Numerical evaluation of the directed oil cooling system of a mobile power transformer

被引:0
|
作者
Luciene Martins Moura
Rudolf Huebner
Paulo Vinicius Trevizoli
机构
[1] Federal University of Minas Gerais (UFMG),Department of Mechanical Engineering
关键词
Power transformer; Oil cooling system; Overheating; Hot spot; CFD;
D O I
暂无
中图分类号
学科分类号
摘要
Power transformers represent an important part of the capital investment in transmission and distribution substations. The cooling of the windings (electrical coil) depends on the convection of heat, enhanced by the forced circulation of oil through the windings and heat exchangers. The forced circulation of oil combined with the forced circulation of air in the heat exchangers is usually found in mobile transformers, whose compact structure is a challenge in terms of heat transfer rates. An improper design or fabrication problem associated with the assembling of the cooling system may result in an inefficient exchange of heat, which may lead to transformer failure from overheating or a reduction of the life span. In this context, the present work proposes a 2D mathematical model to simulate the winding cooling system of a 138 × 69–34 × 13.8 kV 25 MVA Mobile Power Transformer with the objective of investigating the causes of overheating. The model is implemented in CFD Ansys-Fluent® version 17.0 and validated with experimental data. It is evaluated the velocity and temperature distribution, and the identification of the hot spots on the transformer operating considering the nominal conditions for oil flow rate, inlet temperature, and power dissipated. The hot spot temperatures are compared with the current Brazilian Association of Technical Standards—NBR 5356-2: 2007 Power Transformers Part 2: Heating. After, some geometric and/or operational constraints are artificially imposed on the transformer. Their impact on the velocity and temperature fields, as well as the hot spot temperatures, are mapped in order to verify if they still respect the standard´s temperature limits and if imposed constraints may lead to the transformer failure. The numerical results clearly illustrate that geometric imperfections in the disks, guides, or axial cooling ducts have a direct impact on oil flow and temperature distributions. These imperfections can also alter the positioning and significantly increase the temperature of the hottest spot within the winding, sometimes even exceeding the requirements of the ABNT NBR 5356:2 standard in certain scenarios. Therefore, the proposed mathematical model serves as a valuable tool for investigating a complex and common issue within the energy distribution system. This issue not only inconveniences the population but also leads to economic challenges each year. Finally, the outcomes of this study can provide engineers with essential insights to enhance the thermal design of power transformers, as well it can assist in guiding maintenance efforts and understanding the root causes of new failures.
引用
收藏
相关论文
共 50 条
  • [31] Fans arrangement analysis in oil forced air natural cooling method of power transformer radiator
    Taghikhani, Mohammad Ali
    Afshar, Mohammad Reza
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2021, 235 (04) : 904 - 913
  • [32] Study on Control Strategy of Cooling System for Oil Immersed Air-cooled Transformer
    Yao, Chuang
    Liu, LiQing
    Feng, JunJi
    Wei, JuFang
    Liu, Guangzhen
    Zhang, Xin
    Duan, MingHui
    Zhang, He
    2022 9TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2022, : 558 - 561
  • [33] Development of Weather Invariant Electric Power Transformer Oil Purification System
    Roycroft, C. D.
    Yusuff, A. A.
    2021 SOUTHERN AFRICAN UNIVERSITIES POWER ENGINEERING CONFERENCE/ROBOTICS AND MECHATRONICS/PATTERN RECOGNITION ASSOCIATION OF SOUTH AFRICA (SAUPEC/ROBMECH/PRASA), 2021,
  • [34] Experimental and Numerical Investigation of the Internal Temperature of an Oil-Immersed Power Transformer with DOFS
    Liu, Yunpeng
    Li, Xinye
    Li, Huan
    Wang, Jiaxue
    Fan, Xiaozhou
    APPLIED SCIENCES-BASEL, 2020, 10 (16):
  • [35] An investigation of power transformer cooling with magnetic fluids
    Segal, V
    Raj, K
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 1998, 5 (06) : 416 - 422
  • [36] Reliability model of the power transformer with ONAF cooling
    Sefidgaran, Mobin
    Mirzaie, Mohammad
    Ebrahimzadeh, Ataollah
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 35 (01) : 97 - 104
  • [37] Modernization of Power-Transformer Cooling Systems
    Yakimov N.D.
    Dmitrieva O.S.
    Russian Electrical Engineering, 2018, 89 (6) : 367 - 370
  • [38] A Study on Optimizing Cooling Design for a Power Transformer
    Kim, Seong Eon
    Ryu, Jae Seop
    2023 29TH INTERNATIONAL WORKSHOP ON THERMAL INVESTIGATIONS OF ICS AND SYSTEMS, THERMINIC, 2023,
  • [39] Assessment of numerical models in the evaluation of adsorption cooling system performance
    Mohammed, Ramy H.
    Mesalhy, Osama
    Elsayed, Mohamed L.
    Chow, Louis C.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 99 : 166 - 175
  • [40] Dynamic Thermal Model for Oil Directed Air Forced Power Transformers With Cooling Stage Representation
    Paulhiac, Luc
    Desquiens, Remi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (05) : 4135 - 4144