OPTIMIZATION OF FLIP ANGLE FOR T1 DEPENDENT CONTRAST IN MRI

被引:38
|
作者
PELC, NJ
机构
关键词
MRI; FLIP ANGLE; T1; CONTRAST; OPTIMIZATION;
D O I
10.1002/mrm.1910290519
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The flip angle which maximizes contrast between materials with different T1 can be calculated from the root of a cubic expression. A simple closed form expression can be used if contrast is defined in a differential sense and results in only slight contrast loss even with large T1 differences.
引用
收藏
页码:695 / 699
页数:5
相关论文
共 50 条
  • [31] Sensitive MRI detection of internalized T1 contrast agents using magnetization transfer contrast
    Castelli, Daniela Delli
    Ferrauto, Giuseppe
    Di Gregorio, Enza
    Terreno, Enzo
    Aime, Silvio
    NMR IN BIOMEDICINE, 2015, 28 (12) : 1663 - 1670
  • [32] VARIATIONS IN T1 AND T2 DUE TO MRI CONTRAST AGENTS - EFFECT ON IMAGE-CONTRAST
    RAO, NAHK
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 584 - 586
  • [33] Simultaneous proton resonance frequency shift thermometry and T1 measurements using a single reference variable flip angle T1 method
    Svedin, Bryant T.
    Payne, Allison
    Parker, Dennis L.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (05) : 3138 - 3152
  • [34] Optimization and Evaluation of Reference Region Variable Flip Angle (RR-VFA) B1+ and T1 Mapping in the Prostate at 3T
    Rangwala, Novena A.
    Dregely, Isabel
    Wu, Holden H.
    Sung, Kyunghyun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (03) : 751 - 760
  • [35] Silent T1 mapping using the variable flip angle method with B1 correction
    Ljungberg, Emil
    Wood, Tobias
    Solana, Ana Beatriz
    Kolind, Shannon
    Williams, Steven C. R.
    Wiesinger, Florian
    Barker, Gareth J.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 813 - 824
  • [36] Comparison of T1 mapping and fixed T1 method for dynamic contrast-enhanced MRI perfusion in brain gliomas
    Conte, G. M.
    Altabella, L.
    Castellano, A.
    Cuccarini, V.
    Bizzi, A.
    Grimaldi, M.
    Costa, A.
    Caulo, M.
    Falini, A.
    Anzalone, N.
    EUROPEAN RADIOLOGY, 2019, 29 (07) : 3467 - 3479
  • [37] Single breath-hold T1 measurement using low flip angle TrueFISP
    Bokacheva, L
    Huang, AJ
    Chen, Q
    Oesingmann, N
    Storey, P
    Rusinek, H
    Lee, VS
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) : 1186 - 1190
  • [38] Comparison of T1 mapping and fixed T1 method for dynamic contrast-enhanced MRI perfusion in brain gliomas
    G. M. Conte
    L. Altabella
    A. Castellano
    V. Cuccarini
    A. Bizzi
    M. Grimaldi
    A. Costa
    M. Caulo
    A. Falini
    N. Anzalone
    European Radiology, 2019, 29 : 3467 - 3479
  • [39] The Challenge of T1 Contrast Agents for High-Magnetic Field MRI
    Helm, Lothar
    CHIMIA, 2011, 65 (09) : 696 - 698
  • [40] Impact of Uncertainty in T1 Measurements On Quantification of Dynamic Contrast Enhanced MRI
    Aryal, M.
    Cao, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3215 - 3215