Simultaneous Determination of Choline and Acetylcholine Based on a Trienzyme Chemiluminometric Biosensor in a Single Line Flow Injection System

被引:0
|
作者
Nobutoshi Kiba
Seiji Ito
Masaki Tachibana
Kazue Tani
Hitoshi Koizumi
机构
[1] University of Yamanashi,Department of Applied Chemistry and Biotechnology, Interdisciplinary Graduate School of Medicine and Engineering
来源
Analytical Sciences | 2003年 / 19卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A detector for the simultaneous determination of choline (Ch) and acetylcholine (ACh) based on a sensitive trienzyme chemiluminometric biosensor in a single line flow injection (FI) system is described. Immobilized choline oxidase (ChOx), immobilized peroxidase (POx), immobilized acetylcholinesterase, and coimmobilized ChOx/POx were packed, in turn, in a transparent ETFE tube (1 mm i.d., 75 cm) and the tube was placed in front of a photomultipier tube as a flow cell. Two-peak response was obtained by one injection of the sample solution. The first and second peaks were dependent on the concentrations of Ch and ACh, respectively. The influence of some experimental parameters such as flow rate, amounts of immobilized enzymes on the behavior of the sensor was studied in order to optimize the sensitivity, sample throughput and resolution. Calibration curves were linear at 1 − 1000 nM for Ch and 3 − 3000 nM for ACh. The sample throughput was 25/h without carryover. The FI system was applied to the simultaneous determination of Ch and ACh in rabbit brain tissue homogenates.
引用
收藏
页码:1647 / 1651
页数:4
相关论文
共 50 条
  • [31] Multienzyme microbiosensor based on electropolymerized o-phenylenediamine for simultaneous in vitro determination of acetylcholine and choline
    Khan, Anish
    Ab Ghani, Sulaiman
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 433 - 438
  • [32] Determination of carbamate pesticides by a cholinesterase-based flow injection biosensor
    Lee, HS
    Kim, YA
    Chung, DH
    Lee, YT
    INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 2001, 36 (03): : 263 - 269
  • [33] On-line biosensors for simultaneous determination of glucose, choline, and glutamate integrated with a microseparation system
    Shi, GY
    Yamamoto, K
    Zhou, TS
    Xu, F
    Kato, T
    Jin, JY
    Jin, LT
    ELECTROPHORESIS, 2003, 24 (18) : 3266 - 3272
  • [34] Dual electrode signal-subtracted biosensor for simultaneous flow injection determination of sucrose and glucose
    Surareungchai, W
    Worasing, S
    Sritongkum, P
    Tanticharoen, M
    Kirtikara, K
    ANALYTICA CHIMICA ACTA, 1999, 380 (01) : 7 - 15
  • [35] Amperometric bienzymatic biosensor in flow injection analysis system for determination of aspartame in foods
    Tanaporn Tangtawewipat
    Saipin Thanachasai
    Food Science and Biotechnology, 2024, 33 : 343 - 354
  • [36] Determination of S-perindopril using a flow injection system with an amperometric biosensor
    Stefan, RI
    van Staden, JKF
    Aboul-Enein, HY
    SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (03) : 261 - 265
  • [37] Amperometric bienzymatic biosensor in flow injection analysis system for determination of aspartame in foods
    Tangtawewipat, Tanaporn
    Thanachasai, Saipin
    FOOD SCIENCE AND BIOTECHNOLOGY, 2024, 33 (02) : 343 - 354
  • [38] SEQUENTIAL FLOW-INJECTION SPECTROFLUOROMETRIC DETERMINATION OF COUMARINS USING A DOUBLE-INJECTION SINGLE-LINE SYSTEM
    SOLICH, P
    POLASEK, M
    KARLICEK, R
    ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) : 293 - 298
  • [39] DIRECT AND SIMULTANEOUS DETERMINATION OF URIC-ACID AND GLUCOSE IN SERUM WITH ELECTROCHEMICAL FILTER/BIOSENSOR FLOW-INJECTION ANALYSIS SYSTEM
    OKAWA, Y
    KOBAYASHI, H
    OHNO, T
    ANALYTICA CHIMICA ACTA, 1995, 315 (1-2) : 137 - 143
  • [40] Flow amperometric biosensor based on two enzymatic reactors (acetylcholinesterase-choline oxidase) for the detection of neurotransmitter acetylcholine
    Tvorynska, Sofiia
    Barek, Jiri
    Josypcuk, Bohdan
    PROCEEDINGS OF THE 15TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2019, : 61 - 66