RAPID FLUORESCENCE CONCENTRATION IMMUNOASSAY FOR DETECTION OF SALMONELLAE IN CHICKEN SKIN RINSE WATER

被引:5
|
作者
TSAI, HCS [1 ]
SLAVIK, MF [1 ]
机构
[1] UNIV ARKANSAS,DEPT POULTRY SCI,FAYETTEVILLE,AR 72701
关键词
D O I
10.4315/0362-028X-57.3.190
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Salmonellae in chicken carcass rinse water or enrichment broth were detected with a fluorescence concentration immunoassay (FCIA) using intact salmonellae cells as the reacting particles. Sample solutions and reagents were added to a 96-well fluoricon assay plate and incubated 30 min in the chamber of a fluorescence concentration analyzer at room temperature. The bound and free components were separated by automated vacuum filtration and washings through the membrane filters equipped at the bases of the wells. The fluorescent signals were concentrated through vacuum filtration and were read at a wavelength of 485/535 nm. A cut-off value of the arbitrary fluorescence units was calculated by adding. two standard deviations to the mean value of the negative control. When the arbitrary fluorescence units of a sample were above the cut-off value, it was scored positive indicating the presence of salmonellae in the test suspensions. It was found the FCIA method could detect salmonellae at 1.25 x 10(4) cells per ml in pure culture and was specific enough to screen salmonellae from four types of common chicken carcass contaminating bacteria. By coupling with 18-h direct enrichment in selenite cystine broth of the whole carcass rinse, the detection of salmonellae in chicken carcass rinse water was accomplished in less than 24 h.
引用
收藏
页码:190 / 194
页数:5
相关论文
共 50 条
  • [21] Coupling of immunomagnetic separation and polymerase chain reaction for the rapid detection of salmonellae in minced meat and chicken giblets
    Erol, I
    Kleer, J
    Hildebrandt, G
    Yurtyeri, A
    BERLINER UND MUNCHENER TIERARZTLICHE WOCHENSCHRIFT, 1999, 112 (03): : 100 - 103
  • [22] AN EVALUATION OF A COMMERCIALLY AVAILABLE ENZYME-IMMUNOASSAY TEST FOR THE RAPID DETECTION OF SALMONELLAE IN FOOD AND ENVIRONMENTAL-SAMPLES
    HARFORD, JP
    EPIDEMIOLOGY AND INFECTION, 1987, 99 (01): : 127 - 136
  • [23] Quantum Dot Nanobeads Based Fluorescence Immunoassay for the Quantitative Detection of Sulfamethazine in Chicken and Milk
    Wei, Daixian
    Liu, Jintao
    Wang, Zexiang
    Zhou, Shu
    Wang, Suhua
    Tong, Weipeng
    Peng, Juan
    SENSORS, 2021, 21 (19)
  • [24] Detection of skin tumors on chicken carcasses using hyperspectral fluorescence imaging
    Kim, I.
    Kim, M.S.
    Chen, Y.R.
    Kong, S.G.
    Transactions of the American Society of Agricultural Engineers, 2004, 47 (05): : 1785 - 1792
  • [25] Detection of skin tumors on chicken carcasses using hyperspectral fluorescence imaging
    Kim, I
    Kim, MS
    Chen, YR
    Kong, SG
    TRANSACTIONS OF THE ASAE, 2004, 47 (05): : 1785 - 1792
  • [26] Rapid detection of Campylobacter jejuni in chicken rinse water by melting-peak analysis of amplicons in real-time polymerase chain reaction
    Cheng, ZH
    Griffiths, MW
    JOURNAL OF FOOD PROTECTION, 2003, 66 (08) : 1343 - 1352
  • [27] DETECTION OF ANTIBODY TO BORDETELLA AVIUM USING A PARTICLE CONCENTRATION FLUORESCENCE IMMUNOASSAY (PCFIA)
    BLORE, PJ
    SLAVIK, MF
    NEIGHBOR, NK
    AVIAN DISEASES, 1991, 35 (04) : 756 - 760
  • [28] THE USE OF PARTICLE CONCENTRATION FLUORESCENCE IMMUNOASSAY FOR THE DETECTION OF BACTERIAL SURFACE-ANTIGENS
    DAWSON, M
    JOLLEY, ME
    BETHELL, DR
    HYBRIDOMA, 1984, 3 (01): : 80 - 80
  • [29] IMMUNOASSAY DETECTION OF DRUGS IN RACING HORSES .8. DETECTION OF COCAINE IN EQUINE BLOOD AND URINE BY PARTICLE CONCENTRATION FLUORESCENCE IMMUNOASSAY
    PRANGE, CA
    BROCKUS, C
    WIE, S
    CHUNG, RA
    BRECHT, JM
    CONNER, JC
    DAHL, PA
    LEWIS, EL
    MCDONALD, J
    KALITA, S
    OZOG, FJ
    GREEN, MT
    KWIATKOWSKI, S
    GOODMAN, JP
    STURMA, L
    STANLEY, SD
    YANG, JM
    WOOD, T
    HENRY, P
    WECKMAN, TJ
    WOODS, WE
    WATT, DS
    TAI, HH
    CHANG, SL
    BLAKE, JW
    TOBIN, T
    RESEARCH COMMUNICATIONS IN SUBSTANCES OF ABUSE, 1989, 10 (01) : 1 - 14
  • [30] Rapid detection of cardioactive bufalin toxicity using fluorescence polarization immunoassay for digitoxin
    Dasgupta, A
    Datta, P
    THERAPEUTIC DRUG MONITORING, 1998, 20 (01) : 104 - 108