Correlation of optic nerve sheath diameter with intracranial pressure monitoring in patients with severe traumatic brain injury

被引:11
|
作者
Sahoo, Siddhartha Shankar [1 ]
Agrawal, Deepak [1 ]
机构
[1] All India Inst Med Sci, JPNA Trauma Ctr, Dept Neurosurg, New Delhi 110029, India
来源
INDIAN JOURNAL OF NEUROTRAUMA | 2013年 / 10卷 / 01期
关键词
Intracranial pressure; Ultrasound; TBI; Optic nerve sheath diameter; Severe traumatic brain injury;
D O I
10.1016/j.ijnt.2013.05.010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Aims and objectives: To assess the feasibility and reliability of using optic nerve sheath diameter (ONSD) as an objective measure of intracranial pressure (ICP) in patients of severe head injury. Methods and materials: This prospective study was carried out in Neurosurgery ICU over a 3month period (April-June 2012). All patients with severe traumatic brain injury (admission GCS <= 8) who had ICP monitoring using Codman (R) intraparenchymal transducer had serial bedside ONSD measurements taken by a single neurosurgeon using a 7.5 MHz linear probe on the same ultrasound machine (Sonosite Micromaxx (R)) were enrolled in the study. Patients with significant ocular trauma to either eye were excluded. Results: A total of 20 patients were enrolled during the study period. The mean age was 27 years (range 2-43 years) with M:F ratio of 3:1 and mean GCS of 6 (range 4-8). The mean ONSD in patients with ICP >20 was 6.6 + 0.45mm as compared to 5.9 + 0.57mm in patients with ICP <20 (p = 0.028). The Pearson Correlation Coefficient between ONSD (average of both eyes) and ICP was 0.499 (p = 0.041). A cutoff of 6.3 mm detected ICP >20 mmHg with 100% sensitivity and 72.7% specificity. Conclusion: ONSD is a technically simple, non-invasive method of assessing ICP and correlates well with actual ICP in patients of severe traumatic brain injury. A cutoff of 6.3 mm can be used to plan therapeutic interventions when ICP monitoring is unavailable or contraindicated. Copyright (C) 2013, Neurotrauma Society of India. All rights reserved.
引用
收藏
页码:9 / 12
页数:4
相关论文
共 50 条
  • [21] Optic nerve sheath diameter by ultrasound is a good screening tool for high intracranial pressure in traumatic brain injury
    Altayar, Ashraf S.
    Abouelela, Amr Z.
    Abdelshafey, Eslam E.
    Mohammed, Khaled S. S.
    Hassan, Ahmed A.
    Khattab, Mohammed A.
    Alhabashy, Walid
    Gomaa, Wael
    Mohammed, Amr F.
    Umerani, Muhammad S.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2021, 190 (01) : 387 - 393
  • [22] Ratio of Optic Nerve Sheath Diameter to Eyeball Transverse Diameter by Ultrasonography to Predict Raised Intracranial Pressure in Traumatic Brain Injury
    Vitiello, Livio
    De Bernardo, Maddalena
    Rosa, Nicola
    NEUROCRITICAL CARE, 2019, 31 (03) : 592 - 593
  • [23] Ratio of Optic Nerve Sheath Diameter to Eyeball Transverse Diameter by Ultrasonography to Predict Raised Intracranial Pressure in Traumatic Brain Injury
    Livio Vitiello
    Maddalena De Bernardo
    Nicola Rosa
    Neurocritical Care, 2019, 31 : 592 - 593
  • [24] Intracranial Pressure Assessment in Traumatic Head Injury with Hemorrhage Via Optic Nerve Sheath Diameter
    Vaiman, Michael
    Sigal, Tal
    Kimiagar, Itzhak
    Bekerman, Inessa
    JOURNAL OF NEUROTRAUMA, 2016, 33 (23) : 2147 - 2153
  • [25] Optic nerve sheath measurement and raised intracranial pressure in paediatric traumatic brain injury
    Agrawal, S.
    Brierley, J.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2012, 38 (01) : 75 - 77
  • [26] Optic nerve sheath measurement and raised intracranial pressure in paediatric traumatic brain injury
    S. Agrawal
    J. Brierley
    European Journal of Trauma and Emergency Surgery, 2012, 38 : 75 - 77
  • [27] Osteopathic Manipulative Treatment to Optimize the Glymphatic Environment in Severe Traumatic Brain Injury Measured With Optic Nerve Sheath Diameter, Intracranial Pressure Monitoring, and Neurological Pupil Index
    Kashyap, Samir
    Brazdzionis, James
    Savla, Paras
    Berry, James A.
    Farr, Saman
    Patchana, Tye
    Majeed, Gohar
    Ghanchi, Hammad
    Bowen, Ira
    Wacker, Margaret Rose
    Miulli, Dan E.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (03)
  • [28] Correlation of Positive End-Expiratory and Intracranial Pressure Using the Ultrasonographic-Guided Measurement of Optic Nerve Sheath Diameter in Traumatic Brain Injury Patients
    Gupta, Neha
    Singh, Vipin K.
    Jafa, Shobhna
    NEUROLOGY INDIA, 2021, 69 (06) : 1670 - 1674
  • [29] Relationship of the optic nerve sheath diameter and repeated invasive intracranial pressure measures in traumatic brain injury patients; a diagnostic accuracy study
    Mehrpour, Somayeh
    Najafi, Atabak
    Ahmadi, Arezoo
    Zarei, Tayebeh
    Pleqi, Vasili
    Basiri, Kamal
    Komlakh, Khalil
    Abdollahi, Hamed
    Emami, Kaveh Hedayati
    FRONTIERS IN EMERGENCY MEDICINE, 2022, 6 (01):
  • [30] Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure
    Kimberly, Heidi Harbison
    Shah, Sachita
    Marill, Keith
    Noble, Vicki
    ACADEMIC EMERGENCY MEDICINE, 2008, 15 (02) : 201 - 204