Rapid detection of cardioactive bufalin toxicity using fluorescence polarization immunoassay for digitoxin

被引:10
|
作者
Dasgupta, A
Datta, P
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Pathol & Lab Med, Houston, TX 77030 USA
[2] Chiron Diagnost, Walpole, ME USA
关键词
bufalin; fluorescence polarization; digitoxin;
D O I
10.1097/00007691-199802000-00019
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Intoxication caused by digitalis-like substances after ingestion of cooked toad soup has been reported. Bufalin, a cardioactive compound, is found in toad. Bufalin is also found in many Chinese medicines. Earlier reports demonstrated cross reactivity of bufalin with fluorescence polarization immunoassay for digoxin. In this report, the authors demonstrated a significantly higher cross reactivity of bufalin with the fluorescence polarization assay for digitoxin. They supplemented aliquots of normal plasma that had various concentrations of bufalin (1 to 50 ng/ml) from a local blood bank and measured apparent digitoxin concentrations using fluorescence polarization immunoassay and chemiluminescent assays (ACS digitoxin) for digitoxin. They measured apparent digoxin and digitoxin concentrations using fluorescence polarization, microparticle enzyme immunoassay, and chemiluminescent assays for digitoxin. They observed apparent digitoxin or digoxin concentrations in sera supplemented with bufalin only with the fluorescence polarization assays. For example, the apparent digitoxin concentration observed in a serum supplemented with 25 ng/ml of bufalin was 24.3 ng/ml of digitoxin equivalent. The apparent digoxin concentration observed in the same specimen was 1.33 ng/ml digoxin equivalent. Bufalin caused positive interference in serum digoxin or digitoxin measurements in specimens containing digoxin or digitoxin when concentrations were measured by fluorescence polarization assays. In contrast, bufalin lowered the measured digoxin concentrations in serum pools containing digoxin when digoxin concentrations were measured by the microparticle enzyme immunoassay. The authors conclude that bufalin toxicity can be rapidly detected by the fluorescence polarization assay for digitoxin.
引用
收藏
页码:104 / 108
页数:5
相关论文
共 50 条
  • [1] A FLUORESCENCE POLARIZATION IMMUNOASSAY (FPIA) FOR THE QUANTITATION OF DIGITOXIN
    DODGE, RH
    HOCKERMAN, GJ
    WANG, PP
    MILLER, RE
    KAZLAUSKAS, VP
    BENNETT, LG
    CLINICAL CHEMISTRY, 1984, 30 (06) : 1013 - 1013
  • [2] Rapid detection of oleander poisoning using fluorescence polarization immunoassay for digitoxin - Effect of treatment with digoxin-specific fab antibody fragment (ovine)
    Dasgupta, A
    Hart, AP
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1997, 108 (04) : 411 - 416
  • [3] Fluorescence Polarization Immunoassay in the Detection of Brucella
    Li, Peng
    Geng, Tao
    Wu, HaiBin
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 2953 - 2957
  • [4] EVALUATION OF A RAPID FLUORESCENCE POLARIZATION IMMUNOASSAY FOR DIGOXIN
    ERICKSON, K
    GREEN, PJ
    HERNANDEZ, P
    CARABALLO, HJ
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1239 - 1239
  • [5] A Sensitive Fluorescence Polarization Immunoassay for the Rapid Detection of Okadaic Acid in Environmental Waters
    Hendrickson, Olga D.
    Mukhametova, Liliya I.
    Zvereva, Elena A.
    Zherdev, Anatoly V.
    Eremin, Sergei A.
    BIOSENSORS-BASEL, 2023, 13 (04):
  • [6] Rapid detection of anti-H5 avian influenza virus antibody by fluorescence polarization immunoassay using a portable fluorescence polarization analyzer
    Nishiyama, Keine
    Takeda, Yohei
    Maeki, Masatoshi
    Ishida, Akihiko
    Tani, Hirofumi
    Shigemura, Koji
    Hibara, Akihide
    Yonezawa, Yutaka
    Imai, Kunitoshi
    Ogawa, Haruko
    Tokeshi, Manabu
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 316
  • [7] RAPID QUANTIFICATION OF PENTOBARBITAL IN SERUM BY FLUORESCENCE POLARIZATION IMMUNOASSAY
    LI, PK
    LEE, JT
    SCHREIBER, RM
    CLINICAL CHEMISTRY, 1984, 30 (02) : 307 - 308
  • [8] A FLUORESCENCE POLARIZATION IMMUNOASSAY FOR DETECTION OF TRICYCLIC ANTIDEPRESSANTS
    HU, HY
    WALTERS, R
    RADEN, D
    KIANG, W
    SIMPSON, J
    BACKES, D
    CLINICAL CHEMISTRY, 1985, 31 (06) : 940 - 940
  • [9] A Simple, Sensitive, Rapid and Specific Detection Method for Bisphenol A based on Fluorescence Polarization Immunoassay
    Wu, Xiaoling
    Wang, Libing
    Ma, Wei
    Zhu, Yingyue
    Xu, Liguang
    Kuang, Hua
    Xu, Chuanlai
    IMMUNOLOGICAL INVESTIGATIONS, 2012, 41 (01) : 38 - 50
  • [10] Rapid fluorescence polarization immunoassay for the mycotoxin deoxynivalenol in wheat
    Maragos, CM
    Plattner, RD
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (07) : 1827 - 1832