Virtual monoenergetic micro-CT imaging in mice with artificial intelligence

被引:0
|
作者
Brent van der Heyden
Stijn Roden
Rüveyda Dok
Sandra Nuyts
Edmond Sterpin
机构
[1] KU Leuven,Department of Oncology, Laboratory of Experimental Radiotherapy
[2] UCLouvain,Institut de Recherche Expérimentale Et Clinique, Molecular Imaging Radiotherapy and Oncology Lab
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Micro cone-beam computed tomography (µCBCT) imaging is of utmost importance for carrying out extensive preclinical research in rodents. The imaging of animals is an essential step prior to preclinical precision irradiation, but also in the longitudinal assessment of treatment outcomes. However, imaging artifacts such as beam hardening will occur due to the low energetic nature of the X-ray imaging beam (i.e., 60 kVp). Beam hardening artifacts are especially difficult to resolve in a ‘pancake’ imaging geometry with stationary source and detector, where the animal is rotated around its sagittal axis, and the X-ray imaging beam crosses a wide range of thicknesses. In this study, a seven-layer U-Net based network architecture (vMonoCT) is adopted to predict virtual monoenergetic X-ray projections from polyenergetic X-ray projections. A Monte Carlo simulation model is developed to compose a training dataset of 1890 projection pairs. Here, a series of digital anthropomorphic mouse phantoms was derived from the reference DigiMouse phantom as simulation geometry. vMonoCT was trained on 1512 projection pairs (= 80%) and tested on 378 projection pairs (= 20%). The percentage error calculated for the test dataset was 1.7 ± 0.4%. Additionally, the vMonoCT model was evaluated on a retrospective projection dataset of five mice and one frozen cadaver. It was found that beam hardening artifacts were minimized after image reconstruction of the vMonoCT-corrected projections, and that anatomically incorrect gradient errors were corrected in the cranium up to 15%. Our results disclose the potential of Artificial Intelligence to enhance the µCBCT image quality in biomedical applications. vMonoCT is expected to contribute to the reproducibility of quantitative preclinical applications such as precision irradiations in X-ray cabinets, and to the evaluation of longitudinal imaging data in extensive preclinical studies.
引用
收藏
相关论文
共 50 条
  • [41] Virtual monoenergetic imaging in photon-counting CT of the head and neck
    Farhadi, Faraz
    Sahbaee, Pooyan
    Rajagopal, Jayasai R.
    Nikpanah, Moozhan
    Saboury, Babak
    Gutjahr, Ralf
    Biassou, Nadia M.
    Shah, Ritu
    Flohr, Thomas G.
    Samei, Ehsan
    Pritchard, William F.
    Malayeri, Ashkan A.
    Bluemke, David A.
    Jones, Elizabeth C.
    CLINICAL IMAGING, 2023, 102 : 109 - 115
  • [42] Quantitative micro-CT
    Schladitz, K.
    JOURNAL OF MICROSCOPY, 2011, 243 (02) : 111 - 117
  • [43] Novel Micro-CT Method To Assess Atherosclerotic Calcification In Mice
    Kaur, Jashandeep
    Carpo, Beatrice
    Kosciuszek, Nina D.
    Singh, Mohnish
    Savinova, Olga V.
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2021, 41
  • [44] Double-contrast micro-CT colonoscopy in live mice
    Hanne Boll
    Simona Bag
    Ingo S. Nölte
    Thomas Wilhelm
    Martin Kramer
    Christoph Groden
    Ulrich Böcker
    Marc A. Brockmann
    International Journal of Colorectal Disease, 2011, 26 : 721 - 727
  • [45] RAPID PHENOTYPING OF GENITOURINARY ANOMALIES IN MICE USING MICRO-CT
    Huang, Gene
    O'Neill, Marisol
    Haller, Meade
    Jorgez, Carolina
    Lamb, D. J.
    JOURNAL OF UROLOGY, 2017, 197 (04): : E99 - E99
  • [46] Double-contrast micro-CT colonoscopy in live mice
    Boll, Hanne
    Bag, Simona
    Noelte, Ingo S.
    Wilhelm, Thomas
    Kramer, Martin
    Groden, Christoph
    Boecker, Ulrich
    Brockmann, Marc A.
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2011, 26 (06) : 721 - 727
  • [47] Micro-imaging of implanted scaffolds using combined MRI and micro-CT
    Klodowski, K.
    Kaminski, J.
    Nowicka, K.
    Tarasiuk, J.
    Wronski, S.
    Swietek, M.
    Blazewicz, M.
    Figiel, H.
    Turek, K.
    Szponder, T.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2014, 38 (06) : 458 - 468
  • [48] Ethanol fixation method for heart and lung imaging in micro-CT
    Patzelt, Matej
    Mrzilkova, Jana
    Dudak, Jan
    Krejci, Frantisek
    Zemlicka, Jan
    Karch, Jakub
    Musil, Vladimir
    Rosina, Jozef
    Sykora, Viktor
    Horehledova, Barbora
    Zach, Petr
    JAPANESE JOURNAL OF RADIOLOGY, 2019, 37 (06) : 500 - 510
  • [49] In vivo micro-CT imaging of untreated and irradiated orthotopic glioblastoma xenografts in mice: capabilities, limitations and a comparison with bioluminescence imaging
    Kirschner, Stefanie
    Felix, Manuela C.
    Hartmann, Linda
    Bierbaum, Miriam
    Maros, Mate E.
    Kerl, Hans U.
    Wenz, Frederik
    Glatting, Gerhard
    Kramer, Martin
    Giordano, Frank A.
    Brockmann, Marc A.
    JOURNAL OF NEURO-ONCOLOGY, 2015, 122 (02) : 245 - 254
  • [50] High Resolution Spectral Micro-CT Imaging of Atherosclerotic Plaque
    Zainon, R.
    Butler, P. H.
    Gieseg, S. P.
    Janmale, T.
    Ronaldson, J. P.
    Anderson, N. G.
    Butler, A. P. H.
    Scott, N. J.