Purpose: To evaluate refractive and visual results of clear lens surgery and Tecnis multifocal intraocular lens implantation in presbyopic farsighted eyes and to assess patient satisfaction. Materials-Methods: Thirty eyes of fifteen presbyopic farsighted patients who had refractive lens surgery with Tecnis ZM900 multifocal lens implantation for the treatment of both near and far vision are included in the study. Uncorrected and best-corrected visual acuities in near and far, refractive errors and contrast sensitivities of the eyes and patient satisfaction criteria are recorded in the first and sixth months postoperatively. Results: Mean uncorrected far visual acuity is measured 0.68 +/- 0.19 in the first month postoperatively and 0.88 +/- 0.12 in the sixth month. Best corrected far visual acuity was found 0.8 or above in all eyes both in the first and sixth months following the surgery. Uncorrected near visual acuities in the first month were measured Jaeger 2 (J2) or better in 93 percent of the eyes, while in the sixth month 94 percent of the eyes had an uncorrected near visual acuities of J1. Postoperative mean spherical equivalents were measured +0.60 +/- 0.50 diopters (D) in the first month and -0.03 +/- 0.48D in the sixth month. Photopic contrast sensitivity in all spatial frequencies improved significantly in the sixth month compared to the first month after the operation (p<0,05). In the first month 34 percent of the patients complained of glare and 40 percent complained of halos, while in the sixth month 20 percent complained of glare and 20 percent of halos. Except one, all patients were satisfied with the visual results. Conclusions: Clear lens surgery with Tecnis multifocal intraocular lens implantation in presbyopic farsighted eyes provided satisfactory results in near and far vision independent of glasses. Although majority of patients had night vision problems, overall patient satisfaction was high.
引用
收藏
页码:103 / 109
页数:7
相关论文
共 50 条
  • [21] Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens
    Lubinski, Wojciech
    Kazmierczak, Beata
    Gronkowska-Serafin, Jolanta
    Podbordczynska-Jodko, Karolina
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [22] Late intraocular lens exchange in dissatisfied patients with multifocal intraocular lens implantation
    Kuo, Yu-Wei
    Hou, Yu-Chih
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2022, 12 (01) : 109 - 112
  • [23] Primary piggyback implantation using the Tecnis ZM900 multifocal intraocular lens - Case series
    Akaishi, Leonardo
    Tzelikis, Patrick F.
    Gondirn, Joyce
    Vaz, Rodrigo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12): : 2067 - 2071
  • [24] Usefulness of Implantation of Diffractive Multifocal Intraocular Lens in Eyes with Long Axial Lengths
    Ogawa, Tomoichiro
    Shiba, Takuya
    Tsuneoka, Hiroshi
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [25] Diffractive multifocal intraocular lens implantation in eyes with a small-diameter pupil
    Masayuki Ouchi
    Takuya Shiba
    Scientific Reports, 8
  • [26] Diffractive multifocal intraocular lens implantation in eyes with a small-diameter pupil
    Ouchi, Masayuki
    Shiba, Takuya
    SCIENTIFIC REPORTS, 2018, 8
  • [27] Visual Outcomes and Patient Satisfaction After Presbyopic Lens Exchange With a Diffractive Multifocal Intraocular Lens
    Chang, John S. M.
    Ng, Jack C. M.
    Lau, Silvania Y. F.
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (07) : 468 - +
  • [28] Evolution of visual performance in 70 eyes implanted with the Tecnis((R)) ZMB00 multifocal intraocular lens
    Palomino Bautista, Carlos
    Carmona Gonzalez, David
    Castillo Gomez, Alfredo
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 403 - 407
  • [29] Effect of presbyopic correction lens on humphrey visual field testing in patients with multifocal intraocular lens
    Kitnarong, Naris
    Petchyim, Sakaorat
    Jampathong, Pennapar
    Treesit, Isaraporn
    Limmahachai, Arnan
    Aurboonsong, Tanakorn
    MEDICINE, 2023, 102 (41) : E35544
  • [30] Ultrasound biomicroscopy of the Artisan phakic intraocular lens in hyperopic eyes
    Pop, M
    Payette, Y
    Mansour, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (10): : 1799 - 1803