Experimental Evaluation of Vibration Response of External Post-Tensioned Tendons with Corrosion

被引:0
|
作者
Jun Ki Lee
Jun Won Kang
机构
[1] Samsung C&T Corporation,Engineering Team
[2] Hongik University,Dept. of Civil Engineering
来源
关键词
bridges; tendon; corrosion; frequency responses; vibration; damage;
D O I
暂无
中图分类号
学科分类号
摘要
This study investigates the vibration responses of external post-tensioned (PT) tendons based on experimental data. The vibration signals measured from four large-scale external post-tensioned tendon specimens subjected to localized corrosion until severe level of damage were accumulated. A series of impact tests was conducted to measure lateral vibration signals and the variation in the tension was continuously monitored using a load cell. The acquired vibration signals were evaluated using an axially-tensioned beam model in which the properties were varied to reflect the loss of tension and the reduction in the bending stiffness caused by corrosion damage. A comparison between the experimental data and the analytical results indicates that the natural frequencies were shifted as the residual tension decreased but were influenced by corresponding grout damage in a limited range. As a result, the frequency response was not appreciably affected by the damage level and the tension remained as the primary structural parameter of the external PT tendon with damage.
引用
收藏
页码:2561 / 2572
页数:11
相关论文
共 50 条
  • [11] Evaluation and Mitigation of Post-Tensioned Steel Corrosion
    Whitmore, David
    Arnesen, Tore
    FORENSIC ENGINEERING 2018: FORGING FORENSIC FRONTIERS, 2018, : 879 - 892
  • [12] Post-tensioned tendon corrosion evaluation and mitigation
    Liao, H.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE EXTENSION, 2014, : 1966 - 1970
  • [13] DESIGN METHOD OF REINFORCED CONCRETE BEAMS WITH POST-TENSIONED EXTERNAL TENDONS.
    Zhang Xiaoyi
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 1985, 6 (03): : 44 - 57
  • [14] Experimental study of punching shear in post-tensioned slabs with unbonded tendons
    Choi, Seung-Ho
    Hwang, Jin-Ha
    Han, Sun-Jin
    Joo, Hyo-Eun
    Kim, Jae-Hyun
    Kim, Kang Su
    STRUCTURAL ENGINEERING AND MECHANICS, 2021, 79 (04) : 507 - 516
  • [15] Parametric Study of the External Strengthening of Composite Beams Using Post-Tensioned Tendons
    El-Zohairy, Ayman
    Salim, Hani
    STRUCTURES CONGRESS 2017: BRIDGES AND TRANSPORTATION STRUCTURES, 2017, : 58 - 67
  • [16] Friction loss of CFRP post-tensioned tendons
    Burke, B
    Nelson, J
    Dolan, C
    ADVANCED COMPOSITE MATERIALS IN BRIDGES AND STRUCTURES, 2000, : 249 - 257
  • [17] Determination of the repair grout volume to fill voids in external post-tensioned tendons
    Im, Seok Been
    Hurlebaus, Stefan
    STRUCTURAL ENGINEERING AND MECHANICS, 2012, 42 (01) : 25 - 38
  • [18] Indirect electrochemical impedance spectroscopy for corrosion detection in external post-tensioned tendons: 1. Proof of concept
    Alexander, Christopher L.
    Orazem, Mark E.
    CORROSION SCIENCE, 2020, 164
  • [19] Nondestructive evaluation of grout defects in internal tendons of post-tensioned girders
    Terzioglu, Tevfik
    Karthik, Madhu M.
    Hurlebaus, Stefan
    Hueste, Mary Beth D.
    Maack, Stefan
    Woestmann, Jens
    Wiggenhauser, Herbert
    Krause, Martin
    Miller, Patrick K.
    Olson, Larry D.
    NDT & E INTERNATIONAL, 2018, 99 : 23 - 35
  • [20] Cathodic Protection in Grouted Post-Tensioned Tendons
    不详
    MATERIALS PERFORMANCE, 2016, 55 (11) : 32 - +