PRECOLUMN DERIVATIZATION OF RETINOIC ACID FOR LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE AND COULOMETRIC DETECTION

被引:3
|
作者
ELMANSOURI, S
TOD, M
LECLERCQ, M
PORTHAULT, M
CHALOM, J
机构
[1] HOP AVICENNE,SERV PHARM,F-93009 BOBIGNY,FRANCE
[2] FAC MED ALEXIS CARREL,INST PASTEUR,INSERM,U331,F-69327 LYON,FRANCE
[3] LAB SCI ANALYT,F-69622 VILLEURBANNE,FRANCE
[4] EUROBIO,LES ULIS,FRANCE
关键词
COULOMETRY; FLUOROMETRY; LIQUID CHROMATOGRAPHY; RETINOIC ACID;
D O I
10.1016/0003-2670(94)85029-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Derivatization of the carboxyl function of retinoic acid by fluorescent or electroactive reagents prior to liquid chromatography was studied. Ferrocenylethylamine was synthesized and could be coupled to retinoic acid. The coupling reaction involved activation by diphenylphosphinyl chloride. The reaction was carried out at ambient temperature in 50 min with a yield of ca. 95%. The derivative can be detected by coulometric reduction (+ 100 mV) after on-line coulometric oxidation (+ 400 mV). The limit of detection was 1 pmol of derivative on-column, injected in a volume of 10 mu l, but the limit of quantification was 10 pmol of retinoic acid.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 50 条
  • [21] COLUMN LIQUID-CHROMATOGRAPHY WITH DIODE LASER-INDUCED FLUORESCENCE DETECTION OF CARBOXYLIC-ACIDS AFTER PRECOLUMN DERIVATIZATION
    MANK, AJG
    BEEKMAN, MC
    VELTHORST, NH
    BRINKMAN, UAT
    LINGEMAN, H
    GOOIJER, C
    ANALYTICA CHIMICA ACTA, 1995, 315 (1-2) : 209 - 216
  • [22] ANALYSIS OF PLASMA-CATECHOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION - SIMPLE SAMPLE PREPARATION FOR PRECOLUMN FLUORESCENCE DERIVATIZATION
    KAMAHORI, M
    TAKI, M
    WATANABE, Y
    MIURA, J
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 567 (02): : 351 - 358
  • [23] Measurement of thiols in human plasma using liquid chromatography with precolumn derivatization and fluorescence detection
    Salazar, JF
    Schorr, H
    Herrmann, W
    Herbeth, B
    Siest, G
    Leroy, P
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1999, 37 (12) : 469 - 476
  • [24] PRECOLUMN FLUORESCENCE DERIVATIZATION OF PEPTIDES CONTAINING ARGININE ALDEHYDE MOIETY IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TOMORI, E
    CHROMATOGRAPHIA, 1993, 36 : 105 - 109
  • [25] DETERMINATION OF SUGARS BY LIQUID-CHROMATOGRAPHY WITH POSTCOLUMN CATALYTIC DERIVATIZATION AND FLUORESCENCE DETECTION
    COQUET, A
    HAERDI, W
    AGOSTI, RD
    VEUTHEY, JL
    CHROMATOGRAPHIA, 1994, 38 (1-2) : 12 - 16
  • [26] PRECOLUMN PHENYLISOTHIOCYANATE DERIVATIZATION AND LIQUID-CHROMATOGRAPHY OF AMINO-ACIDS IN FOOD
    HAGEN, SR
    FROST, B
    AUGUSTIN, J
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1989, 72 (06): : 912 - 916
  • [27] DETERMINATION OF NITRITE BY PRECOLUMN DERIVATIZATION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    VERMA, KK
    VERMA, A
    ANALYTICAL LETTERS, 1992, 25 (11) : 2083 - 2093
  • [28] NEW BIOCHEMICAL SEPARATIONS USING PRECOLUMN DERIVATIZATION AND MICROCOLUMN LIQUID-CHROMATOGRAPHY
    NOVOTNY, M
    KARLSSON, KE
    KONISHI, M
    ALASANDRO, M
    JOURNAL OF CHROMATOGRAPHY, 1984, 292 (01): : 159 - 167
  • [29] Determination of homocysteine in plasma by precolumn derivatization-high performance liquid chromatography with fluorescence detection
    Tang Xiufang
    Zhen Qianna
    Fan Zimian
    Feng Chengya
    Ding Min
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (06) : 613 - 617
  • [30] Analysis of palytoxin-like in Ostreopsis cultures by liquid chromatography with precolumn derivatization and fluorescence detection
    Riobo, P.
    Paz, B.
    Franco, J. M.
    ANALYTICA CHIMICA ACTA, 2006, 566 (02) : 217 - 223