Post-growth Annealing of Cadmium Zinc Telluride Crystals for Room-Temperature Radiation Detectors

被引:0
|
作者
G. Yang
A.E. Bolotnikov
P.M. Fochuk
Y. Cui
G. S. Camarda
A. Hossain
K. H. Kim
J. Horace
B. McCall
R. Gul
O.V. Kopach
S.U. Egarievwe
R.B. James
机构
[1] Brookhaven National Laboratory,
[2] Chernivtsi National University,undefined
[3] Alabama A&M University,undefined
来源
关键词
CZT; post-growth annealing; Te inclusions; resistivity; surface morphology;
D O I
暂无
中图分类号
学科分类号
摘要
We investigated the effects of post-growth annealing on cadmium zinc telluride crystals intended for use as room-temperature radiation detectors. Annealing under Cd vapor effectively eliminated Te inclusions. The material’s resistivity was lowered, and loss of Zn component was observed. Annealing under Cd + Zn vapors similarly removed Te inclusions. Furthermore, after exposure to the two vapors, we noted a change in the crystal surface morphology, i.e., formation of patterns of parallel lines. In contrast to annealing under Cd vapor alone, high resistivity was maintained after suitably controlling the Cd and Zn pressures.
引用
收藏
页码:2912 / 2916
页数:4
相关论文
共 50 条
  • [21] Low-temperature growth and post-growth annealing of GaAsSb
    Sigmund, J
    Hartnagel, HL
    JOURNAL OF CRYSTAL GROWTH, 2005, 278 (1-4) : 209 - 213
  • [22] Ion microbeam studies of cadmium zinc telluride radiation detectors by IBICC
    Sandia National Laboratories, MS 1056, P.O. Box 5800, Albuquerque, NM 87185-1056, United States
    不详
    不详
    不详
    Nucl Instrum Methods Phys Res Sect B, 1 (437-444):
  • [23] Crystal growth, characterization and fabrication of AgGaSe2 crystals as a novel, material for room-temperature radiation detectors
    Roy, UN
    Groza, M
    Cui, YL
    Burger, A
    Bell, ZW
    Carpenter, DA
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS VI, 2004, 5540 : 177 - 180
  • [24] Radiation damage measurements in room-temperature semiconductor radiation detectors
    Franks, Larry A.
    A. Brunett, Bruce
    Olsen, Richard W.
    Walsh, David S.
    Vizkelethy, Gyögy
    I. Trombka, Jacob
    Doyle, Barney L.
    James, Ralph B.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 428 (01): : 95 - 101
  • [25] Radiation damage measurements in room-temperature semiconductor radiation detectors
    Franks, LA
    Brunett, BA
    Olsen, RW
    Walsh, DS
    Vizkelethy, G
    Trombka, JI
    Doyle, BL
    James, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01): : 95 - 101
  • [26] ROOM-TEMPERATURE BAND-EDGE PHOTOLUMINESCENCE FROM CADMIUM TELLURIDE
    LEE, JS
    GILES, NC
    RAJAVEL, D
    SUMMERS, CJ
    PHYSICAL REVIEW B, 1994, 49 (03): : 1668 - 1676
  • [27] Performance comparison of four compact room-temperature detectors -: Two cadmium zinc telluride (CZT) semiconductor detectors, a LaCl3(Ce) scintillator, and an NaI(Tl) scintillator
    Hartwell, JK
    Gehrke, RJ
    Mc Ilwain, ME
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1813 - 1818
  • [28] ROOM-TEMPERATURE GALLIUM-ARSENIDE RADIATION DETECTORS
    BAUSER, E
    CHEN, J
    GEPPERT, R
    IRSIGLER, R
    LAUXTERMANN, S
    LUDWIG, J
    KOHLER, M
    ROGALLA, M
    RUNGE, K
    SCHAFER, F
    SCHMID, T
    SCHOCHLIN, A
    WEBEL, M
    GALLIUM ARSENIDE AND RELATED COMPOUNDS 1993, 1994, 136 (136): : 355 - 360
  • [29] DEVELOPMENT OF BULK GAAS ROOM-TEMPERATURE RADIATION DETECTORS
    MCGREGOR, DS
    KNOLL, GF
    EISEN, Y
    BRAKE, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (05) : 1226 - 1236
  • [30] Chemical etching and surface oxidation studies of cadmium zinc telluride radiation detectors
    Ozsan, M. E.
    Sellin, P. J.
    Veeramani, P.
    Hinder, S. J.
    Monnier, M. L. T.
    Prekas, G.
    Lohstroh, A.
    Baker, M. A.
    SURFACE AND INTERFACE ANALYSIS, 2010, 42 (6-7) : 795 - 798