Clear Lens Surgery and Tecnis Multifocal Intraocular Lens Implantation in Presbyopic Hyperopic Eyes

被引:0
|
作者
Akyol, Sibel [1 ]
Kubaloglu, Anil [1 ]
Koytak, Arif Ibrahim [1 ]
Kurnaz, Ekrem [1 ]
Ozerturk, Yusuf [1 ]
机构
[1] Dr Lutfi Kurdar Kartal Egitim Arafltsrma Hastan, Istanbul, Turkey
关键词
Presbyopia; multifocal; diffractive;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate refractive and visual results of clear lens surgery and Tecnis multifocal intraocular lens implantation in presbyopic farsighted eyes and to assess patient satisfaction. Materials-Methods: Thirty eyes of fifteen presbyopic farsighted patients who had refractive lens surgery with Tecnis ZM900 multifocal lens implantation for the treatment of both near and far vision are included in the study. Uncorrected and best-corrected visual acuities in near and far, refractive errors and contrast sensitivities of the eyes and patient satisfaction criteria are recorded in the first and sixth months postoperatively. Results: Mean uncorrected far visual acuity is measured 0.68 +/- 0.19 in the first month postoperatively and 0.88 +/- 0.12 in the sixth month. Best corrected far visual acuity was found 0.8 or above in all eyes both in the first and sixth months following the surgery. Uncorrected near visual acuities in the first month were measured Jaeger 2 (J2) or better in 93 percent of the eyes, while in the sixth month 94 percent of the eyes had an uncorrected near visual acuities of J1. Postoperative mean spherical equivalents were measured +0.60 +/- 0.50 diopters (D) in the first month and -0.03 +/- 0.48D in the sixth month. Photopic contrast sensitivity in all spatial frequencies improved significantly in the sixth month compared to the first month after the operation (p<0,05). In the first month 34 percent of the patients complained of glare and 40 percent complained of halos, while in the sixth month 20 percent complained of glare and 20 percent of halos. Except one, all patients were satisfied with the visual results. Conclusions: Clear lens surgery with Tecnis multifocal intraocular lens implantation in presbyopic farsighted eyes provided satisfactory results in near and far vision independent of glasses. Although majority of patients had night vision problems, overall patient satisfaction was high.
引用
收藏
页码:103 / 109
页数:7
相关论文
共 50 条
  • [41] Bilateral Mutifocal Intraocular Lens Implantation on an Postoperative Hyperopic Patient
    Tunc, Zeki
    Ercalik, Yesim
    Sencan, Sadik
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2009, 39 (02): : 133 - 136
  • [42] Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report
    Hida, Wilson Takashi
    Motta, Antonio Francisco
    Nakano, Celso Takashi
    Tzelikis, Patrick F.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (06) : 427 - 429
  • [43] Visual performance, safety, and patient satisfaction after binocular clear lens extraction and trifocal intraocular lens implantation in Chinese presbyopic patients
    Chen, Lulu
    Sun, Lu
    Tang, Yongxiang
    Sui, Wenda
    Bian, Ailing
    Zhang, Xia
    Wang, Zaowen
    Zhong, Yong
    Zhang, Shunhua
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [44] Presbyopic lens exchange (PRELEX) cataract surgery outcomes with implantation of a rotationally asymmetric refractive multifocal intraocular lens: femtosecond laser-assisted versus manual phacoemulsification
    Peter Žiak
    Juraj Halička
    Peter Mojžiš
    Karolína Kapitánová
    Javorka Michal
    David P. Piñero
    International Ophthalmology, 2019, 39 : 2875 - 2882
  • [45] Cataract surgery and intraocular lens implantation in children, and intraocular lens implantation in children - Reply
    Rosenbaum, AL
    Masket, S
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 121 (02) : 225 - 226
  • [46] Effect of Distance Refractive Error on Intermediate Vision with the Tecnis® Multifocal Intraocular Lens
    Jegatheeswaran, Jehanya
    Kwok, Lawrence
    Yan, David B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [47] Clear lens extraction and intraocular lens implantation in Marfan's syndrome
    Siganos, DS
    Siganos, CS
    Popescu, CN
    Margaritis, VN
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (05): : 781 - 784
  • [48] Multifocal intraocular lens (MIOL) surgery in young non-presbyopic ametropes. Reasonable and safe?
    Frings, A.
    Steinberg, J.
    Linke, S. J.
    Druchkiv, V.
    Katz, T.
    OPHTHALMOLOGE, 2017, 114 (08): : 722 - 727
  • [49] Visual quality after diffractive intraocular lens implantation in eyes with previous hyperopic laser in situ keratomileusis
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Baamonde, Begona
    Madrid-Costa, David
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1090 - 1096
  • [50] A New Biconcave Contact Lens for Vitrectomy in Eyes With Intraocular Lens Implantation
    Hitani, Koichiro
    Futamura, Hideyuki
    Shiba, Tomoaki
    Hori, Yuichi
    Saishin, Yoshitsugu
    Maeno, Takatoshi
    OPHTHALMIC SURGERY LASERS & IMAGING, 2011, 42 (06) : 523 - 525