Preliminary Monte Carlo study of CZT response to BNCT (n

被引:1
|
作者
Altieri, S. [1 ,2 ]
Fatemi, S. [2 ]
Bortolussi, S. [1 ,2 ]
Magni, C. [1 ,2 ]
Postuma, I. P. [2 ]
Protti, N. [2 ]
机构
[1] Univ Pavia, Dipartimento Fis, Pavia, Italy
[2] INFN, Sez Pavia, Pavia, Italy
关键词
D O I
10.1393/ncc/i2018-18208-3
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Boron Neutron Capture Therapy (BNCT) effectiveness depends on the therapeutic dose delivered in tumour when targeted by a sufficient amount of B-10 atoms and exposed to a proper flux of thermal neutrons. Presently these quantities are measured indirectly. The availability of an in vivo and real time dose monitoring tool would be a tremendous achievement to fully exploit BNCT. To this end, a Single-Photon Emission Computed Tomography (SPECT) can measure the 478 keV gamma-ray emitted after 94% of B-10 capture reactions. Presently, the Italian National Institute of Nuclear Physics (INFN) is supporting the 3CaTS project whose aim is to develop a dedicated BNCT-SPECT based on CdZnTe (CZT) semiconductor detectors. A BNCT-SPECT must operate in a highly intense (n + gamma) radiation field. Thus, it is important to study the response of CZT detectors when working in such challenging conditions. In the present work we focused on three main aspects: i) the spectra of the radiation background expected in an accelerator-based BNCT treatment room; ii) the interaction of the thermal neutrons with cadmium present in the crystal; iii) the estimation of the recorded photon counts spectrum when a 478 keV photon source is simulated inside a tissue equivalent phantom.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A GPU-Accelerated Monte Carlo Method for BNCT Dose Calculations
    Wang, Y.
    Li, S.
    Wu, J.
    Ye, Z.
    Tao, L.
    Pei, X.
    Xu, X. G.
    MEDICAL PHYSICS, 2024, 51 (10) : 7748 - 7748
  • [22] Monte Carlo Simulations of the GE Discovery Alcyone CZT SPECT system
    Ljungberg, Michael
    Liu, Chi
    Fan, Peng
    Pretorius, P. Hendrik
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [23] Monte Carlo study for γ+N→π+N at a new compound target
    张玉春
    李玉晓
    李家才
    喻纯旭
    陈鹏
    吴元明
    牛卫平
    张少平
    中国物理C, 2008, (12) : 952 - 956
  • [24] Monte Carlo Simulations of the GE Discovery Alcyone CZT SPECT Systems
    Pretorius, P. Hendrik
    Liu, Chi
    Fan, Peng
    Peterson, Mikael
    Ljungberg, Michael
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (03) : 832 - 839
  • [25] Monte Carlo simulation of CZT-based cardiac SPECT systems
    Liu, Zemei
    Ljungberg, Michael
    Chan, Chung
    Liu, Chi
    Holstensson, Maria
    Hutton, Brian
    Pretorius, P.
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [26] Quantum Monte Carlo study of water molecule: A preliminary investigation
    Benedek, NA
    Yarovsky, I
    Latham, K
    Snook, IK
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2004, 57 (12) : 1229 - 1232
  • [27] Feasibility of Prompt Gamma Ray Detection and Imaging Using CdTe Detectors for BNCT - Monte Carlo Study
    Moktan, H.
    Lee, C.
    Cho, S. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E537 - E538
  • [28] BNCT dosimetry Monte Carlo code system-MCDB and its algorithm
    Laboratory of Computational Physics, Institute of Applied Physics and Computational Mathematics, Beijing 100088, China
    不详
    Qinghua Daxue Xuebao, 2007, SUPPL. 1 (901-906):
  • [29] Monte Carlo optimisation of a BNCT facility for treating brain gliomas at the TAPIRO reactor
    Nava, E
    Burn, KW
    Casalini, L
    Petrovich, C
    Rosi, G
    Sarotto, M
    Tinti, R
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 475 - 481
  • [30] Cell death following BNCT: A theoretical approach based on Monte Carlo simulations
    Ballarini, F.
    Bakeine, J.
    Bortolussi, S.
    Bruschi, P.
    Cansolino, L.
    Clerici, A. M.
    Ferrari, C.
    Protti, N.
    Stella, S.
    Zonta, A.
    Zonta, C.
    Altieri, S.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1745 - 1747