Shaking table tests on a full-scale unreinforced and IMG-retrofitted clay brick masonry barrel vault

被引:0
|
作者
V. Giamundo
G. P. Lignola
G. Maddaloni
F. da Porto
A. Prota
G. Manfredi
机构
[1] University of Naples Federico II,Department of Structures for Engineering and Architecture
[2] University of Benevento “Sannio”,Department of Engineering
[3] University of Padua,Department of Civil, Environmental and Architectural Engineering
来源
关键词
Barrel vaults; Seismic performance; Shaking table test; Dynamic identification; Dynamic characteristics; Masonry buildings; Retrofit; IMG;
D O I
暂无
中图分类号
学科分类号
摘要
The recent earthquakes in Italy demonstrated the extreme vulnerability of historical and cultural structures. Masonry vaults, which represent artistically valuable elements of these constructions, have been recognised among the most vulnerable elements. Traditional vault retrofit methods, such as buttresses or ties, are still widely adopted. These retrofit methods prevent differential displacements between vault supports (e.g., abutments, masonry piers and loadbearing walls). However, the pier differential displacement is not the only vulnerability source for vaults, and in many cases, further retrofit interventions are needed. Innovative retrofit methods based on inorganic matrixes, such as IMG, are aimed to prevent hinge mechanism failures. Such methods are suitable to be applied on vaults already retrofitted using traditional methods. The knowledge of the seismic behaviour of a vault, once the differential displacement between the supports is prevented, can be crucial to the assessment of potential further vulnerabilities of vaults already retrofitted with traditional methods. However, a deep knowledge of vault seismic behaviour is still lacking from an experimental point of view. Indeed, to date, few dynamic experimental studies have been conducted. Therefore, to investigate the seismic behaviour of masonry barrel vaults, several shaking table tests were performed on a full-scale specimen before and after the retrofit interventions. The tests investigated the main seismic properties of the tested structure and clarified the cracking mechanisms and capacity improvement due to the retrofit interventions. A comprehensive overview of the main results of the experimental tests has been presented.
引用
收藏
页码:1663 / 1693
页数:30
相关论文
共 50 条
  • [21] Full-scale shake-table tests on two unreinforced masonry cavity-wall buildings: effect of an innovative timber retrofit
    Miglietta, Marco
    Damiani, Nicolo
    Guerrini, Gabriele
    Graziotti, Francesco
    BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (06) : 2561 - 2596
  • [22] Experimental seismic performance of a full-scale unreinforced clay-masonry building with flexible timber diaphragms
    Kallioras, Stylianos
    Guerrini, Gabriele
    Tomassetti, Umberto
    Marchesi, Beatrice
    Penna, Andrea
    Graziotti, Francesco
    Magenes, Guido
    ENGINEERING STRUCTURES, 2018, 161 : 231 - 249
  • [23] Shaking table tests for a full-scale model of a steel-timber composite structure
    Li, Guodong
    Luo, Jiayu
    Guo, Nan
    Zuo, Hongliang
    International Journal of Earth Sciences and Engineering, 2016, 9 (04): : 1700 - 1704
  • [24] Full-scale shaking table tests and numerical studies of structural frames with a hybrid isolation system
    Liu, Xiaotian
    Wang, Wei
    Li, Junlin
    ENGINEERING STRUCTURES, 2023, 292
  • [25] Seismic performance of small earth dams with sloping core zones and geosynthetic clay liners using full-scale shaking table tests
    Sawada, Yutaka
    Nakazawa, Hiroshi
    Oda, Tetsuya
    Kobayashi, Seita
    Shibuya, Satoru
    Kawabata, Toshinori
    SOILS AND FOUNDATIONS, 2018, 58 (03) : 519 - 533
  • [26] Biaxial shaking table tests on a full-scale single-storey traditional Greek stone masonry and timber-framed composite structure
    Panoutsopoulou, Lydia
    Mouzakis, Charalampos
    JOURNAL OF BUILDING ENGINEERING, 2024, 98
  • [27] Numerical modelling of the out-of-plane response of full-scale brick masonry prototypes subjected to incremental dynamic shake-table tests
    Malomo, Daniele
    Pinho, Rui
    Penna, Andrea
    ENGINEERING STRUCTURES, 2020, 209
  • [28] Quasi-static in-plane behavior of full-scale unreinforced masonry walls retrofitted using ferro-cement overlay
    Hasnat A.
    Ahsan R.
    Yashin S.M.
    Asian Journal of Civil Engineering, 2022, 23 (5) : 649 - 664
  • [29] Applied Element Modelling of the Dynamic Response of a Full-Scale Clay Brick Masonry Building Specimen with Flexible Diaphragms
    Malomo, Daniele
    Pinho, Rui
    Penna, Andrea
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2020, 14 (10) : 1484 - 1501
  • [30] Mathematical modeling and full-scale shaking table tests for multi-curve buckling restrained braces
    Tsai, C. S.
    Lin, Yungchang
    Chen, Wenshin
    Su, H. C.
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2009, 8 (03) : 359 - 371