Potential of the 1 CU accommodative intraocular lens

被引:19
|
作者
Sauder, G
Degenring, RF
Kamppeter, B
Hugger, P
机构
[1] Univ Heidelberg, Augenklin, Dept Ophthalmol, D-68167 Mannheim, Germany
[2] Univ Heidelberg, Hosp Eye, Fac Clin Med Mannheim, D-68167 Mannheim, Germany
关键词
D O I
10.1136/bjo.2005.068056
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To assess the accommodative power of a new foldable monofocal intraocular lens. Method: A prospective randomised non-masked clinical interventional study. The study included 40 patients attending the hospital for cataract surgery and who were randomly distributed into a study group receiving a new foldable monofocal intraocular lens with flexible haptics, and a control group receiving a standard foldable intraocular lens. Mean follow up period was 8.51 (SD 1.34) months ( range 4 11 months) Standard cataract surgery consisted of clear cornea incision, capsulorrhexis, phacoemulsification, and intraocular lens implantation, with topical anaesthesia. The main outcome measures were preoperative and postoperative visual acuity for near and distance; range of accommodation; change in anterior chamber depth. Results: In the study group compared with the control group, range of accommodation was significantly ( p = 0.01) higher (1.01 ( SD 0.4) dioptres versus 0.50 (0.11) dioptres) and change in anterior chamber depth was significantly more pronounced (0.82 ( 0.30) versus 0.40 (0.32), p = 0.01). Both groups did not vary significantly in best corrected vision (0.94 ( 0.12) versus 0.93 (0.18); p = 0.74). Conclusion: During a mean follow up period of 8 months after implantation, the new foldable monofocal intraocular lens with flexible haptics showed an accommodative power of about 1 dioptre, which was significantly higher than the accommodative power of a conventional monofocal flexible intraocular lens. The difference in the accommodative power between the two intraocular lenses was paralleled by a difference in the change of the anterior chamber depth.
引用
收藏
页码:1289 / 1292
页数:4
相关论文
共 50 条
  • [41] A Randomized Intraindividual Comparison of the Accommodative Performance of the Bag-in-the-Lens Intraocular Lens in Presbyopic Eyes
    Cleary, Georgia
    Spalton, David J.
    Gala, Kavita B.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (05) : 619 - 627
  • [42] Optimized multielement accommodative intraocular lens with a four-freeform-surface Alvarez lens and a separate aspheric lens
    Wang, Liang-Yu
    Li, Bai-Cheng
    Sheng, Bin
    Xu, Bang-Lian
    Huang, Yuan-Shen
    Ni, Zheng-Ji
    Zhang, Da-Wei
    APPLIED OPTICS, 2019, 58 (27) : 7609 - 7614
  • [43] Vision, subjective accommodation and lens mobility after Tetra Flex accommodative intraocular lens implantation
    Dong Zhe
    Wang Ning-li
    Li Jun-hong
    CHINESE MEDICAL JOURNAL, 2010, 123 (16) : 2221 - 2224
  • [44] Clinical study of the 1CU accommodating intraocular lens
    Mastropasqua, L
    Toto, L
    Nubile, M
    Falconio, G
    Ballone, E
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1307 - 1312
  • [45] Visual and accommodative outcomes 1 year after implantation of an accommodating intraocular lens based on a new concept
    Alio, Jorge L.
    Ben-nun, Joshua
    Rodriguez-Prats, Jose L.
    Plaza, Ana B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (10): : 1671 - 1678
  • [46] Cardinal points and image-object magnification with an accommodative lens implant (1 CU)
    Langenbucher, A
    Huber, S
    Nguyen, NX
    Seitz, B
    Küchle, M
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (01) : 61 - 70
  • [47] ACCOMMODATIVE INTRAOCULAR-LENS WITH SPRING ACTION .1. DESIGN AND PLACEMENT IN AN EXCISED ANIMAL EYE
    HARA, T
    HARA, T
    YASUDA, A
    YAMADA, Y
    OPHTHALMIC SURGERY AND LASERS, 1990, 21 (02): : 128 - 133
  • [48] Laserinterferometric Measurements of Accommodative Changes in the Position of an Optic-shift Intraocular Lens
    Uthoff, Detlef
    Holland, Detlef
    Hepper, Daniel
    Gulati, Amit
    Koch, Lioba
    Haigis, Wolfgang
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (05) : 416 - 420
  • [49] First results of implantation of a new, potentially accommodative posterior chamber intraocular lens
    Küchle, M
    Langenbucher, A
    Gusek-Schneider, GC
    Seitz, B
    Hanna, KD
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (09) : 603 - 608
  • [50] Subjective and objective performance of the Lenstec KH-3500 "accommodative'' intraocular lens
    Wolffsohn, JS
    Naroo, SA
    Motwani, NK
    Shah, S
    Hunt, OA
    Mantry, S
    Sira, M
    Cunliffe, IA
    Benson, MT
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (06) : 693 - 696