Glucose oxidase immobilized macro porous silicon based conductive glucose sensor

被引:0
|
作者
Tanusree Sarkar
Nandini Mukherjee
Jayoti Das
机构
[1] Jadavpur University,Department of Computer Science and Engineering
[2] Jadavpur University,Department of Physics
来源
Applied Physics A | 2022年 / 128卷
关键词
Biosensor; Conductivity measurement; Glucose oxidase; Glucose sensor; Macro porous silicon;
D O I
暂无
中图分类号
学科分类号
摘要
Conductive glucose sensor using glucose oxidase immobilized macro porous silicon has been studied in this paper. Macro porous silicon layer is grown on p-type silicon substrate by electrochemical etching process. Two electrodes have been made with silver on front side of the macro porous silicon layer. Then the macro porous silicon surface has been functionalized for efficient glucose sensing by physisorption of glucose oxidase. Current–voltage characteristics have been studied at different glucose concentrations. Current value initially increases due to adsorption of glucose molecules upto 1 mM glucose concentration, after that current value decreases with increasing glucose concentration. Sensor response has been analysed with the help of different types of conduction mechanisms like hopping, Poole–Frenkel, trap-assisted and Fowler–Nordheim tunneling. Different conduction mechanisms are dominating at different applied field ranges. The sensor shows good response, high sensitivity and excellent repetitive behavior.
引用
收藏
相关论文
共 50 条
  • [1] Glucose oxidase immobilized macro porous silicon based conductive glucose sensor
    Sarkar, Tanusree
    Mukherjee, Nandini
    Das, Jayoti
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2022, 128 (04):
  • [2] Glucose Sensor Based on Glucose Oxidase Immobilized by Zirconium Phosphate
    Sejin Park
    Taek Dong Chung
    Sun Kil Kang
    Ran-A Jeong
    Hankil Boo
    Hee Chan Kim
    Analytical Sciences, 2004, 20 : 1635 - 1638
  • [3] Glucose sensor based on glucose oxidase immobilized by zirconium phosphate
    Park, SJ
    Chung, TD
    Kang, SK
    Jeong, RA
    Boo, HK
    Kim, HC
    ANALYTICAL SCIENCES, 2004, 20 (12) : 1635 - 1638
  • [4] Frequency response of the glucose sensor based on immobilized glucose oxidase membrane
    Gondo, S
    Kim, C
    Morishita, M
    Kawakami, M
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1996, 57-8 : 877 - 884
  • [5] GLUCOSE SENSOR WITH IMMOBILIZED GLUCOSE OXIDASE-GLUCOSE ISOMERASE MEMBRANE
    GONDO, S
    OSAKI, T
    MORISHITA, M
    JOURNAL OF MOLECULAR CATALYSIS, 1981, 12 (03): : 365 - 374
  • [6] Amperometric glucose sensor based on glucose oxidase immobilized in electrochemically generated poly(ethacridine)
    Xu, JJ
    Chen, HY
    ANALYTICA CHIMICA ACTA, 2000, 423 (01) : 101 - 106
  • [7] A glucose sensor fabricated on glass substrate with glucose oxidase immobilized technique
    Wu, Tasai-Chen
    Lin, Ting-Qian
    Hsu, Cheng-Chih
    Lee, Ju-Yi
    2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, : 979 - 981
  • [8] A glucose biosensor based on glucose oxidase immobilized on three-dimensional porous carbon electrodes
    Chen, Jingyi
    Zhu, Rong
    Huang, Jia
    Zhang, Man
    Liu, Hongyu
    Sun, Min
    Wang, Li
    Song, Yonghai
    ANALYST, 2015, 140 (16) : 5578 - 5584
  • [9] IMPROVEMENT OF GLUCOSE SENSOR PERFORMANCE WITH IMMOBILIZED GLUCOSE OXIDASE-GLUCOSE ISOMERASE SYSTEM
    GONDO, S
    MORISHITA, M
    OSAKI, T
    BIOTECHNOLOGY AND BIOENGINEERING, 1980, 22 (06) : 1287 - 1291
  • [10] AN ENZYMATIC GLUCOSE SENSOR BASED ON GLUCOSE OXIDASE IMMOBILIZED CUP-STACKED CARBON NANOFILAMENTS
    Akiyama, Shingo
    Toyoda, Momoko
    Nakagawa, Kiyoharu
    CARBON, 2021, 178 : 822 - 822