Strip-loaded Mach-Zehnder interferometer for absolute refractive index sensing

被引:4
|
作者
Doughan, Isaac [1 ]
Oyemakinwa, Kehinde [1 ]
Ovaskainen, Olli [1 ]
Roussey, Matthieu [1 ]
机构
[1] Univ Eastern Finland, Ctr Photon Sci, Dept Phys & Math, Joensuu 80101, Finland
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
基金
芬兰科学院;
关键词
OPTICAL WAVE-GUIDES; LATERAL CONFINEMENT; BOUNDARY-CONDITION; Y-BRANCH; DESIGN;
D O I
10.1038/s41598-024-53326-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper presents the design, fabrication, and characterization of a Mach-Zehnder interferometer (MZI) on a strip-loaded platform specifically developed for the measurement of refractive index variations in liquids. A novel approach of large opening in the sensing region enhances the sensitivity by using the analyte as the loading strip. This allows surpassing the performances of the conventional perforations and trenched-based MZIs and prevent protecting the reference arm. The implementation of this design resulted in a high confinement factor of approximately 23%\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\%$$\end{document} in the cladding, enabling an effective interaction between the evanescent field and analyte. Ethanol-water solutions with varying concentrations were used as analyte for the characterization of the device. The strip-loaded waveguide was a 200 nm TiO2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_2$$\end{document} thin film on a silicon dioxide wafer and a 1.2 mu\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu $$\end{document}m wide for 800 nm-thick nLOF resist served as loading strip. The sensing area featured a 10 mu\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu $$\end{document}m wide open-ing in the loading material with a sensing length of 5 mm. The homogeneous sensitivity was experimentally determined to be 0.128, demonstrating the effectiveness of the proposed design, which enabled a refractive index change monitoring of 10-6\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<^>{-6}$$\end{document}.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Comparative Analyses of Bi-Tapered Fiber Mach-Zehnder Interferometer for Refractive Index Sensing
    Wang, Qi
    Wang, Bo-Tao
    Kong, Ling-Xin
    Zhao, Yong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (09) : 2483 - 2489
  • [22] Refractive index sensing characteristics of a Mach-Zehnder interferometer based on directly photonic crystal fiber
    Bi, Weihong
    Shen, Yuan
    Liu, Qiang
    Fu, Guangwei
    Fu, Xinghu
    Ji, Yushen
    Zhongguo Jiguang/Chinese Journal of Lasers, 2014, 41 (05):
  • [23] Tapered Photonic Crystal Fiber Based Mach-Zehnder Interferometer for Enhanced Refractive Index Sensing
    Ahmed, Farid
    Jun, Martin B. G.
    2015 IEEE SENSORS, 2015, : 1355 - 1358
  • [24] A Mach-Zehnder interferometer based on tapered dual side hole fiber for refractive index sensing
    Li, Song
    Zhao, Yujia
    OPTICAL FIBER TECHNOLOGY, 2018, 45 : 267 - 270
  • [25] High sensitive Mach-Zehnder interferometer for seawater refractive index measurement
    Mu, Xiaoguang
    Yang, Yuqiang
    Wang, Ji
    Bi, Lei
    FERROELECTRICS, 2022, 595 (01) : 27 - 34
  • [26] Refractive-index measurements using an integrated Mach-Zehnder interferometer
    Schubert, T
    Haase, N
    Kuck, H
    GottfriedGottfried, R
    SENSORS AND ACTUATORS A-PHYSICAL, 1997, 60 (1-3) : 108 - 112
  • [27] The Highly Sensitive Refractive Index Sensing of Seawater Based on a Large Lateral Offset Mach-Zehnder Interferometer
    Zhou, Jingwen
    Sun, Yue
    Liu, Haodong
    Li, Haibin
    Wang, Yuye
    Jiang, Junfeng
    Xu, Degang
    Yao, Jianquan
    SENSORS, 2024, 24 (12)
  • [28] PCF taper-based Mach-Zehnder interferometer for refractive index sensing in a PDMS detection cell
    Wu, Di
    Zhao, Yong
    Li, Jin
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 1 - 4
  • [29] 3D Printing Optofluidic Mach-Zehnder Interferometer on a Fiber Tip for Refractive Index Sensing
    Zhang, Dengwei
    Wei, Heming
    Krishnaswamy, Sridhar
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2019, 31 (21) : 1725 - 1728
  • [30] Photonic crystal fiber Mach-Zehnder interferometer with microholes ablated by a femtosecond laser for refractive index sensing
    吴鸿宾
    赵龙江
    王鹏
    曹志涛
    Journal of Beijing Institute of Technology, 2016, 25 (01) : 77 - 80