Preliminary Monte Carlo study of CZT response to BNCT (n

被引:1
|
作者
Altieri, S. [1 ,2 ]
Fatemi, S. [2 ]
Bortolussi, S. [1 ,2 ]
Magni, C. [1 ,2 ]
Postuma, I. P. [2 ]
Protti, N. [2 ]
机构
[1] Univ Pavia, Dipartimento Fis, Pavia, Italy
[2] INFN, Sez Pavia, Pavia, Italy
关键词
D O I
10.1393/ncc/i2018-18208-3
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Boron Neutron Capture Therapy (BNCT) effectiveness depends on the therapeutic dose delivered in tumour when targeted by a sufficient amount of B-10 atoms and exposed to a proper flux of thermal neutrons. Presently these quantities are measured indirectly. The availability of an in vivo and real time dose monitoring tool would be a tremendous achievement to fully exploit BNCT. To this end, a Single-Photon Emission Computed Tomography (SPECT) can measure the 478 keV gamma-ray emitted after 94% of B-10 capture reactions. Presently, the Italian National Institute of Nuclear Physics (INFN) is supporting the 3CaTS project whose aim is to develop a dedicated BNCT-SPECT based on CdZnTe (CZT) semiconductor detectors. A BNCT-SPECT must operate in a highly intense (n + gamma) radiation field. Thus, it is important to study the response of CZT detectors when working in such challenging conditions. In the present work we focused on three main aspects: i) the spectra of the radiation background expected in an accelerator-based BNCT treatment room; ii) the interaction of the thermal neutrons with cadmium present in the crystal; iii) the estimation of the recorded photon counts spectrum when a 478 keV photon source is simulated inside a tissue equivalent phantom.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Dual-layer collimator for improved spatial resolution in SPECT with CZT camera: an analytical and Monte Carlo study
    Boutaghane, Nasreddine
    Hesse, Michel
    Bouzid, Boualem
    Zaidi, Habib
    Jamar, Francois
    Walrand, Stephan
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (06):
  • [42] A Monte Carlo simulation study for designing collimators for a CZT-based spent nuclear fuel characterization system
    Hong, Wooseong
    Kim, Geehyun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1064
  • [43] A MONTE CARLO STUDY OF ESTIMATORS OF PARAMETERS OF A QUANTAL RESPONSE CURVE
    GNANADES.M
    ANNALS OF MATHEMATICAL STATISTICS, 1966, 37 (03): : 763 - &
  • [44] Monte Carlo study on pulse response of underwater optical channel
    Li, Jing
    Ma, Yong
    Zhou, Qunqun
    Zhou, Bo
    Wang, Hongyuan
    OPTICAL ENGINEERING, 2012, 51 (06)
  • [45] A Monte Carlo simulation and deconvolution study of detector response function
    Feng, Y.
    Lamba, M.
    Elson, H.
    Kassing, W.
    Spitz, H.
    MEDICAL PHYSICS, 2007, 34 (06) : 2406 - 2406
  • [46] Photoconductive response of strained silicon nanowires: A Monte Carlo study
    Shiri, Daryoush
    Verma, Amit
    Khader, Mahmoud M.
    JOURNAL OF APPLIED PHYSICS, 2014, 115 (13)
  • [47] Monte Carlo study of Si diode response in electron beams
    Wang, Lilie L. W.
    Rogers, David W. O.
    MEDICAL PHYSICS, 2007, 34 (05) : 1734 - 1742
  • [48] Photoconductive response of strained silicon nanowires: A Monte Carlo study
    Verma, A. (Amit.Verma@tamuk.edu), 1600, American Institute of Physics Inc. (115):
  • [49] Autoradiography in BNCT: a preliminary study for a novel technique
    Ruffolo, MD
    de la Hoz, AP
    Saint Martin, G
    Cruz, GS
    Bernaola, OA
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 876 - 878
  • [50] Monte Carlo study of carrier transport in n(+)-n-n(+) silicon structure
    Harkar, A
    Sundarrajan, V
    Katale, K
    Shaligram, AD
    Ghaisas, SV
    SEMICONDUCTOR DEVICES, 1996, 2733 : 220 - 222