Comparison of a Three-Dimensional Numerical Model for Fire Resistance of Axially Loaded Concrete Filled Steel Tubular Columns with Eurocode 4

被引:2
|
作者
Espinos, Ana [1 ]
Ibanez, Carmen [1 ]
Romero, Manuel L. [1 ]
Hospitaler, Antonio [1 ]
机构
[1] Univ Politecn Valencia, Inst Ciencia & Tecnol Hormigon ICITECH, Camino Vera S-N, E-46022 Valencia, Spain
关键词
Fire resistance; Concrete filled tubular column; Finite element analysis; Simple calculation model; Eurocode; 4;
D O I
10.1260/2040-2317.2.2.67
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the behaviour of slender axially loaded square and circular CFT columns exposed to fire is modelled using the finite element analysis package ABAQUS. A realistic sequentially coupled nonlinear thermal-stress analysis is conducted for a series of columns available in the literature. By means of this model, a comparison between fire resistance simulations results and experimental tests found in literature is made. Similarly, simulations results are compared to the Eurocode 4 simplified calculation model predictions. Comparisons show that whereas Eurocode 4 predictions are very conservative for both circular and square section CFT columns, the results obtained from the developed numerical model are much more realistic.
引用
收藏
页码:67 / 79
页数:13
相关论文
共 50 条
  • [31] Numerical analysis of axially loaded concrete-filled steel tubular columns strengthened with CFRP grid-reinforced ECC
    Xia, Zhenhua
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2024,
  • [32] Shape effect on the behaviour of axially loaded concrete filled steel tubular stub columns at elevated temperature
    Dai, X. H.
    Lam, D.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 73 : 117 - 127
  • [33] Load-bearing capacity of axially loaded circular concrete-filled steel tubular columns
    Jegadesh, Sankar
    Jayalekshmi, Selvan
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2016, 169 (07) : 508 - 523
  • [34] Nonlinear analysis of axially loaded circular concrete-filled stainless steel tubular short columns
    Patel, Vipulkumar Ishvarbhai
    Liang, Qing Quan
    Hadi, Muhammad N. S.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 101 : 9 - 18
  • [35] Behavior of Axially Loaded Stirrup Confinement Rectangular Concrete-Filled Steel Tubular Stub Columns
    Liu, Jing
    Wang, Wen-jun
    Ding, Fa-xing
    Zeng, Xin-fa
    Tan, Zhe
    Huang, Yan
    Wang, Bao-quan
    ADVANCES IN CIVIL ENGINEERING, 2019, 2019
  • [36] Behavior and design of axially loaded square concrete-filled double steel tubular slender columns
    Chen, Shicai
    Ahmed, Mizan
    Ci, Junchang
    Chen, Wensu
    Sennah, Khaled
    ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (14) : 2953 - 2965
  • [37] Fire behaviour of axially loaded high-strength concrete-filled circular high-strength steel tubular columns
    Du, Tao
    Liu, Faqi
    Yang, Hua
    Peng, Kang
    ENGINEERING STRUCTURES, 2025, 328
  • [38] FEA on mechanical behavior of axially restrained concrete-filled steel tubular columns subjected to fire
    Liu, Faqi
    Pan, Yanchong
    Yang, Hua
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 : 310 - 317
  • [39] Numerical study of the plasticity effect on the behavior of short steel columns filled with concrete loaded axially
    Chaouche, Yousria Boulmaali-Hacene
    Kouider, Nadia
    Djeghaba, Kamel
    Kebaili, Bachir
    FRATTURA ED INTEGRITA STRUTTURALE-FRACTURE AND STRUCTURAL INTEGRITY, 2022, 16 (62): : 91 - 106
  • [40] Fire performance of concrete filled stainless steel tubular columns
    Han, Lin-Hai
    Chen, Feng
    Liao, Fei-Yu
    Tao, Zhong
    Uy, Brian
    ENGINEERING STRUCTURES, 2013, 56 : 165 - 181