Potential of the 1 CU accommodative intraocular lens

被引:19
|
作者
Sauder, G
Degenring, RF
Kamppeter, B
Hugger, P
机构
[1] Univ Heidelberg, Augenklin, Dept Ophthalmol, D-68167 Mannheim, Germany
[2] Univ Heidelberg, Hosp Eye, Fac Clin Med Mannheim, D-68167 Mannheim, Germany
关键词
D O I
10.1136/bjo.2005.068056
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To assess the accommodative power of a new foldable monofocal intraocular lens. Method: A prospective randomised non-masked clinical interventional study. The study included 40 patients attending the hospital for cataract surgery and who were randomly distributed into a study group receiving a new foldable monofocal intraocular lens with flexible haptics, and a control group receiving a standard foldable intraocular lens. Mean follow up period was 8.51 (SD 1.34) months ( range 4 11 months) Standard cataract surgery consisted of clear cornea incision, capsulorrhexis, phacoemulsification, and intraocular lens implantation, with topical anaesthesia. The main outcome measures were preoperative and postoperative visual acuity for near and distance; range of accommodation; change in anterior chamber depth. Results: In the study group compared with the control group, range of accommodation was significantly ( p = 0.01) higher (1.01 ( SD 0.4) dioptres versus 0.50 (0.11) dioptres) and change in anterior chamber depth was significantly more pronounced (0.82 ( 0.30) versus 0.40 (0.32), p = 0.01). Both groups did not vary significantly in best corrected vision (0.94 ( 0.12) versus 0.93 (0.18); p = 0.74). Conclusion: During a mean follow up period of 8 months after implantation, the new foldable monofocal intraocular lens with flexible haptics showed an accommodative power of about 1 dioptre, which was significantly higher than the accommodative power of a conventional monofocal flexible intraocular lens. The difference in the accommodative power between the two intraocular lenses was paralleled by a difference in the change of the anterior chamber depth.
引用
收藏
页码:1289 / 1292
页数:4
相关论文
共 50 条
  • [21] Safety, biocompatibility, and potential functionality of a new accommodative intraocular lens: An experimental study in rabitts
    Olcina, Luis Ignacio
    Bueno, Ivan Fernandez
    Iglesias, Cristina Andres
    Iglesias, Kevin Puertas
    Martinez, Itziar Fernandez
    Martin, Ricardo Usategui
    Lopez, Miguel Jose Maldonado
    ACTA OPHTHALMOLOGICA, 2024, 102
  • [22] Safety, biocompatibility, and potential functionality of a new accommodative intraocular lens: An experimental study in rabbits
    Fernandez-Bueno, Ivan
    Olcina, Luis Ignacio
    Andres-Iglesias, Cristina
    Puertas-Neyra, Kevin
    Fernandez-Martinez, Itziar
    Usategui-Martin, Ricardo
    Maldonado-Lopez, Miguel Jose
    HELIYON, 2023, 9 (09)
  • [23] Longterm results of 1 CU® accommodative intraocular lens implantation:: 2-year follow-up study
    Mastropasqua, Leonardo
    Toto, Lisa
    Falconio, Gennaro
    Nubile, Mario
    Carpineto, Paolo
    Ciancaglini, Marco
    Di Nicola, Marta
    Ballone, Enzo
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (04): : 409 - 414
  • [24] Outcomes After Accommodative Bioanalogic Intraocular Lens Implantation
    Pallikaris, Ioannis G.
    Portaliou, Dimitra M.
    Kymionis, George D.
    Panagopoulou, Sophia I.
    Kounis, George A.
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (06) : 402 - +
  • [25] Implantation of a new accommodative posterior chamber intraocular lens
    Küchle, M
    Nguyen, NX
    Langenbucher, A
    Gusek-Schneider, GC
    Seitz, B
    Hanna, KD
    JOURNAL OF REFRACTIVE SURGERY, 2002, 18 (03) : 208 - 216
  • [26] Evaluation of an accommodative Intraocular lens in human and rabbit eyes
    Pandey, SK
    Werner, L
    Apple, DJ
    Izak, AM
    Trivedi, RH
    McLeod, SD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U88 - U88
  • [27] Changes of the accommodative amplitude and the anterior chamber depth after implantation of an accommodative intraocular lens
    Schneider, H
    Stachs, O
    Göbel, K
    Guthoff, R
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (03) : 322 - 329
  • [28] Changes of the accommodative amplitude and the anterior chamber depth after implantation of an accommodative intraocular lens
    Hanka Schneider
    Oliver Stachs
    Katja Göbel
    Rudolf Guthoff
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2006, 244 : 322 - 329
  • [29] Zwei Jahre Erfahrung mit der akkommodativen Hinterkammerlinse 1 CUTwo years experience with the new accommodative 1 CU intraocular lens
    M. Küchle
    N. X. Nguyen
    A. Langenbucher
    G. C. Gusek-Schneider
    B. Seitz
    Der Ophthalmologe, 2002, 99 : 820 - 824
  • [30] Validity of anterior chamber depth measurements for the evaluation of accommodation after implantation of an accommodative Humanoptics 1CU intraocular lens
    Auffarth, GU
    Martin, M
    Fuchs, HA
    Rabsilber, TM
    Becker, KA
    Schmack, I
    OPHTHALMOLOGE, 2002, 99 (11): : 815 - 819