Numerical evaluation of the directed oil cooling system of a mobile power transformer

被引:0
|
作者
Luciene Martins Moura
Rudolf Huebner
Paulo Vinicius Trevizoli
机构
[1] Federal University of Minas Gerais (UFMG),Department of Mechanical Engineering
关键词
Power transformer; Oil cooling system; Overheating; Hot spot; CFD;
D O I
暂无
中图分类号
学科分类号
摘要
Power transformers represent an important part of the capital investment in transmission and distribution substations. The cooling of the windings (electrical coil) depends on the convection of heat, enhanced by the forced circulation of oil through the windings and heat exchangers. The forced circulation of oil combined with the forced circulation of air in the heat exchangers is usually found in mobile transformers, whose compact structure is a challenge in terms of heat transfer rates. An improper design or fabrication problem associated with the assembling of the cooling system may result in an inefficient exchange of heat, which may lead to transformer failure from overheating or a reduction of the life span. In this context, the present work proposes a 2D mathematical model to simulate the winding cooling system of a 138 × 69–34 × 13.8 kV 25 MVA Mobile Power Transformer with the objective of investigating the causes of overheating. The model is implemented in CFD Ansys-Fluent® version 17.0 and validated with experimental data. It is evaluated the velocity and temperature distribution, and the identification of the hot spots on the transformer operating considering the nominal conditions for oil flow rate, inlet temperature, and power dissipated. The hot spot temperatures are compared with the current Brazilian Association of Technical Standards—NBR 5356-2: 2007 Power Transformers Part 2: Heating. After, some geometric and/or operational constraints are artificially imposed on the transformer. Their impact on the velocity and temperature fields, as well as the hot spot temperatures, are mapped in order to verify if they still respect the standard´s temperature limits and if imposed constraints may lead to the transformer failure. The numerical results clearly illustrate that geometric imperfections in the disks, guides, or axial cooling ducts have a direct impact on oil flow and temperature distributions. These imperfections can also alter the positioning and significantly increase the temperature of the hottest spot within the winding, sometimes even exceeding the requirements of the ABNT NBR 5356:2 standard in certain scenarios. Therefore, the proposed mathematical model serves as a valuable tool for investigating a complex and common issue within the energy distribution system. This issue not only inconveniences the population but also leads to economic challenges each year. Finally, the outcomes of this study can provide engineers with essential insights to enhance the thermal design of power transformers, as well it can assist in guiding maintenance efforts and understanding the root causes of new failures.
引用
收藏
相关论文
共 50 条
  • [41] Method for the Evaluation and Classification of Power Transformer Insulating Oil Based on Physicochemical Analyses
    Marques, Andre Pereira
    de Moura, Nicolas Kemerich
    Dias, Yuri Andrade
    Ribeiro, Cacilda de Jesus
    Rocha, Adson Silva
    Brito, Leonardo da Cunha
    Bezerra Azevedo, Claudio Henrique
    Lopes dos Santos, Jose Augusto
    IEEE ELECTRICAL INSULATION MAGAZINE, 2017, 33 (01) : 39 - 49
  • [42] Online Evaluation of Power Transformer Temperatures Using Magnetic and Thermodynamics Numerical Modeling
    da Silva, Juliano R.
    Bastos, Joao P. A.
    IEEE TRANSACTIONS ON MAGNETICS, 2017, 53 (06)
  • [43] Analytical evaluation of blocking probability in a mobile radio system with directed retry
    Verdone, R
    Zanella, A
    IEEE JOURNAL ON SELECTED AREAS IN COMMUNICATIONS, 2001, 19 (02) : 322 - 331
  • [44] Determination of OD cooling system parameters based on thermal modeling of power transformer winding
    Hosseini, R.
    Nourolahi, M.
    Gharehpetian, G. B.
    SIMULATION MODELLING PRACTICE AND THEORY, 2008, 16 (06) : 585 - 596
  • [45] A fuzzy regulator of power oil-immersed transformer cooling on the basis of disturbance factor change prediction
    Polyakov, M. A.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2007, (03) : 47 - +
  • [46] RESEARCH ON TRANSFORMER'S FORCED-OIL-AIR COOLING CONTROL SYSTEM BASED ON PCC
    PROCEEDINGS OF 2009 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-6, 2009, : 1978 - 1983
  • [47] Applying Response Surface Method to Oil-Immersed Transformer Cooling System for Design Optimization
    Zhang, Yunpeng
    Ho, S. L.
    Fu, Weinong
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (11)
  • [48] Design and realization of a new transformer's forced-oil-air cooling control system
    Liu Shuguang
    Xi Zhen
    Proceedings of the First International Symposium on Test Automation & Instrumentation, Vols 1 - 3, 2006, : 1702 - 1707
  • [49] Transformer insulation-based vegetable seed oil for power system analysis
    Karthik, M.
    Narmadhai, N.
    BIOMASS CONVERSION AND BIOREFINERY, 2024, : 21565 - 21578
  • [50] Numerical investigations of the engine cooling system in a small power vessel pod propulsion system
    Dymarski, Czeslaw
    Lesniewski, Wojciech
    POLISH MARITIME RESEARCH, 2008, 15 (04) : 59 - 65