Comparison of a Three-Dimensional Numerical Model for Fire Resistance of Axially Loaded Concrete Filled Steel Tubular Columns with Eurocode 4

被引:2
|
作者
Espinos, Ana [1 ]
Ibanez, Carmen [1 ]
Romero, Manuel L. [1 ]
Hospitaler, Antonio [1 ]
机构
[1] Univ Politecn Valencia, Inst Ciencia & Tecnol Hormigon ICITECH, Camino Vera S-N, E-46022 Valencia, Spain
关键词
Fire resistance; Concrete filled tubular column; Finite element analysis; Simple calculation model; Eurocode; 4;
D O I
10.1260/2040-2317.2.2.67
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the behaviour of slender axially loaded square and circular CFT columns exposed to fire is modelled using the finite element analysis package ABAQUS. A realistic sequentially coupled nonlinear thermal-stress analysis is conducted for a series of columns available in the literature. By means of this model, a comparison between fire resistance simulations results and experimental tests found in literature is made. Similarly, simulations results are compared to the Eurocode 4 simplified calculation model predictions. Comparisons show that whereas Eurocode 4 predictions are very conservative for both circular and square section CFT columns, the results obtained from the developed numerical model are much more realistic.
引用
收藏
页码:67 / 79
页数:13
相关论文
共 50 条
  • [21] Fire resistance of square double-skin concrete-filled steel tubular columns and concrete-filled double steel tubular columns
    Zhu, Hongjie
    Ahmed, Mizan
    Li, Chenliu
    Kong, Xiao
    Chen, Shicai
    Yang, Qingtian
    Ghazali, Habibah
    Liang, Qing Quan
    ENGINEERING STRUCTURES, 2024, 319
  • [22] Numerical analysis of axially loaded circular high strength concrete-filled double steel tubular short columns
    Ahmed, Mizan
    Liang, Qing Quan
    Patel, Vipulkumar Ishvarbhai
    Hadi, Muhammad N. S.
    THIN-WALLED STRUCTURES, 2019, 138 : 105 - 116
  • [23] Effectivness of interior stiffeners on axially loaded concrete-filled square tubular steel columns
    Liu, GY
    Huang, CS
    Yeh, YK
    Weng, YT
    Wang, SH
    Tsai, KC
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 521 - 528
  • [24] Fire resistance of concrete-filled high strength steel tubular columns
    Wang, Ke
    Young, Ben
    THIN-WALLED STRUCTURES, 2013, 71 : 46 - 56
  • [25] Fire Resistance Tests of Concrete-Filled Stainless Steel Tubular Columns
    Ghannam, Mohamed
    Tao, Zhong
    Song, Tian Yi
    Composite Construction in Steel and Concrete VII, 2016, : 468 - 478
  • [26] Shape effect on structural fire behaviour of axially loaded Concrete Filled Tubular (CFT) stub columns
    Dai, X. H.
    Lam, D.
    TUBULAR STRUCTURES XIV, 2012, : 575 - 582
  • [27] Fire resistance analysis of concrete filled double skin steel tubular columns under three-sided fire
    Zhang Y.
    Lv X.
    Liu F.
    Xu Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 : 156 - 162
  • [28] Behavior of axially loaded steel-reinforced concrete-filled square steel tubular stub columns
    Gong, Yongzhi
    Ni, Ming
    Ding, Faxing
    Jiang, Guoshuai
    Yu, Zhiwu
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2014, 35 : 120 - 124
  • [29] Local buckling of steel plate in axially loaded square concrete-filled steel tubular short columns
    Wang, Yu-Yin
    Yang, Yuan-Long
    Zhao, Yi
    Yang, Zheng-Yu
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (SUPPL. 1): : 30 - 34
  • [30] Numerical modeling of axially loaded circular concrete-filled double-skin steel tubular short columns incorporating a new concrete confinement model
    Ahmed, Mizan
    Ci, Junchang
    Yan, Xi-Feng
    Lin, Siqi
    Chen, Shicai
    STRUCTURES, 2021, 30 : 611 - 627