Application of micro-computed X-ray tomography for improving the hole erosion test analysis on high plastic clay

被引:0
|
作者
Bahaeldeen Zaid
Florian Vollert
Jens Gibmeier
Lena Mengel
Oliver Stelzer
Achim Schneider
机构
[1] Federal Waterways Engineering and Research Institute (BAW),Geotechnical Department
[2] Karlsruhe Institute of Technology (KIT),Institute for Applied Materials (IAM
来源
Acta Geotechnica | 2023年 / 18卷
关键词
Computed X-ray tomography; Erosion parameters; High plastic clay; Hole erosion test;
D O I
暂无
中图分类号
学科分类号
摘要
The hole erosion test (HET) was developed to simulate piping erosion and to study the erosion parameters of cohesive soils. The erosion rate in the HET is evaluated by the enlargement of a pre-performed hole in the axis of the specimen with time. The hole diameter during the test is estimated using the pipe flow theory with an assumption that the friction factor varies linearly with time. To investigate this assumption, measurements of the hole diameter during the test are needed. So far, there have been no measurements of the hole diameter during the HET and the hole diameter is measured only at the end of the test after cutting the specimen. In this study, a novel approach to measure the hole diameter at different time steps during the HET using micro-computed X-ray tomography (µCT) is presented. Combining the HET and µCT data, the assumption regarding the friction factor was investigated. Moreover, a linear relation between the flow rate and the hole diameter was found in the range of the tested diameters. This relation was confirmed with HETs using non-erodible PVC specimens with different hole diameters. Accordingly, a new method to interpret the HET for high plastic clay was proposed, in which the hole diameter is calculated based on the flow rate, given that the initial and the final hole diameters are known. A comparison between the analysis of the HET using the proposed and the previous analysis methods is presented.
引用
收藏
页码:865 / 876
页数:11
相关论文
共 50 条
  • [31] X-ray micro-computed tomography (CT): an emerging opportunity in parasite imaging
    O'Sullivan, James D. B.
    Behnsen, Julia
    Starborg, Tobias
    MacDonald, Andrew S.
    Phythian-Adams, Alexander T.
    Else, Kathryn J.
    Cruickshank, Sheena M.
    Withers, Philip J.
    PARASITOLOGY, 2018, 145 (07) : 848 - 854
  • [32] X-ray micro-computed tomography system: Novel applications in bone imaging
    Latson, L
    Kuban, B
    Bryan, J
    Stredney, D
    Davros, W
    Midura, R
    Apte, S
    Powell, K
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 1058 - 1061
  • [33] The Effect of Experiment Variabies on Industrial X-ray Micro-computed Tomography Sensitivity
    Roth, D. J.
    Rauser, R. W.
    MATERIALS EVALUATION, 2015, 73 (12) : 1577 - 1584
  • [34] X-ray micro-computed tomography and tortuosity calculations of percolating pore networks
    Shanti, Noah O.
    Chan, Victor W. L.
    Stock, Stuart R.
    De Carlo, Francesco
    Thornton, Katsuyo
    Faber, Katherine T.
    ACTA MATERIALIA, 2014, 71 : 126 - 135
  • [35] Laboratory x-ray micro-computed tomography: a user guideline for biological samples
    du Plessis, Anton
    Broeckhoven, Chris
    Guelpa, Anina
    le Roux, Stephan Gerhard
    GIGASCIENCE, 2017, 6 (06):
  • [36] Spatial resolution of drug crystallisation in the skin by X-ray micro-computed tomography
    Goh, Choon Fu
    O'Flynn, Daniel
    Speller, Robert
    Lane, Majella E.
    MICRON, 2021, 145
  • [37] Virtual histology uncertainty in synchrotron x-ray micro-computed tomography evaluation
    Lauridsen, T.
    Feidenhans'l, R.
    Pinholt, E. M.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (09) : 1569 - 1575
  • [38] High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography
    Toledo, J. C.
    Diaz, F., V
    Peralta, M. E.
    Fernandino, D. O.
    FRATTURA ED INTEGRITA STRUTTURALE-FRACTURE AND STRUCTURAL INTEGRITY, 2022, 16 (62): : 279 - 288
  • [39] New developments of high resolution imaging using macro- and micro-computed x-ray tomography
    Engelke, K
    Kalender, W
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (04) : 815 - 815
  • [40] Three-dimensional analysis of cortical bone structure using X-ray micro-computed tomography
    Jones, AC
    Sheppard, AP
    Sok, RM
    Arns, CH
    Limaye, A
    Averdunk, H
    Brandwood, A
    Sakellariou, A
    Senden, TJ
    Milthorpe, BK
    Knackstedt, MA
    PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2004, 339 (1-2) : 125 - 130