A Case of Acute Angle Closure Caused by Dislocation of Accommodative Intraocular Lens

被引:0
|
作者
Hwang, Hyun Ji [1 ]
Hwang, Young Hoon [1 ]
Lee, Jung Jin [2 ]
Kim, Byoung Yeop [1 ]
机构
[1] Konyang Univ, Kims Eye Hosp, Myung Gok Eye Res Inst, Dept Ophthalmol,Coll Med, Seoul, South Korea
[2] Seoul Ire Eye Clin, Seoul, South Korea
来源
关键词
Accommodative intraocular lens; Angle closure; Cataract; Glaucoma; WIOL-CF (R);
D O I
10.3341/jkos.2016.57.9.1493
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report a case of acute angle closure after cataract surgery using an accommodative intraocular lens (IOL), WIOL-CF (R) (GELMED, Praha, Czech). Case summary: A 46-year-old male patient underwent phacoemulsification and implantation of WIOL-CF (R) into the capsular bag. Seven months after the surgery, a sudden increase in intraocular pressure (IOP) associated with angle closure was observed. Ultrabiomicroscopy revealed a dislocated WIOL-CF (R) that was pushing the peripheral iris anteriorly. Despite the use of IOP-lowering medication and peripheral laser iridotomy, IOP was not controlled. After the use of cycloplegics, the angle was widened and IOP decreased; however, after nine days, the WIOL-CF (R) was completely dislocated into the anterior chamber and so was removed. Conclusions: When performing cataract surgery using WIOL-CF (R), a possibility of dislocation of IOL and subsequent angle closure should be considered.
引用
收藏
页码:1493 / 1497
页数:5
相关论文
共 50 条
  • [21] Phacoemulsification and intraocular lens implantation for acute angle closure not treated or previously treated by laser iridotomy
    Imaizumi, M
    Takaki, Y
    Yamashita, H
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (01): : 85 - 90
  • [22] Early versus Delayed Phacoemulsification and Intraocular Lens Implantation for Acute Primary Angle-Closure
    Lin, Yun-Hsuan
    Wu, Cheng-Hsiu
    Huang, Shih-Ming
    Hsieh, Chen
    Chen, Henry Shen-Lih
    Ku, Wan-Chen
    Sun, Ming-Hui
    Su, Wei-Wen
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [24] Intraocular Lens Dislocation
    Sacks, Chana A.
    NEW ENGLAND JOURNAL OF MEDICINE, 2021, 384 (21): : 2053 - 2053
  • [25] Intraocular lens dislocation
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (07): : 973 - 974
  • [26] Response to regarding the case image article entitled "A case of angle-closure glaucoma caused by spontaneous lens dislocation" by Kondo et al.
    Kondo, Keisuke
    Isono, Hiroki
    CLINICAL CASE REPORTS, 2024, 12 (05):
  • [27] Secondary Angle Closure Caused by Anterior Displacement of Capsular Tension Ring and Intraocular Lens Due to Aqueous Misdirection
    Goto, Kensuke
    Tomita, Ryo
    Hiraiwa, Jiro
    Kawabe, Mitsuki
    Nishiguchi, Koji M.
    Yuki, Kenya
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [28] Accommodative intraocular lens: A challenge for future development
    Assia, EI
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (04): : 458 - 460
  • [29] Technology needs for the development of the accommodative intraocular lens
    Nishi, Okihiro
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [30] Potential of the 1 CU accommodative intraocular lens
    Sauder, G
    Degenring, RF
    Kamppeter, B
    Hugger, P
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (10) : 1289 - 1292