A COMPARISON OF MORPHINE-PERPHENAZINE AND MIDAZOLAM ON PREOPERATIVE SEDATION AND ARTERIAL OXYGEN-SATURATION

被引:5
|
作者
HUDES, ET
MARANS, HJ
SHINE, K
SCOTT, AC
HIRANO, GM
机构
[1] Department of Anaesthesia, Peel Memorial Hospital, Brampton, L6W 2Z8, Ont.
关键词
COMPLICATIONS; HYPOXEMIA; MONITORING; OXYGEN; PREMEDICATION; MORPHINE; MIDAZOLAM;
D O I
10.1007/BF03008142
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The effectiveness of midazolam and a mixture of morphine-perphenazine premedication to produce sedation and their effects on preoperative oxygen saturation (SaO2) were examined. Eighty-five patients whose SaO2 measured with a pulse oximeter was > 90% and who were not receiving narcotic sedatives or oxygen were randomized to three groups. Each patient had his SaO2 recorded before premedication with placebo (saline), midazolam 0.08 mg . kg-1 or morphine 0.15 mg . kg-1 with perphenazine 2.5-5.0 mg im. From 30-90 min later, prior to anaesthesia SaO2 was repeated, and a sedation score was obtained by a blinded observer using a seven point scale. Median sedation scores were greater for midazolam (4) than for morphine-perphenazine (2) and placebo (1) (P < 0.0001). As well, there was a decrease in the SaO2 in the morphine-perphenazine group (1.7 +/- 2.7%, P < 0.001) but not in the midazolam and placebo groups (0.1 +/- 2.3%, -0.8 +/- 2.1%). In conclusion midazolam produced greater sedation than morphine-perphenazine and placebo without effect on SaO2 whereas morphine-perphenazine showed a decrease in SaO2 preoperatively.