Shaking table tests on a full-scale unreinforced and IMG-retrofitted clay brick masonry barrel vault

被引:0
|
作者
V. Giamundo
G. P. Lignola
G. Maddaloni
F. da Porto
A. Prota
G. Manfredi
机构
[1] University of Naples Federico II,Department of Structures for Engineering and Architecture
[2] University of Benevento “Sannio”,Department of Engineering
[3] University of Padua,Department of Civil, Environmental and Architectural Engineering
来源
关键词
Barrel vaults; Seismic performance; Shaking table test; Dynamic identification; Dynamic characteristics; Masonry buildings; Retrofit; IMG;
D O I
暂无
中图分类号
学科分类号
摘要
The recent earthquakes in Italy demonstrated the extreme vulnerability of historical and cultural structures. Masonry vaults, which represent artistically valuable elements of these constructions, have been recognised among the most vulnerable elements. Traditional vault retrofit methods, such as buttresses or ties, are still widely adopted. These retrofit methods prevent differential displacements between vault supports (e.g., abutments, masonry piers and loadbearing walls). However, the pier differential displacement is not the only vulnerability source for vaults, and in many cases, further retrofit interventions are needed. Innovative retrofit methods based on inorganic matrixes, such as IMG, are aimed to prevent hinge mechanism failures. Such methods are suitable to be applied on vaults already retrofitted using traditional methods. The knowledge of the seismic behaviour of a vault, once the differential displacement between the supports is prevented, can be crucial to the assessment of potential further vulnerabilities of vaults already retrofitted with traditional methods. However, a deep knowledge of vault seismic behaviour is still lacking from an experimental point of view. Indeed, to date, few dynamic experimental studies have been conducted. Therefore, to investigate the seismic behaviour of masonry barrel vaults, several shaking table tests were performed on a full-scale specimen before and after the retrofit interventions. The tests investigated the main seismic properties of the tested structure and clarified the cracking mechanisms and capacity improvement due to the retrofit interventions. A comprehensive overview of the main results of the experimental tests has been presented.
引用
收藏
页码:1663 / 1693
页数:30
相关论文
共 50 条
  • [41] Full-Scale Shaking Table Tests on a Substandard RC Building Repaired and Strengthened with Post-Tensioned Metal Straps
    Garcia, Reyes
    Hajirasouliha, Iman
    Guadagnini, Maurizio
    Helal, Yasser
    Jemaa, Yaser
    Pilakoutas, Kypros
    Mongabure, Philippe
    Chrysostomou, Christis
    Kyriakides, Nicholas
    Ilki, Alper
    Budescu, Mihai
    Taranu, Nicolae
    Ciupala, Mihaela Anca
    Torres, Lluis
    Saiidi, M.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (02) : 187 - 213
  • [42] Shaking table tests and seismic assessment of a full-scale precast concrete sandwich wall panel structure with bolt connections
    He, Jia-Xuan
    Xu, Zhao-Dong
    Zhang, Lian-Yu
    Lin, Zhi-Hua
    Hu, Zhong-Wei
    Li, Qiang-Qiang
    Dong, Yao-Rong
    ENGINEERING STRUCTURES, 2023, 278
  • [43] Verification of identification methods for linear systems utilizing shaking table tests of full-scale 4-story steel building
    Ikeda Y.
    AIJ Journal of Technology and Design, 2010, 16 (34) : 889 - 894
  • [44] Full-scale shaking table tests for assessment of functionality in medical facility: Evaluation of safety and functionality in city facility during earthquake
    Sato E.
    Sakai H.
    Fukuyama K.
    Furukawa S.
    Kamada T.
    Kakehi A.
    Kobayashi K.
    Inoue T.
    Nakashima M.
    Journal of Structural and Construction Engineering, 2010, 75 (650): : 771 - 780
  • [45] Shake-Table Tests of a Full-Scale Two-Story Shear-Dominated Reinforced Masonry Wall Structure
    Mavros, M.
    Ahmadi, F.
    Shing, P. B.
    Klingner, R. E.
    McLean, D.
    Stavridis, A.
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (10)
  • [46] Seismic Response Analysis Model for Full-Scale 10-Story RC Building of Shaking Table Tests (FY2015)
    Kang, Jae-Do
    Kajiwara, Koichi
    10TH INTERNATIONAL CONFERENCE ON FRP COMPOSITES IN CIVIL ENGINEERING (CICE 2020/2021), 2022, 198 : 1874 - 1882
  • [47] Verification of identification method for nonlinear hysteretic systems utilizing shaking table tests of full-scale 4-story steel building
    Ikeda Y.
    AIJ Journal of Technology and Design, 2010, 16 (34) : 895 - 898
  • [48] Shaking table tests of a full-scale 10-story reinforced-concrete building (2015). Phase II: Seismic resisting system
    Kang, Jae-Do
    Kajiwara, Koichi
    Tosauchi, Yusuke
    Sato, Eiji
    Inoue, Takahito
    Kabeyasawa, Toshimi
    Shiohara, Hitoshi
    Nagae, Takuya
    Kabeyasawa, Toshikazu
    Fukuyama, Hiroshi
    Mukai, Tomohisa
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2023, 52 (06): : 1932 - 1955
  • [49] Shaking table tests of a full-scale base-isolated flat-bottom steel silo equipped with curved surface slider bearings
    Furinghetti, Marco
    Mansour, Sulyman
    Marra, Matteo
    Silvestri, Stefano
    Lanese, Igor
    Weber, Felix
    Pavese, Alberto
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2024, 176
  • [50] Shaking table tests of a full-scale flat-bottom manufactured steel silo filled with wheat: Main results on the fixed-base configuration
    Silvestri, Stefano
    Mansour, Sulyman
    Marra, Matteo
    Distl, Johann
    Furinghetti, Marco
    Lanese, Igor
    Hernandez-Montes, Enrique
    Neri, Caterina
    Palermo, Michele
    Pavese, Alberto
    Parisi, Elisa Rizzo
    Sadowski, Adam Jan
    Selva, Francesco
    Taniguchi, Tomoyo
    Vadrucci, Laura
    Weber, Felix
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2022, 51 (01): : 169 - 190