X-RAY EXAMINATIONS OF PERIPHERAL JOINTS - COMPARISON OF DIGITAL LUMINESCENT RADIOGRAPHY (DLR) AND SCREEN-FILM SYSTEM COMBINATIONS

被引:7
|
作者
KRUG, B
FISCHBACH, R
HERRMANN, S
DIETLEIN, M
KUPPER, T
DOLKEN, W
HARNISCHMACHER, U
机构
[1] UNIV COLOGNE, RADIOL DIAGNOST POLIKLIN, W-5000 COLOGNE 41, GERMANY
[2] UNIV COLOGNE, INST MED DOKUMENTAT & STAT, W-5000 COLOGNE 41, GERMANY
关键词
DIGITAL LUMINESCENT RADIOGRAPHY (DLR); SCREEN-FILM SYSTEM COMBINATIONS; EXAMINATION OF PERIPHERAL JOINTS;
D O I
10.1055/s-2008-1032618
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
175 matched skeletal x-ray examinations were carried out by digital luminescent radiography (DLR) and conventional screen-film system combinations. In digital luminescent radiography (DLR) two differently postprocessed images were obtained from one x-ray exposure: A display with low spatial frequency enhancement was opposed to a second display with high edge enhancement. Conventional and digital images were evaluated randomly and separately by four radiologists using a questionnaire. DLR proved to be diagnostically equivalent to the conventional technique except for a diminished visibility of subtle erosions and fissures. As major advantages of DLR maybe pointed out that faulty exposures were avoided by the automatic adjustment of image brightness and that the soft tissue margins could be more easily delineated in displays with high edge enhancement than in conventional radiography. However, digital displays with high edge enhancement did not provide additional diagnostic information and led to artifacts at the edges of metal prostheses.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 50 条
  • [41] EFFECT OF X-RAY-SPECTRUM AND SCREEN-FILM UNSHARPNESS ON X-RAY PATTERN OF A BLOOD-VESSEL PHANTOM
    HAUS, AG
    ROSSMANN, K
    LERCH, IA
    PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (04): : 593 - 593
  • [42] COMPARISON OF STEREOSCOPICALLY ACQUIRED CHEST IMAGES BY USING STORAGE PHOSPHOR RADIOGRAPHY AND AN ASYMMETRIC SCREEN-FILM SYSTEM
    HARTMAN, TE
    AUGHENBAUGH, GL
    BROWN, LR
    HARMS, GF
    KARSELL, PR
    MILLER, WE
    RADIOLOGY, 1995, 197 : 341 - 341
  • [43] COMPARISON OF STEREOSCOPICALLY ACQUIRED CHEST IMAGES WITH USE OF STORAGE PHOSPHOR RADIOGRAPHY AND AN ASYMMETRIC SCREEN-FILM SYSTEM
    HARTMAN, TE
    AUGHENBAUGH, GL
    BROWN, LR
    HARMS, GF
    KARSELL, PR
    MILLER, WE
    RADIOLOGY, 1995, 197 : 525 - 525
  • [44] Edge enhancement effect of vision on X-ray radiographs made using screen-film systems
    Kubota, H
    Asai, Y
    Ozaki, Y
    Arimura, H
    Matsumoto, M
    Kanamori, H
    IMAGING SCIENCE JOURNAL, 2003, 51 (01): : 13 - 20
  • [45] Radiation exposure of the abdominal radiograph using digital luminescence radiography and screen-film system - An animal study.
    Seifert, H
    Schneider, G
    Kubale, R
    Blass, G
    Kramann, B
    Leetz, HK
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (04): : 386 - 391
  • [46] A COMPARISON OF DUAL-ENERGY DIGITAL RADIOGRAPHY AND SCREEN-FILM IMAGING IN THE DETECTION OF SUBTLE INTERSTITIAL PULMONARY-DISEASE
    BARNES, GT
    SABBAGH, EA
    CHAKRABORTY, DP
    NATH, PH
    LUNA, RF
    SANDERS, C
    FRASER, RG
    INVESTIGATIVE RADIOLOGY, 1989, 24 (08) : 585 - 591
  • [47] Contrast-detail comparison of a full-field digital mammography system and a screen-film system
    Rosol, MS
    Niklason, LT
    Venkatakrishnan, V
    Silvenoinnen, H
    Kopans, DB
    Hamberg, LM
    RADIOLOGY, 1999, 213P : 151 - 151
  • [48] Evaluation of the diagnostic value of a computed radiography system by comparison of digital hard copy images with screen-film mammography: results of a prospective clinical trial
    Van Ongeval, C
    Bosmans, H
    Van Steen, A
    Joossens, K
    Celis, V
    Van Goethem, M
    Verslegers, I
    Nijs, K
    Rogge, F
    Marchal, G
    EUROPEAN RADIOLOGY, 2006, 16 (06) : 1360 - 1366
  • [49] A COMPARISON BETWEEN DIGITAL LUMINESCENCE RADIOGRAPHY (DLR) AND CONVENTIONAL FILM-SCREEN TECHNIQUES FOR PULMONARY FOCI - A CLINICAL-EVALUATION
    SCHWERMER, B
    WITTE, G
    SPIELMANN, RP
    NICOLAS, V
    FASSBENDER, T
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 153 (02): : 161 - 166
  • [50] Detection of simulated chest lesions with normal and reduced radiation dose -: Comparison of conventional screen-film radiography and a flat-panel x-ray detector based on amorphous silicon
    Strotzer, M
    Gmeinwieser, JK
    Völk, M
    Fründ, R
    Seitz, J
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 1998, 33 (02) : 98 - 103