Potential of the 1 CU accommodative intraocular lens

被引:19
|
作者
Sauder, G
Degenring, RF
Kamppeter, B
Hugger, P
机构
[1] Univ Heidelberg, Augenklin, Dept Ophthalmol, D-68167 Mannheim, Germany
[2] Univ Heidelberg, Hosp Eye, Fac Clin Med Mannheim, D-68167 Mannheim, Germany
关键词
D O I
10.1136/bjo.2005.068056
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To assess the accommodative power of a new foldable monofocal intraocular lens. Method: A prospective randomised non-masked clinical interventional study. The study included 40 patients attending the hospital for cataract surgery and who were randomly distributed into a study group receiving a new foldable monofocal intraocular lens with flexible haptics, and a control group receiving a standard foldable intraocular lens. Mean follow up period was 8.51 (SD 1.34) months ( range 4 11 months) Standard cataract surgery consisted of clear cornea incision, capsulorrhexis, phacoemulsification, and intraocular lens implantation, with topical anaesthesia. The main outcome measures were preoperative and postoperative visual acuity for near and distance; range of accommodation; change in anterior chamber depth. Results: In the study group compared with the control group, range of accommodation was significantly ( p = 0.01) higher (1.01 ( SD 0.4) dioptres versus 0.50 (0.11) dioptres) and change in anterior chamber depth was significantly more pronounced (0.82 ( 0.30) versus 0.40 (0.32), p = 0.01). Both groups did not vary significantly in best corrected vision (0.94 ( 0.12) versus 0.93 (0.18); p = 0.74). Conclusion: During a mean follow up period of 8 months after implantation, the new foldable monofocal intraocular lens with flexible haptics showed an accommodative power of about 1 dioptre, which was significantly higher than the accommodative power of a conventional monofocal flexible intraocular lens. The difference in the accommodative power between the two intraocular lenses was paralleled by a difference in the change of the anterior chamber depth.
引用
收藏
页码:1289 / 1292
页数:4
相关论文
共 50 条
  • [1] Objective accommodative amplitude and dynamics with the 1CU accommodative intraocular lens
    Wolffsohn, JS
    Hunt, OA
    Naroo, S
    Gilmartin, B
    Shah, S
    Cunliffe, IA
    Benson, MT
    Mantry, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) : 1230 - 1235
  • [2] Two years experience with the new accommodative 1 CU intraocular lens
    Küchle, M
    Nguyen, NX
    Langenbucher, A
    Gusek-Schneider, GC
    Seitz, B
    OPHTHALMOLOGE, 2002, 99 (11): : 820 - 824
  • [3] An accommodative intraocular lens
    Packer, Mark
    EXPERT REVIEW OF OPHTHALMOLOGY, 2013, 8 (04) : 317 - 319
  • [4] Accommodative intraocular lens concepts
    Eppig, Timo
    ACTA OPHTHALMOLOGICA, 2019, 97
  • [5] Accommodative intraocular lens tilting
    Cazal, J
    Lavin-Dapena, C
    Marín, J
    Vergés, C
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 341 - 344
  • [6] Analysis of Accommodative Performance of a New Accommodative Intraocular Lens
    Alio, Jorge L.
    Simonov, Aleksey N.
    Romero, Daniel
    Angelov, Alexander
    Angelov, Yavor
    van Lawick, Willem
    Rombach, Michiel C.
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (02) : 78 - +
  • [7] Comparison of 6-month results of implantation of the 1CU accommodative intraocular lens with conventional intraocular lenses
    Küchle, M
    Seitz, B
    Langenbucher, A
    Gusek-Schneider, GC
    Martus, P
    Nguyen, NX
    OPHTHALMOLOGY, 2004, 111 (02) : 318 - 324
  • [8] The AkkoLens Lumina accommodative intraocular lens
    Rombach, M.
    ACTA OPHTHALMOLOGICA, 2014, 92
  • [9] In vitro test of an accommodative intraocular lens
    Shen, J
    O'Day, DM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U47 - U47
  • [10] The AkkoLens Lumina accommodative intraocular lens
    Rombach, Michiel
    ACTA OPHTHALMOLOGICA, 2019, 97