Numerical evaluation of the directed oil cooling system of a mobile power transformer

被引:0
|
作者
Luciene Martins Moura
Rudolf Huebner
Paulo Vinicius Trevizoli
机构
[1] Federal University of Minas Gerais (UFMG),Department of Mechanical Engineering
关键词
Power transformer; Oil cooling system; Overheating; Hot spot; CFD;
D O I
暂无
中图分类号
学科分类号
摘要
Power transformers represent an important part of the capital investment in transmission and distribution substations. The cooling of the windings (electrical coil) depends on the convection of heat, enhanced by the forced circulation of oil through the windings and heat exchangers. The forced circulation of oil combined with the forced circulation of air in the heat exchangers is usually found in mobile transformers, whose compact structure is a challenge in terms of heat transfer rates. An improper design or fabrication problem associated with the assembling of the cooling system may result in an inefficient exchange of heat, which may lead to transformer failure from overheating or a reduction of the life span. In this context, the present work proposes a 2D mathematical model to simulate the winding cooling system of a 138 × 69–34 × 13.8 kV 25 MVA Mobile Power Transformer with the objective of investigating the causes of overheating. The model is implemented in CFD Ansys-Fluent® version 17.0 and validated with experimental data. It is evaluated the velocity and temperature distribution, and the identification of the hot spots on the transformer operating considering the nominal conditions for oil flow rate, inlet temperature, and power dissipated. The hot spot temperatures are compared with the current Brazilian Association of Technical Standards—NBR 5356-2: 2007 Power Transformers Part 2: Heating. After, some geometric and/or operational constraints are artificially imposed on the transformer. Their impact on the velocity and temperature fields, as well as the hot spot temperatures, are mapped in order to verify if they still respect the standard´s temperature limits and if imposed constraints may lead to the transformer failure. The numerical results clearly illustrate that geometric imperfections in the disks, guides, or axial cooling ducts have a direct impact on oil flow and temperature distributions. These imperfections can also alter the positioning and significantly increase the temperature of the hottest spot within the winding, sometimes even exceeding the requirements of the ABNT NBR 5356:2 standard in certain scenarios. Therefore, the proposed mathematical model serves as a valuable tool for investigating a complex and common issue within the energy distribution system. This issue not only inconveniences the population but also leads to economic challenges each year. Finally, the outcomes of this study can provide engineers with essential insights to enhance the thermal design of power transformers, as well it can assist in guiding maintenance efforts and understanding the root causes of new failures.
引用
收藏
相关论文
共 50 条
  • [1] Numerical evaluation of the directed oil cooling system of a mobile power transformer
    Moura, Luciene Martins
    Huebner, Rudolf
    Trevizoli, Paulo Vinicius
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2024, 46 (04)
  • [2] A numerical study of the effect of a hybrid cooling system on the cooling performance of a large power transformer
    Kim, Young Joo
    Jeong, Myunggeun
    Park, Yong Gap
    Ha, Man Yeong
    APPLIED THERMAL ENGINEERING, 2018, 136 : 275 - 286
  • [3] CALCULATION OF THE FORCED, DIRECTED OIL-CIRCULATION RATE THROUGH A TRANSFORMER COOLING SYSTEM
    PIVRNEC, M
    ALLEN, PHG
    HAVLICEK, K
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1987, 134 (04) : 306 - 312
  • [4] Prediction of hottest spot temperature in power transformer windings with non-directed and directed oil-forced cooling
    Taghikhani, M. A.
    Gholami, A.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2009, 31 (7-8) : 356 - 364
  • [5] POWER TRANSFORMER COOLING SYSTEM OPTIMIZATION
    Arifianto, Indera
    Cahyono, Bambang
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 57 - +
  • [6] Ratings of Oil Power Transformer in Different Cooling Modes
    Radakovic, Zoran
    Sorgic, Marko
    Van der Veken, Wim
    Claessens, Gert
    IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (02) : 618 - 625
  • [7] Numerical study of cooling solutions inside a power transformer
    Chereches, Nelu-Cristian
    Chereches, Monica
    Miron, Livia
    Hudisteanu, Sebastian
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT, EENVIRO 2016, 2017, 112 : 314 - 321
  • [8] Design of Smart Cooling System for Power Transformer
    Khan, Waheed Aftab
    Ellahi, Manzoor
    Masood, Bilal
    Usman, Fuad
    Abbass, Ghulam
    2018 INTERNATIONAL CONFERENCE ON ENGINEERING & EMERGING TECHNOLOGIES (ICEET), 2018, : 170 - 176
  • [9] Heat Transfer Study in Oil Channels of a Transformer ODAF Cooling System based on Numerical Modeling
    Salaria, Sina
    Noasrolahzadeh, M. Reza
    Parsimoghadam, Azadeh
    Khalilikhah, Mostafa
    4TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2011), PT 1 AND 2, 2012, 1440 : 255 - 260
  • [10] Oil-Forced Versus Oil-Directed Cooling of Power Transformers
    Sorgic, Marko
    Radakovic, Zoran
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) : 2590 - 2598