BIOCOMPATIBILITY OF EXTRACORPOREAL-CIRCULATION - INVITRO COMPARISON OF HEPARIN-COATED AND UNCOATED OXYGENATOR CIRCUITS

被引:0
|
作者
VIDEM, V
MOLLNES, TE
GARRED, P
SVENNEVIG, JL
机构
[1] UNIV OSLO,NATL HOSP,INST IMMUNOL & RHEUMATOL,OSLO 3,NORWAY
[2] UNIV OSLO,ULLEVAL HOSP,DEPT SURG,OSLO 1,NORWAY
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Oxygenator/tubing sets coated with endpoint-attached heparin were compared to uncoated sets in a dynamic model of extracorporeal circulation. Biocompatibility was assessed by evaluations of complement activation and platelet loss. The median concentration of C3 activation products increased gradually from 12 AU/ml at baseline to 65 AU/ml after 120 minutes in the uncoated sets and from 12 AU/ml to 19 AU/ml after 120 minutes in the coated sets (p < 0.002). The median concentration of the terminal complement complex in the uncoated sets increased gradually from 3.1 AU/ml at baseline to 18.2 AU/ml after 120 minutes. In the coated sets the terminal complement complex reached a peak of 12.0 AU/ml at 15 minutes and returned to baseline values at 60 minutes. Median platelet loss at 120 minutes was 166 X 10(9) in the uncoated and 21 X 10(9) in the coated sets (p < 0.01). Heparin coating thus improved biocompatibility by reducing both complement activation and platelet loss.
引用
收藏
页码:654 / 660
页数:7
相关论文
共 50 条
  • [31] Clinical study of biocompatibility between open and closed heparin-coated cardiopulmonary bypass circuits
    Hiroyuki Tanaka
    Takanori Oshiyama
    Takashi Narisawa
    Takanobu Mori
    Mikio Masuda
    Daijirou Kishi
    Takashi Kitou
    Shingo Miyazima
    Journal of Artificial Organs, 2003, 6 (4) : 245 - 252
  • [32] Biocompatibility reflected by haemostasis variables during cardiopulmonary bypass using heparin-coated circuits
    Borowiec, J
    Bagge, L
    Saldeen, T
    Thelin, S
    THORACIC AND CARDIOVASCULAR SURGEON, 1997, 45 (04): : 163 - 167
  • [33] EXTRACORPOREAL LUNG ASSIST WITH HEPARIN-COATED SYSTEMS
    ROSSAINT, R
    SLAMA, K
    LEWANDOWSKI, K
    STREICH, R
    HENIN, P
    HOPFE, T
    BARTH, H
    NIENHAUS, M
    WEIDEMANN, H
    LEMMENS, P
    FUCHS, J
    FALKE, KJ
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (01): : 29 - 34
  • [34] Clinical outcome after coronary surgery with heparin-coated extracorporeal circuits for cardiopulmonary bypass
    Baufreton, Christophe
    Le Besnerais, Paul
    Jansen, Piet
    Mazzucotelli, Jean Philippe
    Wildevuur, Charles R. H.
    Loisance, Daniel Y.
    PERFUSION-UK, 1996, 11 (06): : 437 - 443
  • [35] PROLONGED EXTRACORPOREAL-CIRCULATION USING A MODIFIED BUBBLE-OXYGENATOR
    POKAR, H
    BLEESE, N
    DEKKERS, R
    LUTZ, G
    POLONIUS, MJ
    THORACIC AND CARDIOVASCULAR SURGEON, 1979, 27 : 29 - 30
  • [36] Comparison of two heparin-coated extracorporeal circuits with reduced systemic anticoagulation in routine coronary artery bypass operations
    Ovrum, E
    Tangen, G
    Oystese, R
    Ringdal, MAL
    Istad, R
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (02): : 324 - 330
  • [37] BLOOD DAMAGE DURING EXTRACORPOREAL-CIRCULATION WITH MEMBRANE-OXYGENATOR
    MORIMOTO, T
    OHI, T
    SAKAI, T
    YADA, I
    KUSAGAWA, M
    ARTIFICIAL ORGANS, 1981, 5 (03) : 326 - 326
  • [38] Heparin-coated versus uncoated extracorporeal circuit in patients undergoing coronary artery bypass graft surgery
    Oliver, WC
    Nuttall, GA
    Ereth, MH
    Santrach, PJ
    Buda, DA
    Schaff, HV
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (02) : 165 - 170
  • [39] EXTRACORPOREAL-CIRCULATION WITHOUT AN OXYGENATOR IN CORONARY-BYPASS GRAFTING
    BERGLIN, E
    SANDIN, O
    WINSTEDT, P
    WILLIAMOLSSON, G
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1986, 92 (02): : 306 - 308
  • [40] Biocompatibility of heparin-coated cardiopulmonary bypass circuits in coronary patients with left ventricular dysfunction is superior to PMEA-coated circuits
    Kutay, Veysel
    Noyan, Tevfik
    Ozcan, Sedat
    Melek, Yasin
    Ekim, Hasan
    Yakut, Cevat
    JOURNAL OF CARDIAC SURGERY, 2006, 21 (06) : 572 - 577