OPTIMIZATION OF FLIP ANGLE FOR T1 DEPENDENT CONTRAST IN MRI

被引:38
|
作者
PELC, NJ
机构
关键词
MRI; FLIP ANGLE; T1; CONTRAST; OPTIMIZATION;
D O I
10.1002/mrm.1910290519
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The flip angle which maximizes contrast between materials with different T1 can be calculated from the root of a cubic expression. A simple closed form expression can be used if contrast is defined in a differential sense and results in only slight contrast loss even with large T1 differences.
引用
收藏
页码:695 / 699
页数:5
相关论文
共 50 条
  • [21] Paramagnetic nanoparticle T1 and T2 MRI contrast agents
    Xu, Wenlong
    Kattel, Krishna
    Park, Ja Young
    Chang, Yongmin
    Kim, Tae Jeong
    Lee, Gang Ho
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2012, 14 (37) : 12687 - 12700
  • [22] Task-based optimization of flip angle for fibrosis detection in T1-weighted MRI of liver
    Brand, Jonathan F.
    Furenlid, Lars R.
    Altbach, Maria I.
    Galons, Jean-Philippe
    Bhattacharyya, Achyut
    Sharma, Puneet
    Bhattacharyya, Tulshi
    Bilgin, Ali
    Martin, Diego R.
    JOURNAL OF MEDICAL IMAGING, 2016, 3 (03)
  • [23] Chemistry of Tumour Targeted T1 Based MRI Contrast Agents
    Kamaly, Nazila
    Miller, Andrew D.
    Bell, Jimmy D.
    CURRENT TOPICS IN MEDICINAL CHEMISTRY, 2010, 10 (12) : 1158 - 1183
  • [24] Development of macrocyclic Fe(III) T1 MRI contrast agents
    Asik, Didar
    Snyder, Eric
    Spernyak, Joseph
    Morrow, Janet
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [25] RAPID CALCULATION OF T1 USING VARIABLE FLIP ANGLE GRADIENT REFOCUSED IMAGING
    FRAM, EK
    HERFKENS, RJ
    JOHNSON, GA
    GLOVER, GH
    KARIS, JP
    SHIMAKAWA, A
    PERKINS, TG
    PELC, NJ
    MAGNETIC RESONANCE IMAGING, 1987, 5 (03) : 201 - 208
  • [26] Fat Fraction Bias Correction Using T1 Estimates and Flip Angle Mapping
    Yang, Issac Y.
    Cui, Yifan
    Wiens, Curtis N.
    Wade, Trevor P.
    Friesen-Waldner, Lanette J.
    McKenzie, Charles A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (01) : 217 - 223
  • [27] Enhancing gray-to-white matter contrast in 3T T1 spin-echo brain scans by optimizing flip angle
    Schmitz, BL
    Grön, G
    Brausewetter, F
    Hoffmann, MHK
    Aschoff, AJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (08) : 2000 - 2004
  • [28] Flip angle optimization for quantitative phase contrast MR imaging
    Daniel B Ennis
    Matthew J Middione
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [29] Dynamic T1 functional MRI examinations with use of blood pool contrast agent - an approach to optimization of the technique
    Majos, Agata
    Wolak, Tomasz
    Sapieha, Michal
    Olszycki, Marek
    Bogorodzki, Piotr
    Stefanczyk, Ludomir
    CLINICAL IMAGING, 2011, 35 (05) : 385 - 390
  • [30] Comparison of DCE-MRI parametric mapping using MP2RAGE and variable flip angle T1 mapping
    Bergen, Robert V.
    Ryner, Lawrence
    Essig, Marco
    MAGNETIC RESONANCE IMAGING, 2023, 95 : 103 - 109