A COMPARISON OF MORPHINE-PERPHENAZINE AND MIDAZOLAM ON PREOPERATIVE SEDATION AND ARTERIAL OXYGEN-SATURATION

被引:5
|
作者
HUDES, ET
MARANS, HJ
SHINE, K
SCOTT, AC
HIRANO, GM
机构
[1] Department of Anaesthesia, Peel Memorial Hospital, Brampton, L6W 2Z8, Ont.
关键词
COMPLICATIONS; HYPOXEMIA; MONITORING; OXYGEN; PREMEDICATION; MORPHINE; MIDAZOLAM;
D O I
10.1007/BF03008142
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The effectiveness of midazolam and a mixture of morphine-perphenazine premedication to produce sedation and their effects on preoperative oxygen saturation (SaO2) were examined. Eighty-five patients whose SaO2 measured with a pulse oximeter was > 90% and who were not receiving narcotic sedatives or oxygen were randomized to three groups. Each patient had his SaO2 recorded before premedication with placebo (saline), midazolam 0.08 mg . kg-1 or morphine 0.15 mg . kg-1 with perphenazine 2.5-5.0 mg im. From 30-90 min later, prior to anaesthesia SaO2 was repeated, and a sedation score was obtained by a blinded observer using a seven point scale. Median sedation scores were greater for midazolam (4) than for morphine-perphenazine (2) and placebo (1) (P < 0.0001). As well, there was a decrease in the SaO2 in the morphine-perphenazine group (1.7 +/- 2.7%, P < 0.001) but not in the midazolam and placebo groups (0.1 +/- 2.3%, -0.8 +/- 2.1%). In conclusion midazolam produced greater sedation than morphine-perphenazine and placebo without effect on SaO2 whereas morphine-perphenazine showed a decrease in SaO2 preoperatively.
引用
收藏
页码:187 / 190
页数:4
相关论文
共 50 条
  • [21] ARTERIAL OXYGEN-SATURATION DURING INDUCTION OF ANESTHESIA
    THORPE, CM
    GAUNTLETT, IS
    ANAESTHESIA, 1990, 45 (12) : 1012 - 1015
  • [22] STUDIES ON OXYGEN-SATURATION OF PULMONARY ARTERIAL BLOOD
    KLAWUHN, A
    KEUTEL, J
    JEDENAK, P
    HERZ KREISLAUF, 1980, 12 (10): : 461 - 461
  • [23] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY
    STRIEBEL, HW
    STEINHOFF, U
    KRETZ, FJ
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (01): : 8 - 16
  • [24] TECHNICAL REPORT - OXYGEN-SATURATION MONITORING DURING SEDATION FOR CHEMONUCLEOLYSIS
    NEWLAND, CJ
    SPIERS, SPW
    FINLAY, DBL
    CLINICAL RADIOLOGY, 1991, 44 (05) : 352 - 353
  • [25] COMPARISON BETWEEN ARTERIAL AND PULSOXIMETRICALLY DETERMINED OXYGEN-SATURATION IN NEONATAL INTENSIVE THERAPY
    SCHWARZE, R
    WAUER, R
    KOCH, R
    POFAHL, A
    MULLER, C
    ZEITSCHRIFT FUR KLINISCHE MEDIZIN-ZKM, 1991, 46 (10): : 737 - 741
  • [26] ALTERATIONS IN OXYGEN-SATURATION AND VENTILATION AFTER INTRAVENOUS SEDATION FOR PERITONEOSCOPY
    BRADY, CE
    HARKLEROAD, LE
    PIERSON, WP
    ARCHIVES OF INTERNAL MEDICINE, 1989, 149 (05) : 1029 - 1032
  • [27] CHANGES IN OXYGEN-SATURATION USING 2 DIFFERENT SEDATION TECHNIQUES
    WALTON, GM
    BOYLE, CA
    THOMSON, PJ
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1991, 29 (02): : 87 - 89
  • [28] A COMPARISON OF VERTICAL AND HORIZONTAL POSITION EXERCISE ON ARTERIAL OXYGEN-SATURATION IN PULMONARY PATIENTS
    BELL, CW
    DREHSEN, SF
    KASS, I
    BURGHER, LW
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1982, 14 (02): : 132 - 132
  • [29] EVALUATION OF EAR OXIMETRY IN THE MEASUREMENT OF ARTERIAL OXYGEN-SATURATION
    CABLE, JA
    JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION, 1981, 81 (02): : 107 - 112
  • [30] ARTERIAL OXYGEN-SATURATION DURING ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY
    WONG, PYN
    LANE, MR
    HAMILTON, I
    ENDOSCOPY, 1993, 25 (04) : 309 - 310