TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS WITH GIANTURCO COILS

被引:203
|
作者
LLOYD, TR
FEDDERLY, R
MENDELSOHN, AM
SANDHU, SK
BEEKMAN, RH
机构
[1] CS MOTT CHILDRENS HOSP,DEPT PEDIAT,DIV PEDIAT CARDIOL,ANN ARBOR,MI
[2] UNIV MICHIGAN,ANN ARBOR,MI 48109
[3] UNIV ARIZONA,DEPT PEDIAT CARDIOL,TUCSON,AZ 85721
关键词
BRIEF COMMUNICATIONS; OCCLUSIONS; PATENT DUCTUS ARTERIOSUS;
D O I
10.1161/01.CIR.88.4.1412
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Transcatheter occlusion with Gianturco coils has been attempted in a small number of patients with tiny (less-than-or-equal-to 1.5-mm diameter) patent ductus arteriosus, and preliminary results have been encouraging. The present study extends this method to larger ductus sizes and makes recommendations for proper coil size selection. Methods and Results. Coil occlusion was attempted in 24 consecutive patients with patent ductus arteriosus who did not require other cardiac surgery. Median patient age was 4.2 years (8 months to 30 years), and mean ductus diameter was 1.7+/-0.8 mm. Two instances of coil embolization occurred in the first 4 patients, with successful coil retrieval. Based on this experience, we proposed that the coil helical diameter should be twice or more the minimum ductus diameter, with coil length sufficient for three or more loops. With these recommendations, coils were successfully implanted in the subsequent 20 consecutive patients. Of the 22 patients with successful coil implantation, 15 (68%) had no residual shunting, and 7 had trace residual shunting by angiography. The continuous murmur was abolished in all 22 patients. No significant complications occurred, and all patients were discharged within 24 hours of successful coil implantation. No change in the systolic pressure gradient between main and left pulmonary artery or ascending and descending aorta was observed. Conclusions. Transcatheter occlusion of patent ductus arteriosus can be safely and effectively achieved in patients with ductus diameters up to 3.3 mm. Coil occlusion does not cause obstruction to flow in the left pulmonary artery or descending aorta. Coils should be selected to provide a helical diameter twice or more the minimum ductus diameter and a length sufficient for three or more loops.
引用
收藏
页码:1412 / 1420
页数:9
相关论文
共 50 条
  • [31] Transarterial occlusion of patent ductus arteriosus with Gianturco coils in pediatric patients: a preliminary result in central Taiwan
    Lee, ML
    Chaou, WT
    Wang, JK
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 69 (01) : 57 - 63
  • [32] Transcatheter closure of patent ductus arteriosus using coils
    Hijazi, ZM
    Geggel, RL
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (09): : 1279 - &
  • [33] PATENT DUCTUS-ARTERIOSUS - TRANSCATHETER CLOSURE WITH A TRANSVENOUS TECHNIQUE
    SAVELIEV, VS
    PROKUBOVSKI, VI
    KOLODY, SM
    SAVELIEV, SV
    VERIN, VE
    RADIOLOGY, 1992, 184 (02) : 341 - 344
  • [34] TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS IN CHILDREN AND ADULTS
    WILSON, NJ
    NEUTZE, JM
    MAWSON, JB
    CALDER, AL
    NEW ZEALAND MEDICAL JOURNAL, 1993, 106 (960) : 299 - 301
  • [35] COMPARISON OF HOSPITAL CHARGES FOR CLOSURE OF PATENT DUCTUS-ARTERIOSUS BY SURGERY AND BY TRANSCATHETER COIL OCCLUSION
    FEDDERLY, RT
    LLOYD, TR
    MOSCA, RS
    BOVE, EL
    BEEKMAN, RH
    CIRCULATION, 1994, 90 (04) : 642 - 642
  • [36] TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS (PDA) IN PIGLETS
    LOCK, JE
    LUND, GB
    RYSAVY, JA
    LUCAS, RV
    CIRCULATION, 1984, 70 (04) : 457 - 457
  • [37] RESULTS OF TRANSCATHETER CLOSURE OF THE PATENT DUCTUS-ARTERIOSUS WITH THE BOTALLOOCCLUDER
    VERIN, VE
    SAVELIEV, SV
    KOLODY, SM
    PROKUBOVSKI, VI
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) : 1509 - 1514
  • [38] Bioptome assisted simultaneous delivery of multiple coils for transcatheter occlusion of patent ductus arteriosus
    Saxena, A.
    Juneja, R.
    Math, R.
    Roy, A.
    Mahajan, R.
    EUROPEAN HEART JOURNAL, 2006, 27 : 800 - 800
  • [39] Transcatheter closure of the patent ductus arteriosus in adults using the Gianturco coil
    Ing, FF
    Mullins, CE
    Rose, M
    Shapir, Y
    Bierman, FZ
    CLINICAL CARDIOLOGY, 1996, 19 (11) : 875 - 879
  • [40] Transcatheter patent ductus arteriosus closure in an infant using the Gianturco-Grifka Vascular Occlusion Device
    Grifka, RG
    Vincent, JA
    Nihill, MR
    Ing, FF
    Mullins, CE
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (06): : 721 - 723