Correlation of optic nerve sheath diameter with intracranial pressure monitoring in patients with severe traumatic brain injury

被引:11
|
作者
Sahoo, Siddhartha Shankar [1 ]
Agrawal, Deepak [1 ]
机构
[1] All India Inst Med Sci, JPNA Trauma Ctr, Dept Neurosurg, New Delhi 110029, India
来源
INDIAN JOURNAL OF NEUROTRAUMA | 2013年 / 10卷 / 01期
关键词
Intracranial pressure; Ultrasound; TBI; Optic nerve sheath diameter; Severe traumatic brain injury;
D O I
10.1016/j.ijnt.2013.05.010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Aims and objectives: To assess the feasibility and reliability of using optic nerve sheath diameter (ONSD) as an objective measure of intracranial pressure (ICP) in patients of severe head injury. Methods and materials: This prospective study was carried out in Neurosurgery ICU over a 3month period (April-June 2012). All patients with severe traumatic brain injury (admission GCS <= 8) who had ICP monitoring using Codman (R) intraparenchymal transducer had serial bedside ONSD measurements taken by a single neurosurgeon using a 7.5 MHz linear probe on the same ultrasound machine (Sonosite Micromaxx (R)) were enrolled in the study. Patients with significant ocular trauma to either eye were excluded. Results: A total of 20 patients were enrolled during the study period. The mean age was 27 years (range 2-43 years) with M:F ratio of 3:1 and mean GCS of 6 (range 4-8). The mean ONSD in patients with ICP >20 was 6.6 + 0.45mm as compared to 5.9 + 0.57mm in patients with ICP <20 (p = 0.028). The Pearson Correlation Coefficient between ONSD (average of both eyes) and ICP was 0.499 (p = 0.041). A cutoff of 6.3 mm detected ICP >20 mmHg with 100% sensitivity and 72.7% specificity. Conclusion: ONSD is a technically simple, non-invasive method of assessing ICP and correlates well with actual ICP in patients of severe traumatic brain injury. A cutoff of 6.3 mm can be used to plan therapeutic interventions when ICP monitoring is unavailable or contraindicated. Copyright (C) 2013, Neurotrauma Society of India. All rights reserved.
引用
收藏
页码:9 / 12
页数:4
相关论文
共 50 条
  • [31] Optic nerve sheath diameter and intracranial pressure
    Dubourg, Julie
    Javouhey, Etienne
    Messerer, Mahmoud
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 9 (05) : 570 - 571
  • [32] Standardized Ultrasonographic Measurement of Optic Nerve Sheath Diameter in Traumatic Brain Injury Patients
    Graziano, Mario
    Sannino, Ciro
    Mottola, Francesco Ferdinando
    NEUROLOGY INDIA, 2023, 71 (04) : 792 - 792
  • [33] Ultrasonographic Assessment of Optic Nerve Sheath Diameter as a Screening Tool for Intracranial Hypertension in Traumatic Brain Injury
    Lioi, Francesco
    Ramm-Pettersen, Jon
    Fratini, Andrea
    Riva, Camilla
    Colella, Niccolo
    Missori, Paolo
    WORLD NEUROSURGERY, 2024, 192 : E42 - E48
  • [34] Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury (vol 40, pg 1267, 2014)
    Sekhon, Mypinder S.
    Griesdale, Donald E.
    Robba, Chiara
    McGlashan, Nick
    Needham, Edward
    Walland, Katherine
    Shook, Alyssa C.
    Smielewski, Peter
    Czosnyka, Marek
    Gupta, Arun K.
    Menon, David K.
    INTENSIVE CARE MEDICINE, 2015, 41 (01) : 177 - 177
  • [35] Serum TBK1 levels are correlated with inflammation, optic nerve sheath diameter and intracranial pressure in severe traumatic brain injury patients under deep sedation
    Zhuang, Shuilong
    Xu, Qing
    Li, Youfu
    Hu, Ke
    Xia, Zhengcai
    Zhang, Lin
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2023, 32 (04): : 415 - 422
  • [36] RETRACTED: Lateral Ventricular Volume Asymmetry and Optic Nerve Sheath Diameter Predict Intracranial Pressure in Traumatic Brain Injury Patients (Retracted Article)
    Wang, Yang
    Yuan, Ziming
    Zhang, Zuoyan
    Shang, Jiawei
    Li, Mingna
    Wang, Wei
    APPLIED BIONICS AND BIOMECHANICS, 2022, 2022
  • [37] Comparison of ultrasonographic measurement of optic nerve sheath diameter (ONSD) versus direct measurement of intracranial pressure (ICP) in traumatic brain injury patients
    Siranovic, Mladen
    Turkovic, Tihana Magdic
    Gopcevic, Aleksandar
    Kelecic, Mijo
    Kovac, Natasa
    Kovac, Josip
    Rode, Bojan
    Vucic, Marinko
    SIGNA VITAE, 2011, 6 (01) : 33 - 35
  • [38] Ultrasound Guided Optic Nerve Sheath Diameter in Comparison to CT Scan for Assessment of Raised Intracranial Pressure in Adult Traumatic Brain Injury Patients
    Goyal, Arushi
    Palta, Sanjeev
    Saroa, Richa
    Jindal, Swati
    ANESTHESIA AND ANALGESIA, 2024, 139 (06):
  • [39] Predictive Value of Optic Nerve Sheath Diameter for Diagnosis of Intracranial Hypertension in Children With Severe Brain Injury
    Cour-Andlauer, Fleur
    Portefaix, Aurelie
    Wroblewski, Isabelle
    Rabilloud, Muriel
    Bordet, Fabienne
    Cogniat, Berengere
    Didier, Capucine
    Pouyau, Robin
    Valla, Frederic V.
    Kassai-Koupai, Behrouz
    Simeon, Gaelle
    Ginhoux, Tiphanie
    Courtil-Teyssedre, Sonia
    Javouhey, Etienne
    FRONTIERS IN PEDIATRICS, 2022, 10
  • [40] Correlation Between Optic Nerve Sheath Diameter and Intracranial Pressure Based on Ultrasonography
    Pan, Nifang
    Xie, Jie
    He, Jian
    Wen, Shun
    Xu, Chunyang
    Zheng, Feng
    Ye, Hongwei
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2021, 11 (01) : 241 - 246