Virtual monoenergetic imaging in photon-counting CT of the head and neck

被引:4
|
作者
Farhadi, Faraz [1 ]
Sahbaee, Pooyan [2 ]
Rajagopal, Jayasai R. [1 ,3 ]
Nikpanah, Moozhan [1 ]
Saboury, Babak [1 ]
Gutjahr, Ralf [4 ]
Biassou, Nadia M. [1 ]
Shah, Ritu [1 ]
Flohr, Thomas G. [4 ]
Samei, Ehsan [3 ]
Pritchard, William F. [1 ,5 ]
Malayeri, Ashkan A. [1 ]
Bluemke, David A. [6 ]
Jones, Elizabeth C. [1 ]
机构
[1] NIH, Radiol & Imaging Sci, Clin Ctr, 10 Ctr Dr,Room 1C355,MSC 1182, Bethesda, MD 20892 USA
[2] Siemens Med Solut USA, Malvern, PA USA
[3] Duke Univ, Med Ctr, Dept Radiol, Carl E Ravin Adv Imaging Labs, Durham, NC USA
[4] Siemens Healthineers, Forchheim, Germany
[5] NIH, Ctr Intervent Oncol Radiol & Imaging Sci, Clin Ctr, Bethesda, MD 20892 USA
[6] Univ Wisconsin, Dept Radiol, Madison, WI USA
关键词
Photon counting CT; Virtual monoenergetic imaging; Head and neck CT; Visual grading characteristic; COMPUTED-TOMOGRAPHY; DUAL-SOURCE; IMAGES; OPTIMIZATION; SETTINGS; NOISE;
D O I
10.1016/j.clinimag.2023.08.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Advantages of virtual monoenergetic images (VMI) have been reported for dual energy CT of the head and neck, and more recently VMIs derived from photon-counting (PCCT) angiography of the head and neck. We report image quality metrics of VMI in a PCCT angiography dataset, expanding the anatomical regions evaluated and extending observer-based qualitative methods further than previously reported.Methods: In a prospective study, asymptomatic subjects underwent contrast enhanced PCCT of the head and neck using an investigational scanner. Image sets of low, high, and full spectrum (Threshold-1) energies; linear mix of low and high energies (Mix); and 23 VMIs (40-150 keV, 5 keV increments) were generated. In 8 anatomical locations, SNR and radiologists' preferences for VMI energy levels were measured using a forced-choice rank method (4 observers) and ratings of image quality using visual grading characteristic (VGC) analysis (2 observers) comparing VMI to Mix and Threshold-1 images.Results: Fifteen subjects were included (7 men, 8 women, mean 57 years, range 46-75). Among all VMIs, SNRs varied by anatomic location. The highest SNRs were observed in VMIs. Radiologists preferred 50-60 keV VMIs for vascular structures and 75-85 keV for all other structures. Cumulative ratings of image quality averaged across all locations were higher for VMIs with areas under the curve of VMI vs Mix and VMI vs Threshold-1 of 0.67 and 0.68 for the first reader and 0.72 and 0.76 for the second, respectively.Conclusion: Preferred keV level and quality ratings of VMI compared to mixed and Threshold-1 images varied by anatomical location.
引用
收藏
页码:109 / 115
页数:7
相关论文
共 50 条
  • [1] Image quality of photon-counting detector CT virtual monoenergetic and polyenergetic reconstructions for head and neck CT angiography
    Spampinato, Maria Vittoria
    Rodgers, Jeffrey
    McGill, Liam J.
    Schoepf, Uwe Joseph
    O'Doherty, Jim
    CLINICAL IMAGING, 2024, 108
  • [2] Impact of CT Photon-Counting Virtual Monoenergetic Imaging on Visualization of Abdominal Arterial Vessels
    Dillinger, Daniel
    Overhoff, Daniel
    Booz, Christian
    Kaatsch, Hanns L.
    Piechotka, Joel
    Hagen, Achim
    Froelich, Matthias F.
    Vogl, Thomas J.
    Waldeck, Stephan
    DIAGNOSTICS, 2023, 13 (05)
  • [3] Photon Counting CT Angiography of the Head and Neck: Image Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions
    Michael, Arwed Elias
    Boriesosdick, Jan
    Schoenbeck, Denise
    Lopez-Schmidt, Ingo
    Kroeger, Jan Robert
    Moenninghoff, Christoph
    Horstmeier, Sebastian
    Pennig, Lenhard
    Borggrefe, Jan
    Niehoff, Julius Henning
    DIAGNOSTICS, 2022, 12 (06)
  • [4] Virtual Noncontrast Abdominal Imaging with Photon-counting Detector CT
    Mergen, Victor
    Racine, Damien
    Jungblut, Lisa
    Sartoretti, Thomas
    Bickel, Steven
    Monnin, Pascal
    Higashigaito, Kai
    Martini, Katharina
    Alkadhi, Hatem
    Euler, Andre
    RADIOLOGY, 2022, 305 (01) : 106 - 114
  • [5] Photon-Counting CT in the Head and Neck: Current Applications and Future Prospects
    Benson, John C.
    Campeau, Norbert G.
    Diehn, Felix E.
    Lane, John I.
    Leng, Shuai
    Moonis, Gul
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (08) : 1000 - 1005
  • [6] A review of applications of photon-counting computed tomography in head and neck imaging
    Dogra, Siddhant
    Shekhrajka, Nitesh
    Moonis, Gul
    BRITISH JOURNAL OF RADIOLOGY, 2024,
  • [7] Photon-counting CT in lung imaging
    Tarnoki, adam Domonkos
    Tarnoki, David Laszlo
    Maurovich-Horvat, Pal
    EXPERT REVIEW OF RESPIRATORY MEDICINE, 2025, 19 (02) : 77 - 81
  • [8] Photon-counting Detector CT: Initial Analysis of Virtual Noncontrast Imaging
    Sosna, Jacob
    RADIOLOGY, 2022, 305 (01) : 115 - 116
  • [9] Photon-counting CT to Virtual Noncontrast CT Images
    Pourmorteza, Amir
    RADIOLOGY, 2023, 306 (01) : 205 - 206
  • [10] Editorial Comment: Optimizing Imaging With Photon-Counting Detector CTA of the Head and Neck
    Hung, Sheng-Che
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2025, 224 (01)