摘要
The hole erosion test (HET) was developed to simulate piping erosion and to study the erosion parameters of cohesive soils. The erosion rate in the HET is evaluated by the enlargement of a pre-performed hole in the axis of the specimen with time. The hole diameter during the test is estimated using the pipe flow theory with an assumption that the friction factor varies linearly with time. To investigate this assumption, measurements of the hole diameter during the test are needed. So far, there have been no measurements of the hole diameter during the HET and the hole diameter is measured only at the end of the test after cutting the specimen. In this study, a novel approach to measure the hole diameter at different time steps during the HET using micro-computed X-ray tomography (µCT) is presented. Combining the HET and µCT data, the assumption regarding the friction factor was investigated. Moreover, a linear relation between the flow rate and the hole diameter was found in the range of the tested diameters. This relation was confirmed with HETs using non-erodible PVC specimens with different hole diameters. Accordingly, a new method to interpret the HET for high plastic clay was proposed, in which the hole diameter is calculated based on the flow rate, given that the initial and the final hole diameters are known. A comparison between the analysis of the HET using the proposed and the previous analysis methods is presented.
引用
收藏
页码:865 / 876
页数:11
相关论文
共 50 条
  • [21] LOCATING POROSITY IN CHONDRITES WITH X-RAY MICRO-COMPUTED TOMOGRAPHY (μCT)
    Almeida, N. V.
    Smith, C. L.
    Sykes, D.
    Downes, H.
    Ahmed, F.
    Russell, S. S.
    METEORITICS & PLANETARY SCIENCE, 2014, 49 : A16 - A16
  • [22] Specimen preparation for X-ray micro-computed tomography of forest pests
    Eun Jung Ahn
    Ki Woo Kim
    Applied Microscopy, 55 (1)
  • [23] Investigation of coating layer morphology by micro-computed X-ray tomography
    Sondej, Franziska
    Bueck, Andreas
    Koslowsky, Katharina
    Bachmann, Philipp
    Jacob, Michael
    Tsotsas, Evangelos
    POWDER TECHNOLOGY, 2015, 273 : 165 - 175
  • [24] Ductile fracture evaluated through micro-computed X-ray tomography
    Scheck, Caroline
    Zupan, Marc
    SCRIPTA MATERIALIA, 2011, 65 (12) : 1041 - 1044
  • [25] Fiber orientation quantification utilizing X-ray micro-computed tomography
    Sietins, Jennifer M.
    Sun, Jessica C.
    Knorr, Daniel B., Jr.
    JOURNAL OF COMPOSITE MATERIALS, 2021, 55 (08) : 1109 - 1118
  • [26] High pressure-elevated temperature x-ray micro-computed tomography for subsurface applications
    Iglauer, Stefan
    Lebedev, Maxim
    ADVANCES IN COLLOID AND INTERFACE SCIENCE, 2018, 256 : 393 - 410
  • [27] ANALYSIS OF WOOD PORE CHARACTERISTICS WITH MERCURY INTRUSION POROSIMETRY AND X-RAY MICRO-COMPUTED TOMOGRAPHY
    Peng, Li Min
    Wang, Dong
    Fu, Feng
    Song, Bo Qi
    WOOD RESEARCH, 2015, 60 (06) : 857 - 864
  • [28] Structure Analysis of Pellets with Different Reduction Degrees Using X-Ray Micro-Computed Tomography
    Nie, Hao
    Qi, Bing
    Li, Ying
    Qiu, Dejing
    Wei, Han
    Hammam, Abourehab
    Ahmed, Abdallah
    Yu, Yaowei
    STEEL RESEARCH INTERNATIONAL, 2023, 94 (01)
  • [29] Visualization and numerical analysis of adhesive distribution in particleboard using X-ray micro-computed tomography
    Evans, Philip D.
    Morrison, Olivia
    Senden, Tim J.
    Vollmer, Stephan
    Roberts, Ray J.
    Limaye, Ajay
    Arns, Christoph H.
    Averdunk, Holger
    Lowe, Adrian
    Knackstedt, Mark A.
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2010, 30 (08) : 754 - 762
  • [30] 3D IMAGE RECONSTRUCTION ON X-RAY MICRO-COMPUTED TOMOGRAPHY
    Louk, Andreas C.
    Suparta, Gede B.
    INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS 2014, 2015, 9302