PLANAR DETECTORS OF HIGH-PURITY GERMANIUM

被引:0
|
作者
GORNOV, MG [1 ]
GUROV, YB [1 ]
OSIPENKO, BP [1 ]
PODKOPAEV, OI [1 ]
SOLDATOV, AM [1 ]
JURKOWSKI, J [1 ]
机构
[1] KRASNOYARSK NONFERROUS MET PLANT,KRASNOYARSK,USSR
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The parameters of planar detectors produced from high-purity Ge are presented. The use of multilayer spectrometers based on these detector for nuclear-physics experiments is discussed. It is shown that the spectrometric characteristics of these detectors - including those of large area - have nearly the maximum possible values.
引用
收藏
页码:802 / 805
页数:4
相关论文
共 50 条
  • [21] NEUTRON DAMAGE AND ANNEALING IN HIGH-PURITY GERMANIUM RADIATION DETECTORS
    LLACER, J
    KRANER, HW
    NUCLEAR INSTRUMENTS & METHODS, 1972, 98 (03): : 467 - &
  • [22] A study of fast neutron interactions in high-purity germanium detectors
    Ljungvall, J
    Nyberg, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (03): : 553 - 573
  • [23] N-TYPE HIGH-PURITY GERMANIUM COAXIAL DETECTORS
    RAUDORF, TW
    TRAMMELL, RC
    DARKEN, LS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) : 297 - 302
  • [24] NUCLEAR-RADIATION DETECTORS BASE ON HIGH-PURITY GERMANIUM
    AVERYANO.VP
    GINZBURG, MI
    STROKAN, NB
    SUBASHIE.VP
    TISNEK, NI
    ATOMNAYA ENERGIYA, 1973, 34 (06): : 483 - 485
  • [25] Characterization of high-purity germanium detectors with amorphous germanium contacts in cryogenic liquids
    R. Panth
    J. Liu
    I. Abt
    X. Liu
    O. Schulz
    W.-Z. Wei
    H. Mei
    D.-M. Mei
    G.-J. Wang
    The European Physical Journal C, 2020, 80
  • [26] RESPONSE OF HIGH-PURITY GERMANIUM DETECTORS TO CHARGED-PARTICLES
    BACHER, AD
    SLOAN, WT
    KOVAR, DG
    PEHL, RH
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 529 - 529
  • [27] PHOTOMASK TECHNIQUE FOR FABRICATING HIGH-PURITY GERMANIUM STRIP DETECTORS
    GUTKNECHT, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01): : 13 - 18
  • [28] EFFECT OF DISLOCATION OF ENERGY RESOLUTION OF HIGH-PURITY GERMANIUM DETECTORS
    GLASOW, PA
    HALLER, EE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (01) : 92 - 96
  • [29] THE USE OF PLANAR HIGH-PURITY GERMANIUM DETECTORS FOR THE INVIVO MEASUREMENT OF LOW-ENERGY PHOTON EMITTERS
    PALMER, HE
    RIEKSTS, GA
    HEALTH PHYSICS, 1983, 45 (01): : 232 - 232
  • [30] TEMPORAL INSTABILITIES ASSOCIATED WITH A PLANAR HIGH-PURITY GERMANIUM DETECTOR
    PUGH, ND
    OWEN, GM
    EVANS, WD
    PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (05): : 625 - 632