1995 John Wiley & Sons, Inc.
引用
收藏
页码:505 / 514
页数:10
相关论文
共 50 条
  • [31] The properties of weak and strong dihydrogen-bonded D-H•••H-A complexes
    Cybulski, H
    Tyminska, E
    Sadlej, J
    CHEMPHYSCHEM, 2006, 7 (03) : 629 - 639
  • [32] D-H RATIOS OF H-2 IN SOIL GASES AS AN INDICATOR OF FAULT MOVEMENTS
    KITA, I
    MATSUO, S
    WAKITA, H
    NAKAMURA, Y
    GEOCHEMICAL JOURNAL, 1980, 14 (06) : 317 - 320
  • [33] Probabilistic Calibration of a Manipulator and a 2D Laser Scanner
    Alberts, Jan
    Kleinschmidt, Sebastian P.
    Wagner, Bernardo
    2020 IEEE INTERNATIONAL SYMPOSIUM ON SAFETY, SECURITY, AND RESCUE ROBOTICS (SSRR 2020), 2020, : 341 - 347
  • [34] Yezo'otogirins D-H, Acylphloroglucinols and Meroterpenes from Hypericum yezoense
    Tanaka, Naonobu
    Tsuji, Eri
    Kashiwada, Yoshiki
    Kobayashi, Jun'ichi
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2016, 64 (07) : 991 - 995
  • [35] Enhanced 1H-X D-HMQC performance through improved 1H homonuclear decoupling
    Perras, Frederic A.
    Goh, Tian Wei
    Wang, Lin-Lin
    Huang, Wenyu
    Pruski, Marek
    SOLID STATE NUCLEAR MAGNETIC RESONANCE, 2019, 98 : 12 - 18
  • [36] Leonticins D-H, five triterpene saponins from Leontice kiangnanensis
    Chen, M
    Wu, WW
    Nanz, D
    Sticher, O
    PHYTOCHEMISTRY, 1997, 44 (03) : 497 - 504
  • [37] VERY BENT D-H ... A HYDROGEN-BONDS - AN ANGULAR CRITERION
    JASKOLSKI, M
    POLISH JOURNAL OF CHEMISTRY, 1984, 58 (7-9) : 955 - 957
  • [38] CLIMATIC IMPLICATIONS OF D-H RATIO OF HYDROGEN IN C-H GROUPS IN TREE CELLULOSE
    EPSTEIN, S
    YAPP, CJ
    EARTH AND PLANETARY SCIENCE LETTERS, 1976, 30 (02) : 252 - 261
  • [39] THE (D-H)-H-3 AND (D-HE)-HE-3 REACTIONS BELOW 45 KEV
    JARVIS, RG
    ROAF, D
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION A, 1953, 66 (399): : 310 - 310
  • [40] Improved Performance of A Low-Cost PDR System through Sensor Calibration and Analysis
    Kim, Yunki
    Lee, Donghyuk
    Kim, Kijung
    Lee, Jangmyung
    2014 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2014, : 1747 - 1752