Preliminary Monte Carlo study of CZT response to BNCT (n

被引:1
|
作者
Altieri, S. [1 ,2 ]
Fatemi, S. [2 ]
Bortolussi, S. [1 ,2 ]
Magni, C. [1 ,2 ]
Postuma, I. P. [2 ]
Protti, N. [2 ]
机构
[1] Univ Pavia, Dipartimento Fis, Pavia, Italy
[2] INFN, Sez Pavia, Pavia, Italy
关键词
D O I
10.1393/ncc/i2018-18208-3
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Boron Neutron Capture Therapy (BNCT) effectiveness depends on the therapeutic dose delivered in tumour when targeted by a sufficient amount of B-10 atoms and exposed to a proper flux of thermal neutrons. Presently these quantities are measured indirectly. The availability of an in vivo and real time dose monitoring tool would be a tremendous achievement to fully exploit BNCT. To this end, a Single-Photon Emission Computed Tomography (SPECT) can measure the 478 keV gamma-ray emitted after 94% of B-10 capture reactions. Presently, the Italian National Institute of Nuclear Physics (INFN) is supporting the 3CaTS project whose aim is to develop a dedicated BNCT-SPECT based on CdZnTe (CZT) semiconductor detectors. A BNCT-SPECT must operate in a highly intense (n + gamma) radiation field. Thus, it is important to study the response of CZT detectors when working in such challenging conditions. In the present work we focused on three main aspects: i) the spectra of the radiation background expected in an accelerator-based BNCT treatment room; ii) the interaction of the thermal neutrons with cadmium present in the crystal; iii) the estimation of the recorded photon counts spectrum when a 478 keV photon source is simulated inside a tissue equivalent phantom.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Preliminary Monte Carlo study of coded aperture imaging with a CZT gamma camera system for scintimammography
    Alnafea, M.
    Wells, K.
    Spyrou, N. M.
    Guy, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 122 - 125
  • [2] Monte Carlo Simulation of a CZT Detector
    Chun, Sung Dae
    Park, Se Hwan
    Ha, Jang Ho
    Kim, Han Soo
    Cho, Yoon Ho
    Kang, Sang Mook
    Kim, Yong Kyun
    Hong, Duk Geun
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 549 - 552
  • [3] ORANGE, a Monte Carlo dose engine for BNCT
    van der Marck, SC
    Hogenbirk, A
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 569 - 572
  • [4] Introduction to the Monte Carlo dose engine COMPASS for BNCT
    Wan-Bing Zhong
    Jiang Chen
    Yi-Chiao Teng
    Yuan-Hao Liu
    Scientific Reports, 13
  • [5] Introduction to the Monte Carlo dose engine COMPASS for BNCT
    Zhong, Wan-Bing
    Chen, Jiang
    Teng, Yi-Chiao
    Liu, Yuan-Hao
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [6] AGATE Monte Carlo study on ICRP110 phantoms for BNCT dosimetry evaluation
    Pistone, Daniele
    Bortolussi, Silva
    Fatemi, Setareh
    Marcaccio, Barbara
    Bagnale, Laura
    Pezzi, Cristina
    Paganelli, Marco
    Ramos, Ricardo Luis
    Formicola, Emilia
    Sica, Rosa
    Buompane, Raffaele
    Porzio, Giuseppe
    Manti, Lorenzo
    Gialanella, Lucio
    Vercesi, Valerio
    Postuma, Ian
    APPLIED RADIATION AND ISOTOPES, 2025, 220
  • [7] A PRELIMINARY STUDY OF IN-HOUSE MONTE CARLO SIMULATIONS: AN INTEGRATED MONTE CARLO VERIFICATION SYSTEM
    Mukumoto, Nobutaka
    Tsujii, Katsutomo
    Saito, Susumu
    Yasunaga, Masayoshi
    Takegawa, Hideki
    Yamamoto, Tokihiro
    Numasaki, Hodaka
    Teshima, Teruki
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (02): : 571 - 579
  • [8] Monte Carlo modelling of the influence of boron microdistribution on BNCT microdosimetry
    Hugtenburg, Richard P.
    Baker, Adam E. R.
    Green, Stuart
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S168 - S170
  • [9] Monte Carlo description and validation of the Studsvik BNCT clinical beam
    Giusti, V
    af Rosenschöld, PMM
    Sköld, K
    Montagnini, B
    Kierkegaard, J
    Capala, J
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 145 - 151
  • [10] BNCT: neutron dose evaluation using a Monte Carlo code
    Rossi, F.
    Ono, K.
    Suzuki, M.
    Tanaka, H.
    Morigi, M. P.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2009, 164 (5-6): : 350 - 356