Experimental Evaluation of Vibration Response of External Post-Tensioned Tendons with Corrosion

被引:0
|
作者
Jun Ki Lee
Jun Won Kang
机构
[1] Samsung C&T Corporation,Engineering Team
[2] Hongik University,Dept. of Civil Engineering
来源
关键词
bridges; tendon; corrosion; frequency responses; vibration; damage;
D O I
暂无
中图分类号
学科分类号
摘要
This study investigates the vibration responses of external post-tensioned (PT) tendons based on experimental data. The vibration signals measured from four large-scale external post-tensioned tendon specimens subjected to localized corrosion until severe level of damage were accumulated. A series of impact tests was conducted to measure lateral vibration signals and the variation in the tension was continuously monitored using a load cell. The acquired vibration signals were evaluated using an axially-tensioned beam model in which the properties were varied to reflect the loss of tension and the reduction in the bending stiffness caused by corrosion damage. A comparison between the experimental data and the analytical results indicates that the natural frequencies were shifted as the residual tension decreased but were influenced by corresponding grout damage in a limited range. As a result, the frequency response was not appreciably affected by the damage level and the tension remained as the primary structural parameter of the external PT tendon with damage.
引用
收藏
页码:2561 / 2572
页数:11
相关论文
共 50 条
  • [21] Analytical and experimental response of timber joists strengthened with external underslung post-tensioned system
    Orfeo, Benedetta
    Trujillo, Fernando
    Corral, Maria del Mar
    Todisco, Leonardo
    ENGINEERING STRUCTURES, 2024, 308
  • [22] An experimental study on the flexural behavior of post-tensioned concrete beams with CFRP tendons
    Jung, Woo-Tai
    Park, Jong-Sup
    Park, Young-Hwan
    Applied Mechanics and Materials, 2013, 351-352 : 717 - 721
  • [23] Experimental study on post-tensioned and unbonded concrete beams reinforced with CFRP tendons
    Zhu, J
    Dai, SB
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 1119 - 1124
  • [24] Non-destructive testing methods to identify voids in external post-tensioned tendons
    Im, Seok Been
    Hurlebaus, Stefan
    KSCE JOURNAL OF CIVIL ENGINEERING, 2012, 16 (03) : 388 - 397
  • [25] An Experimental Study on the Flexural Behavior of Post-tensioned Concrete Beams with CFRP Tendons
    Jung, Woo-tai
    Park, Jong-sup
    Park, Young-hwan
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 717 - 721
  • [26] Non-destructive testing methods to identify voids in external post-tensioned tendons
    Seok Been Im
    Stefan Hurlebaus
    KSCE Journal of Civil Engineering, 2012, 16 : 388 - 397
  • [27] Failure Forecasting of Corroding Bridge Post-Tensioned Tendons
    Hartt, William H.
    CORROSION, 2022, 78 (05) : 457 - 462
  • [28] Residual Tensile Capacity of Grouted Post-Tensioned Tendons
    Wood, Sharon L.
    McKinstry, Christopher A.
    Lee, Jun Ki
    ACI STRUCTURAL JOURNAL, 2013, 110 (06) : 1099 - 1107
  • [29] Post-tensioned slab bridge with banded transverse tendons
    Roschke, PN
    Pruski, KR
    ACI STRUCTURAL JOURNAL, 2000, 97 (01) : 3 - 10
  • [30] Corrosion in bonded post-tensioned structures
    Goodwin, F
    MATERIALS PERFORMANCE, 2002, 41 (10) : 38 - 43