BIOCOMPATIBILITY OF EXTRACORPOREAL-CIRCULATION - INVITRO COMPARISON OF HEPARIN-COATED AND UNCOATED OXYGENATOR CIRCUITS

被引:0
|
作者
VIDEM, V
MOLLNES, TE
GARRED, P
SVENNEVIG, JL
机构
[1] UNIV OSLO,NATL HOSP,INST IMMUNOL & RHEUMATOL,OSLO 3,NORWAY
[2] UNIV OSLO,ULLEVAL HOSP,DEPT SURG,OSLO 1,NORWAY
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Oxygenator/tubing sets coated with endpoint-attached heparin were compared to uncoated sets in a dynamic model of extracorporeal circulation. Biocompatibility was assessed by evaluations of complement activation and platelet loss. The median concentration of C3 activation products increased gradually from 12 AU/ml at baseline to 65 AU/ml after 120 minutes in the uncoated sets and from 12 AU/ml to 19 AU/ml after 120 minutes in the coated sets (p < 0.002). The median concentration of the terminal complement complex in the uncoated sets increased gradually from 3.1 AU/ml at baseline to 18.2 AU/ml after 120 minutes. In the coated sets the terminal complement complex reached a peak of 12.0 AU/ml at 15 minutes and returned to baseline values at 60 minutes. Median platelet loss at 120 minutes was 166 X 10(9) in the uncoated and 21 X 10(9) in the coated sets (p < 0.01). Heparin coating thus improved biocompatibility by reducing both complement activation and platelet loss.
引用
收藏
页码:654 / 660
页数:7
相关论文
共 50 条
  • [1] COMPLEMENT ACTIVATION DURING EXTRACORPOREAL-CIRCULATION - IN-VITRO COMPARISON OF DURAFLO-II HEPARIN-COATED AND UNCOATED OXYGENATOR CIRCUITS
    SVENNEVIG, JL
    GEIRAN, OR
    KARLSEN, H
    PEDERSEN, T
    MOLLNES, TE
    KONGSGARD, U
    FROYSAKER, T
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 106 (03): : 466 - 472
  • [2] Biocompatibility in heparin-coated extracorporeal circuits
    Hsu, Li-Chien
    PERFUSION-UK, 1996, 11 (03): : 256 - 263
  • [3] HEPARIN-COATED VERSUS NON-COATED SURFACES FOR EXTRACORPOREAL-CIRCULATION
    MOTTAGHY, K
    OEDEKOVEN, B
    POPPEL, K
    KOVACS, B
    KIRSCHFINK, M
    BRUCHMULLER, K
    KASHEFI, A
    GEISEN, C
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (11): : 721 - 728
  • [4] Biomaterial-dependent blood activation during simulated extracorporeal circulation: a study of heparin-coated and uncoated circuits
    Borowiec, JW
    Venge, P
    Henze, A
    Nilsson, B
    Stiernstrom, H
    THORACIC AND CARDIOVASCULAR SURGEON, 1997, 45 (06): : 295 - 301
  • [5] Biocompatibility of heparin-coated extracorporeal bypass circuits: New heparin bonded Bioline system
    Tayama, E
    Hayashida, N
    Akasu, K
    Kosuga, T
    Fukunaga, S
    Akashi, H
    Kawara, T
    Aoyagi, S
    ARTIFICIAL ORGANS, 2000, 24 (08) : 618 - 623
  • [6] Issues of biocompatibility: Heparin-coated extracorporeal circuit
    Hsu, LC
    INTERNATIONAL ANESTHESIOLOGY CLINICS, 1996, 34 (02) : 109 - 122
  • [7] Biocompatibility of heparin-coated extracorporeal bypass circuits: A randomized, masked clinical trial
    Muehrcke, DD
    McCarthy, PM
    KottkeMarchant, K
    Harasaki, H
    PierreYared, J
    Borsh, JA
    Ogella, DA
    Cosgrove, DM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (02): : 472 - 483
  • [8] BIOCOMPATIBILITY OF HEPARIN-COATED CIRCUITS USED IN CARDIOPULMONARY BYPASS
    PEKNA, M
    BOROWIEC, J
    FAGERHOL, MK
    VENGE, P
    THELIN, S
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 28 (01): : 5 - 11
  • [9] BIOCOMPATIBILITY OF HEPARIN-COATED MEMBRANE-OXYGENATOR DURING CARDIOPULMONARY BYPASS
    HATORI, N
    YOSHIZU, H
    HAGA, Y
    KUSAMA, Y
    TAKESHIMA, S
    SEGAWA, D
    TANAKA, S
    ARTIFICIAL ORGANS, 1994, 18 (12) : 904 - 910
  • [10] Biocompatibility of heparin-coated circuits in pediatric cardiopulmonary bypass
    Kagisaki, K
    Masai, T
    Kadoba, K
    Sawa, Y
    Nomura, F
    Fukushima, N
    Ichikawa, H
    Ohata, T
    Suzuki, K
    Taketani, S
    Matsuda, H
    ARTIFICIAL ORGANS, 1997, 21 (07) : 836 - 840